Loading...
HomeMy WebLinkAboutMDC S202 STEEL DETAILS AND NOTESPLANIi STONE PER ARCH— 16 GAGE CLIP � EA. 5 f�STL EL. 18�-3'� H5510 PER PLAN PL 5/i6"xC01 B/BM. EL. 116'-3" GLASS PER ARCH. HSS PER PLAfJ� CHANNEL PER PLA�� L2x2x1/4xCONT� A B/BM. EL. Y' 109�_1 1�2• HS56 PER PLAN ROOF � H5514 w a �O �� I�I 4 � ExIST. BM. �EXIST. ROOF �� EXIST. JSTJ SECTION � 2� SECTION 2 2 Q t/z"m DETAIL 9 S2�1 IF THIS DIMENSION IS MORE THAN 4" ADD (2) — L2x2x3/i6 AS SHOWN. WELD TO TOP & BOTTOM CHORDS (FURNISHED & INSTALLED BY MECH. CONTRACTOR) NOTES: 1. SERVICE LOADS SHOWN ARE MORE CPoTICAL OF D+ L OR JS(D+L+W) OR D+JS(L+E) OR W—.9(D) OR E—.9(D) 2 CONNECTIONS SHALL BE DESIGNED FOR FORCE INDICATED ON ELEVATION. 3. ALL BOLTED CONNECTIONS SHALL BE "SLIP CRITICAL" CONNECTIONS RELEASED FOR CONSTRl1CTI0N Su6jec��o compliance with allregula�ions of Sla�e antl Local Codes City of Carmel �� `��¢m�' lamn�Ml1 � DATE: O1IZ1IZO TYPICAL ROOF OPENING DETAIL HARDWOOD BLOCKING IN DECK CELLS � 12" O.0 ,'._' ____. ._.'_' CURBS (B STEEI JOIST REINFORCING AT ROOF TOP UNIT CURBS NO SCALE ROOF DECK T STL EL. VARIES 1/Y'0 ERECTION BOLT ! ��/ � PER PER PLAN LL X � U Q � .� 5/8" \ f YP. \ f10N� �� DETAIL �o S201 [R PLAN ROOFlNG MATERIAL PER ARCH. DWGS. JST. PER SUMP PAN BY J LL3x3x1�4 FULL WEL�ED FRAME oECK suPPUER ROOF DRAIN SUPPORT DETAIL DBL ANGLE CONN.1 TO FlLL BM. WEB i ROOF & OVERFLOW DRAINS PER PLUMBING DWGS. DECK PER PLAN i/7'm EREcrioN so�r 5�8.. � � �� DETAIL �� s2o� PER PLAN STRUCTURAL SiEEL Detailing, fabrication and erection of structural steel shall be In conformance with the AISC Specification for Structural Steel Buildings, latest edltion with amendments, and the AISC Code of Standard Practice for Steel Buildings and Bridges, latest editlon with amendments. Rolled shapes shall conform to ASTM A992, Grade 50. Plates shall conform to A51M A36. iubing shall conform to ASTM A500, Grade B. Column anchor bolts shall conform to ASTM A36, unless noted otherwise. Rolled shapes and plates shall be shop—painted gray with a rust inhibiting primer, unless dlrected otherwise by the specification. Touch up all nicks and obrasions after erection is complete. Design connections not shown per the latest edition of the AISC Specification and Manual of Steel Construction. Bolted connections shall be made with 3/4" diameter bolts, conforming to ASTM A325, tightened to the enug tight condition, unlase noted otherwise. Bolted connections in wind broce elements shall be tightened using the tum—of—nut method. Connections shall conform to the Specification for Structural Joints Using ASTM A325 or A490 Bolts, approved by the Research Council on Structural Connections of the Engineering Foundotion. Welding of structural members shall be in conformance with the American Welding Society's (AWS) Structural Welding Codes foc Steel AN51/AWS D1.1, Sheet Steel AN51/AWS D1.3 and Reinforcing Steel AN51/AWS �1.4. iypical welded connections shall be made with E70XX electrodes. When ASTM A992 steel is used os a bose metal, E70XX Low Hydrogen electrodes sholl be used. Base moterial within 7' of any field weld shall be free of materials that would prevent proper weldinq or produce toxic fumes during welding operations. Splicing ot structural steel members is not permitted without prior approval of the Structural Engineer. STEEL DECK Supply and erect steel deck in conformance with the latest editlon of the Steel Deck Institute's Speciflcations and Code of Standard Practice. Deck supplier shall provide all roof deck and accessories required for a complete installotion. Such materials shall be shop painted with a rust inhibiting primer. Roof deck attachment shall be as directed on plan. Roof deck shall be attoched to continuous supports at 12�� o.c. along the building perimeter. Welding operations shall comply with the latest editlon of the American Welding Society's Structurol Welding Code —Sheet Steel ANSI/AWS D1.3. STEEL JOISTS Steel bar joists shall be designeQ fabricated and installed In conformance with the requirements of the latest Steel Joist Instltute (SJI) specifications. Steel bar joists shall be shop painted with a rust—inhibiting primer. Steel joists shall be designed and fabricated per loading information shown on plon. Live load deflection shall be limlted to the following: L/360 of the joist span Where connections for steel joists ore not shown or noted, provide connectlons as required by the SJI speciflcations. Horizontol and dlogonal bridging for steel joists shall be located and designed per the SJI specificotions. Bridging angles shall be welded to joist top and bottom chords and shall be positively attached at ends of joist bays as detailed on plan. Support all mechanical, electricol, plumbing and sprinkler systems at ponel points only. Otherwise reinPorce chord members per plan detoils. Point loads greater than 200 pounds must be reviewed by the Structural Engineer. If a column Is not framed In at least two directlons with steel beoms, then the joist nearest the column sholl be bolted to supporting members during erection. stEE� �oist ciROERs Steel joist girders shall be designed, fabricated and Installed in conformance with the requirements of the lotest Steel Joist Instltute (SJI) specifications. Joist girders shall be designed and fabricated per loading information shown on plan (self weight not included). When a girtler is designated with VG instead of G, joists must bear only at vertical Joist Girder web members. Live loatl tleflection shall be limited to the following: L�360 of the joist span Provide stablllzer plates on columns between the joist girder bottom chord members os required by Steel Joist Institute (SJI) epeciflcations. Where end connections for joist girders are not shown or noted, provide connecYions as required by the Steel Joist Institute (SJI) specifications. Joist Girder bracing shall be as indicated by the manufacturer and as requlred by the Steel Joist Institute (SJI) specifications. DESIGN DATA The structure was designed per the Indiana Building Code. RWF LOADS Live Load 20 psf Dead Load 20 psf fi SPA. � 6" = 3'-0" 5/8" DIA. PUDDLE �WELD � 17' O.C. ALONG suaaoRTEo EocEs 36/7 PATiERN ��a" oin. Puoo�E LD (iYP.) NorEs: 1) SIDELAP FASTENERS TO WNSIST OF 2—$10 TEK SCREWS PER SPAN 2) ALL ROOP DECK TO BE 22 GAGE TYPE B(WIDE RIB) METAL DECK 3) SUPPLY W SHEETS LENGTHS TO PROVIDE A MINIMUM 3—SPAN CONDITION TYPICAL ROOF DECK ATTACHMENT PATTERN N AL ; ,� � � 'a ���$ �-6'2 w � �3 � � �3 ��x€ - Certified By wiu ;Y NQ c^, * �PE60870367�: � ; �_�`.. n�s rc :�,4�; StNLtUfOI rn O N 0 � 0 � W o � � O Z � C W V � � O U Z � - w O / I \ �J� O A—^ o v / � W �' N ^� � IJ � � Z C O � Q � � IJ � O 1� � � � W N � Iss ... _o�.i� �wia o>. a_, . Job Number. Draiing Name: — �-���_s���.��, o.awm9 N�mee.: S202 � SEE PLAN Q IJST. SPACING PER PLAN I Q SEE PLAN Q EDGE OF I��I^CL PANEL POMT CURB