HomeMy WebLinkAboutMDC SF201 FOUNDATION DETAILS AND NOTESa v T II i PER ARCH� I 1/7'0x 8" TITEN HD ANCHORS � 37' O.C. (OR APPROVED EQUAL) STUDS & BRICK PER nRCH. SLAB PER PLAN FlN. FLR EL. PER PLAN z,_6 d e de 7-6" /�4 DOWEL �� � 24" O.C. aRa al ae PER 1�7' EXP. JOINT MATERIAL SIDEWALK PER CIVIL DWGS. � SLAB PER PLAN SLOPE � FIN. FLR. EL. PER PLAN a a d � PER PLAN Y e PER PLAN I z -6 ° I _RIGID MSULATION 2'-fi" /j4 DOWEL �` o RIGID MSULATION � PER ARCH. DWGS � 24�� � � � p PER ARCH. DWGS. (J U T , a "I PER PLAN SECTION � F201 I CL WL & FTG. COL. PER PLAN �I 1/2" ISOLATION JOINT RLL W/WNC. I i OR GROUT � rSLAB PER PLAN I/ RN. FLR. EL. �-c�. �::-��`� • ' • ��I t �•. ;. ,-�,•r r, ��r.. 'r aER P�aN T/FTG. EL � PER PLAN � � �. � I / SEE•THIS SHi FOR WL. FTG. PER PLAN J BASE SETTING DETAILS SECTION 4 F201 ERIST. 3.9 SEE PLAN CL WL. & FTG. I EXIST. SLAB I � FIN. FLR. EL � I PER PLAN . �. � ' �i } � � r. : � �. � I- � . i PER PLAN SECTION 2 F201 —f � � EXISTING CMU , .,� WALL 1�2° EXP. JOINT MATERIAL�,' .' SLAB PER PLAN� . rEX15T. SLAB FIN. FLR EL ! PER PLAN ,.�,� � � ��.. . � ..� '• � CONiRACiOR NOiE: �„ ALL EXISTING CONDITIONS . +. ARE TO BE FlELD VERIFIED PRIOR i0 FABRICA110N OR � CONSTRUCTION. �ExisriNc FTc. SECTION 5 F2�� FIN. FLR. ELA , PER PLAN t/Fic. E�. A PER PLAN 6" PL PER SCHEDULE- � � � I � COL PER PLAN I —H� � CONTRACTOR NOTE: � � a °� � e ' ALL EXISTING CON�ITIONS . � , e � ARE TO BE FlELD VERIFIEO ` � � PRIOR TO FABRICATION OR ° � ' CONSTRUCTION. . � � � ` � � ° . . . . � a BOT. FiG. EL. 10 MAiCH EXI511NG FXIST FTG.�� �DRILL & EPDXV fi" WTO ExISL FTG. SECTION 6 F2�� J aER P�nN PLAN SECTION COL. BASE DETAIL C�? EXIST ENTRIES NO SCALE DIM. PER ARCH. 1/7� EXP. JOINT MATERIAL •��/4 x 1• O••J � DETAIL AT DOOR JAMBS NO SCALE 3�4��0x16" SMOOTH 1/4" (f) SAWED OR BAR � 24 O.G COAT OR WRAP TO � PREMOLDED JOINT \ \ PREVENT 60N� o ol o f� JY','r' e,,�' r^�.,� •♦• I �I .-1 �-' r-' r' ... i—" ' I �I SLAB REMFORCING SLAB REWFORCING PER PLAN PER PLAN ' 'OINT CONTROL JOINT RELEASED FOR CONSTRl1CTI0N SuefeC� �� ��mo��a��e •��^ a�� re9��a����= L S L A B 0 N G R A D E J 0 I N TS of Sla�e antl Local Codes City of Carmel �� `��¢m�' lamn�Ml1 � DATE: O1IZ1IZO '�--I-' P� PER scHEou�E� � � `� I I � I � � � � � �� COL PER PLAN � CL WL & FTG. i COL PER PLAN � � i ��p" ISOLAiION JOIN1 I I I I SLAB PER PLAN i � FlN. FLR EL. RLL W/CONC. � � �;'� y.. r..r..r PER PLAN OR GROUT SEE THIS SHL FOR COL. BASE SE1iING DETAILS e � a e a• aml a ° a.n�. .'. � . d $. a � ' . �� a ad ' . � � e FTG. PER SHIMS & LEVELING NUTS Y� z � x F � � z o op rv� z 0 � i z� �� SHIMS & LEVELING I I � p NUTS I I a � . .:..... ..:.. . .. � Y� (4)_i•' DIA. x 1'_9•' � ANCHOR BOLTS (F1554 GR. 36) � � W� HEX NUTS & z o WASHERS � EA END o � �� PLAN SECTION TYP. COL. BASE DETAIL C�? BRACE NO SCALE � 1.. � 7.. z 2N_ _N2�� z o PL PER SCHEOULE-I I I I _� �"y � � I T-- � COL PER PLAN SHIMS & LEVELING � NUiS Y� z � x F � � z O o � z � �� SECTION 3 F201 i�wlw z 0 � w 'o G AN)CHOR BO TS% � -g (F1554 GR. 36) W/ HEX NUTS & WASHERS � EA. END �IA. x 1• 9•• ENo PLAN SECTION TYP. COL. BASE DETAIL NO SCALE T/FTG. EL. � PER PLAN . �2 � EXP. JT. A C WL PER . INTERIOR EXTERIOR TYPICAL COLUMN ISOLATION JOINTS NO SCALE GENERAL Reference Architecturol, Mechonlcal, Electrical, ond Plumbing drawinqs for openings, sleeves, curbs, inserts, etc. not herein indlcated. All sleeves or openinqs required in structural membere shall be approved by the Structural Engineer. The structure has been designed for the final, In-service condition. It shall be the contractor's responsibility through methods and means of construction to maintoin the integriTy of the structure during all stages of construction ond insure safe working conditions. The Controctor shall be responsible for preporation of shop drawings to enable fabricatlon, erection and construction oll parts of the work In accordance with the drawings ond specifications. Shop drawing review by the Structural Engineer shall be for design conformance only. The Contractor sholl be responsible for all dlmensions, acwracy, and fit of work. FouNonrioNs Eaterior foundations shall bear a minimum of 3'-0" below finish grade and shall bear on undisturbed soil. Allowable Soil bearing pressures: 1,500 psf Foundation excawtlons shall be made to plan elewtlons and inspected by a qualifled Geotechnlcal Engineer. Soil mnditions found to be unacceptable shall be modifled by one of the following procedures: 1. Remove all unacceptable soil and replace with compacted material as directed by the Geotechnical Engineer. 2 Lower foundations to an acceptable level and install concrete pedestals as directed by the Structural Engineer. Foundation excavatlons shall be compacted to a level surfoce (or formetl where soil conditions do not allow). The excavation shall be protected from weather if concrete plocement tloes not occur within 24 hours of excavation of the footing. CONCRETE Reinforcetl concrete has been designed In conformance with the Builtling Code Requirements for Structurol Concrete (ACI 318) and Commentary (ACI 318R). Concrete mlxing, transporting, and placing shall be in accordance with the latest edltion of the Specifications for Structural Cancrete for Buildings (ACI 301). Concrete listed below shall be proportioned with sand fine aggregate and narmal weight caorse oggregates (ACI 302.16) and Type I Portland rement (ASTM C150). Compressive strength (Pc) at 28 days shall conform to the following: Spread footings and wall footings 3,000 psi Sidewalks and exterior slabs 4,000 psi ( 6%+/-1% air entroinment) Slobs on grode 4,000 psi Slob on qrade construction shall be in conformance with the latest edition of the Guide for Concrete Floor and Slob Constructlon (ACI 3021R) and the following minimum requirements: Minimum cement content (mtenor uses) 5 sacks/cys Minimum cement content (exterior uses) 6 sacks/cys Maximum w�c raho (mtenor uses) 048 Maximum w/c roho (extenor uses) 0 45 Maximum slump pnor to addihon of plashc¢ers 3'mches Maximum slump if plastiazers ore not used 4 inches (measured at point of discharqe from pipe) Do not finish surface until roncrete has lost surfare water sheen or all free water. Do not sprinkle cement on the slab surface. Concrete slabs shall be cured immediately after finishing using a sprayed on liquid curing rompound or other methods approved by the Structural Engineer. Compressive strength tests shall ronform to the requlrements of ASTM C39. Specimens shall be taken in acmrdance with the latest edition of ASTM C3L Each set shall indude one cylinder tested at 7 days, 2 cyllnders tested at 28 days and one cylinder retained in reserve. Test resWts shall be forwarded to the Structural Engineer for review and comment. Protect the ronnete surfare from precipitation and on hot, dry, windy days use wet burlap, plastic membranes or fogging. Construction joints between pours shall be prepared by roughening the rontact surface to an amplitude of opproximately 1/4 'mch, removing oll surface laitonce. The contractor shall submit mix desi9ns for each proposed closs of concrete for the Structurol Engineer to review. RBNFORCING STEEL Reinforcing steel shall be deformed bars of new billet steel with o minimum yield strength of 60,000 psi conforming to ASTM A615. Detailing, fabricoting, and placin9 of reinforcement shall be In occordance with the latest edition of the following standards: Specifications far Structural Concrete for Bulldings (ACI 301), ACI Detailing Monual(SP66). Reinforcing bars shall not be welded, heated or cut unless shawn on the cantract dacuments. Welded wire fabric shall be smooth wire fabric (ASTM A785), supplied in flat sheets. Welded wire fabric shall be placed 2" down from the top of the slab for slabs on grade and lapped a minimum of 14 inches on all sides. Concrete cover shall be as speafied in the latest etlition of ACI 318 unless notes otherwise on plan. Use standard bar chairs and spacers to maintain concrete protection speafied. Spllcing of reinforcing bars shall conform to latest edition of ACI 318. Use a Class ��B" lap at splices unless Indicated elsewhere. GROU1 FOR COWMN BASEPLAIES Grout for column base plotes shall be o nonmetallic, nan-shrink grout (comptying with the requirements of ASTM C827 or CRD-C621), premixed, norrorrosive, non-staining product rontaining Portland Cement, silica sands, and fluidity improving compounds. Minimum compressive strength (f'c) at 28 days shall be 4,000 psi. Compressive stren9th tests shall conform to the requirements of ASTM C709. ti � .� � � L ���g � � � ���€ - � I_- `��plllllll �� �S P SCH ��. eEc�sr[xco ,�P No , A� � . PEs�%Q�) : # _ 9 �-�.. n�rz rc �4�, Structural rn c� � � :, �Z� ,, � ,� _ <�'. _: 1� W � - Z W - V Z^ V v / � Z — � � I'� W - � a.���:�.,r. _,,,�.� v,:,��,: ��ou��vrio� �.JI � .IG R NOI I S F2(� 1