HomeMy WebLinkAboutE100.00 Electrical Cover SheetRELEASED FOR CONSTRl1CTI0N
Su6jec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
y�,:�v��� �'�a;,v��tiw� �
\
DATE: O��Z��ZO
NAME� LEVELNAME O— INDICATESNOTEUSEDTODESCRIBE
� 10'-0"— HEIGHTABOVE ADDITIONALMFORMATIONABOUT
PROJECTO'-0" WORKREpUIRED,SPEQFlCTOTHE
SHEET AND/OR DETAIL
INDICATES DIRECTION OF TRUE NORTH
PLAN OR DETAIL Nl1M6ER
PLAN OR DETAIL NAME
/\ - VIEW NAME
/ , � „8. _ ,�`.
PLAN OR DETAIL SCALE
�RS
— INDICATES SIM ILAR DETAIL
SIM � REFERENCED IN Ml1LTIPLE LOCATIONS
�A' � DETAIL REFERRED TO BV SECTION CUT
- �.
`, M101 .� SHEET DETAIL IS LOCATED ON
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
SIM
� DETAILREFERREDTOBVELEVATION
� 4 � 7f......
o� T101�SHEETDETAILISLOCATEDON
LME TVPE KEV:
NEW WORK BV THIS CONTRACTOR
--------- (DARKSOLIDLINE)
NEW WORK UNDERFLOOR OR UNDERGROUND BV THIS CONTRACTOR
(DARK LONG DASHED LINE)
NEW WORK BY OTHERS ANDIOR EXISTING TO REMAIN
(LIGHT SOLID LME)
- EXISTINGTOBEREMOVEDBYTHISCONTRACTOR
(DARK SHORT DASHED LINE)
CONTRACTOR SHALL COMPLV W ITH APPLICABLE CODES AND LOCAL AM ENDMENTS.
DINGCODE INDIANABUILDINGCODE WITHAMENDMENTS
2014 EDITION
CODE INDIANAFlRECODE WITHAMENDMENTS
2012 EDITION
SAFETYCODE NFPA1012012EDITION WITHAMENDMENTS
1ANICALCODE INDIANAMECHANICALCODE WITHAMENDMENTS
2014 EDITION
'.TRICALCODB IEC2009EDITION WITHAMENDMENTS
(NFPA ]Od008)
1BMGCODE INDIANAPLUMBMGCODE WITHAMENDMENTS
2012 EDITION
CODE: INDIANAFIRECODE WITHAMENDMENTS
2014 EDITION
iSSIBILITY CODE: INDIANA BU ILDMG CODE CHAPTER-11 W ITH AMENDMENTS
2014 EDITION
ATORCODE: ASME1�.3-2005,ASMEQEI-1-200� WITHAMENDMENTS
ANSI/ASCE/T8 Di 21-OS
2GYCODE: INDIANAENERGYCONSERVATION WITHAMENDMENTS
CODE 2010
°RAPPLICABLECODB 2001AIAGUIDELINES
SYMBOL:
O
�
0
�
0
O
SYMBOL:
�
�
�
�
C#
v
ELECTRICAL SYMBOL LIST
TAG: ^ SPEC' DESCRIPTION:
ECONN
JB
PANEL'#k#'
CB-k
ELECTRICAL SYMBOL LIST
TAG: SPEC DESCRIPTION:
. SECTION: .
REC-Dl1P 262]26 Dl1PLEXRECEPTACLE,125V
REC-Dl1P-GFl 262]26 Dl1PLEXGFIRECEPTACLE,125V
REC-QUAD 262]26 QUAD RECEPTACLE,125V
REC-QUAD-GFl 262]26 QUAD GFIRECEPTACLE,125V
WALL MOUNTED DATA OUTLET
260533 ELECTRICALCONNECTION
Y{;p�,Xg�111�[NIP1J:i0.�
262416 PANELBOARD-Sl1RFACEMOl1NT
262816 CIRCWTBREAKER-Sl1RFACEMOl1NTED.
REFER TO DISGSTA SCHEDULE
SYMBOL:
$
D
OC
$p
TAG:
SW-iP
SW-D-LED
SW-OC-D
SW-OC-P-O
SPEC DESCRIPTION:
SECTION:
260933 SWITCH-SINGLEPOLE
260933 DIMMER
260933 OCCUPANCVSENSOR-DUALTECHNOLOGV
260933 SWITCH-OCCUPANCVSENSOR
WALL SW ITCH
SYMBOL:
�
❑
�
O
TAG: SPEC DESCRIPTION:
SECTION:
LINEAR WMINAIRES
TROFFER
REFER TO LUMINAIRE
SCHEDl1LE WALLSCONCE WMINAIRE
DOWNLIGHT WMINAIRE
ELECTRICAL SYMBOL LIST
SYMBOL: TAG: SPEC DESCRIPTION:
SECTION:
SD FA-120 283100 FIREALARMSMOKEDETECTOR-CEILING
MOUNTED
O FA=130 2831 00 FlRE ALARM MANUAL PULL STATION
A� A3 FA-211 283100 FIREALARMAl1DIOlVISl1ALNOTIFICATION
A� AH DEVICE-WALLMOUNTED
AS
ABBR:
A.C.
A.T.C.
A V.C.
C.C.
C.M.
E.C.
FP.C.
F.S.C.
G.C.
H.C.
M.C.
N.GC.
P.C.
$.C.
T.C.
T.GC.
V.C.
CONTRACTOR ABBREVIATION KEY
DESCRIPTION:
ASBESTOSABATEMENTCONTRACTOR
AUTOMATICTEMPERATURECONTROLCONTRACTOR
AUDIONISUAL CONTRACTOR
CNIL CONTRACTOR
CONSTRUCTIONMANAGER
ELECTRICALCONTRACTOR
FIRE PROTECTION CONTRACTOR
FOOD SERVICE CONTRACTOR
GENERALCONTRACTOR
HEATING CONTRACTOR
MECHANICALCONTRACTOR
NURSECALLCONTRACTOR
PLUMBING CONTRACTOR
SECURITV CONTRACTOR
TECHNOLOGVCONTRACTOR
TEMPERATURECONTROLSCONTRACTOR
VENTILATION CONTRACTOR
ELECTRICAL RENOVATION NOTES:
THESE NOTES APPLV TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOT LIM ITED
TQ LIGHTING, POWER, AND SVSTEMS-
1. EXISTING CONDITIONS ARE SHOW N BASED ON INFORMATION OBTAINED FROM FIELD
SURVEVS, EXISTING BWLDING DOCUMENTS, AND STAFF. VERIFV EXISTING CONDITIONS AND
REPORT ANY CONFLICTS BEFORE PROCEEDMG.
2. NOTALLEXISTINGEpUIPMENT,LUMINAIRES,ANDCONDUITARESHOWN. VERIFYEXISTING
CONDITIONS AND REPORT ANY CONFLICTS W ITH NEW WORK BEFORE STARTING WORK.
3. FlELD VEPoFY THE AVAILABLE CLEARANCES FOR CABLE TRAY, BUSWAY AND CONDUITS
BEFORE FABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING
FIELD CONDITIONS.
4 EACHCONTRACTORSHALLFlELDVERIFYACCESSIBILITYTOTHEAREAOFHIS/HERWORK
AND SHALL NOTIFV THE CONSTRUCTION MANAGER PRIOR TO BIDDING IF OTHER UTILITIES
ARE REQl11RED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO HISIHER AREA OF
WORK.
S THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, REMOVAL AND PATCHING OF
ROOFS, WALLS, AND FLOORS ASSOCIATED W ITH W ORK BV ALL CONTRACTORS.
CONTRACTORS SHALL NOTIFV THE GC OF AFFECTED AREAS PRIOR TO BIDDMG.
6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF
CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED W ITH AREAS OF W ORK BY ALL
CONTRACTORS. NOTIFV THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR TO
BIDDING.
]. WHERE EXISTING ELECTRICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT W ITH NEW
EQUIPMENT, PIPMG, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER
ARRANGE NEW E�UIPMENT, CONDUIT, OR DUCPNORK IN SUCH A FASHION THAT IT DOES
NOT CONFLICT W ITH EXISTING SYSTEMS, OR REWORK EXISTING ELECTRICAL SYSTEMS TO
ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK.
ELECTRICAL ABBREVIATION KEY
ABBR: DESCRIPTION:
AFF ABOVE FINISHED FLOOR
C CONDWT
GFl GROUNDFAULTIMERRUPTER
N.C. NORMALLYCLOSED
NIC NOT IN CONTRACT
N.O. NORMALLYOPEN
SV SOLENOID VALVE
TYP TYPICAL
UNO UNLESSNOTEDOTHERWISE
SYMBOL:
� �
� �
� 0
LUMINAIRE SYMBOL KEY
DESCRIPTION:
NORMAL BRANCH LUMINAIRE
CRITICAL BRANCH LUMINAIRE
LIFE SAFETY BRANCH LUMINAIRE
2�" MAX � 2�" 25" MAXx '�
/ � I
� � ��
L i � � L� � �
� � � � O�
� ��� �� �
' �r'�'�•' . I. `-�— l`1�"-' � I.
l l
ELECTRICAL GENERAL NOTES:
1. ##-###INDICATESELECTRICALE�UIPMENTDERNEDWELECTRICALSCHEDULESOR
SPECIFICATION. REFER TO DRAW MGS CONTAINMG ELECTRICAL SCHEDULES. PERMANENT
NAMEPLATE SHALL MATCH FlNAL WUIPMENT NOMENCLATURE, NOT ELECTRICAL
EQl11PMENTTAG NAME, REFER TO SPECIFICATIONS.
2 "NL"INDICATESWMINAIREISUNSWITCHEDFORNIGHTLIGHT.
3. SHADED LUMINAIRE OR DEVICE INDICATES LUMINAIRE OR DEVICE IS CONNECTED TO AN
EMERGENCY CIRC W T.
LUMINAIRE KEY:
� F1=FIXTURETAG
1 =CIRCUITNUMBER
WMINAIRE a=SWITCHDESIGNATION
NL = SUBSCRIPT QF APPLICABLE)
'IF LABEL IS ORIENTED HORIZONTALLY A SLASH W ILL SEPARATE THIS
INFORMATION. EX: F1 I 1 I a I NL
DEVICE KEY:
DEVICE� A-MOUNTINGQFAPPLICABLE)
1 = CIRCUIT NUMBER
'IF LABEL IS ORIENTED HORIZONTALLV A SLASH W ILL SEPARATE THIS
MFORMATION. EX: A / 1
ELECTRICAL MOUNTING SUBSCRIPT KEY:
A MOUNTAT+6"TOCENTERLINEABOVECOUNTERORBACKSPLASH
C MOUNTATCEILMG
H MOl1NTORIENTEDHORIZONTALLY
L MOUNT IN CASEWORK
M MOUNT IN MODULAR FURNITURE
R MOl1NTINSl1RFACERACEWAY
EWC ELECTRIC WATER COOLER
ELECTRICAL INSTALLATION NOTES:
1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE W ITH THE ADA STANDARDS FOR
ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS
ON THIS PAGE FOR ADDITIONAL INFORMATION.
2. CIRCUITNUMBERSARESHOWNFORCIRCUITIDENTIFlCATION.CIRCUITINGSHALLAGREE
W ITH Nl1M BERING ON THE PANEL PROVIDED. COMMON NEl1TRAL5 MAY NOT BE 115ED FOR
BRANCH CIRCUITS. BALANCE THE LOAD ON PANELAS EVENLY AS POSSIBLE BETWEEN
EACHPHASE.
3. LIFE SAFETV, CRITICAL, AND EQl11PMENT BRANCH WIRING FOR FEEDERSAND BRANCH
CIRCUITS SHALL BE ROUTED IN SEPARATE RACEWAY, JUNCTION BOXES, PULL BOXES, AND
CABMETS. WIRING FOR EACH BRANCH SHALL BE INDEPENDENT FROM OTHER BRANCHES,
INC W DING THE NORMAL BRANCH.
4. FLUSHMOUNTALLLIGHTMGCONTROLDEVICESAT+46"FROMFLOOR(CENTERLINE
DIMENSION), EXCEPT WHERE OTHERWISE NOTED. DEVICES MAV BE SURFACE MOUNTED
W HEN CONDWT IS SPECIFIED EXPOSED.
5. FWSHMOUNTALLDUPLEXRECEPTACLESANDTECHNOLOGVOUTLETSAT+18"FROM
FLOOR�CENTERLMEDIMENSION),EXCEPTWHEREOTHERWISENOTED. RECEPTAQESAND
OUTLETS MAY BE SURFACE MOUNTED WHEN CONDWT IS SPECIFIED EXPOSED.
6. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL
BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF
THROUGH-PENETRATION FIRESTOPS. REFER TO DNISION ] FOR ADDITIONAL INFORMATION
AND REQUIREMENTS SPECIFIC TO FIRESTOPPING.
1. CONTRACTOR SHALL COORDINATE THE LOCATION OFALL CEILING MOUNTED DEVICESAND
EpU IPMENT W ITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES
IN CEILING TILE PATTERN. SMOKE DETECTORSAND OCCUPANCVNACANCV SENSORS
SHALL BE LOCATED NO CLOSER THAN 3 FEET TO AN AIR SUPPLY DIFFUSER OR RETURN
�R���E.
8. CONTRACTORSHALLVERIFVALLFURNITURE,MODULARFURNITURE,ANDEQUIPMENT
LOCATIONS W ITH ARCHITECTU RAL PLANS, ELEVATIONS, AND REVIEW ED SHOP DRAW MGS.
PRIOR TO MAKING THE ACTUAL ELECTRICAL INSTALLATION, THIS CONTRACTOR SHALL
ADJl15T RECEPTACLES, Ol1TLET5, OR CONNECTION LOCATIONS TO ACCOMMODATE
FURNITURE AND/OR EQUIPMENT.
9. ELECTRICALANDTECHNOLOGYEpUIPMENTSHALL6EMOUNTEDTOAVOIDIMPEDANCEOF,
OPERATIONOF,ANDIORACCESSTOELECTRICALANDMECHANICALEQl11PMENT. ALL
MOUNTMG OF ELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT, ON EQUIPMENT
SUPPLIED BV ANOTHER CONTRACTOR, SHALL BE APPROVED IN ADVANCE BV THE OTHER
CONTRACTOR.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL
OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BV A �UALIFlED CONTRACTOR AT THE
EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR
SEALED INTO OPENINGS.
11. ALL WELDING SHALL BE ACCORDING TO AMERICAN WELDING SOCIETYSTANDARDS.
CONTRACTOR SHALL FURNISH TO THEARCHITECT/ENGMEER CERTIFlCATES pUALIFYING
EACH W ELDER, PRIOR TO START OF W ORK. THE ARCHITECT/ENGINEER RESERVES THE
RIGHT TO R W UIRE �UALIFYMG DEMONSTRATION, AT THE CONTRACTOR'S EXPENSE, OF
ANY W ELDERS ASSIGNED TO THE JO6.
12. CONTRACTORSHALLREMOVEANDREINSTALLALLCEILMGTILESASREQUIREDFORTHE
EXECUTION OF ELECTRICAL WORK. CONTRACTOR SHALL REPLACE CEILMG TRES W ITH
IDENTICAL MATERIAL WHERE DAMAGED BYTHIS CONTRACTOR.
13. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGV
AUDIONISUAL, AND OTHER ELECTRICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING
MOUNTED DEVICES, OTHER THAN SPRINKLERS.
14. ELECTRICALIDENTIFICATION. REFERTOSPECIFICATIONSECTION260553FOR
COLOR/LABELREQUIREMENTSFOR CONDUIT,BOX,CABLE/WIRE,ANDEQUIPMENT.
� A
/
/ l,
I�.P! � � i
to I z
—� �
� � � �
INSTALL ABOVE COUNTER INSTALL ABOVE COUNTER INSTALL DEVICE AT 18"
DEVICEAT44"ABOVE DEVICEAT40"ABOVE ABOVEFINISHEDFLOOR.
FINISHED FLOOR. FINISHED FLOOR.
ADA GUIDELW ES - FRONT ACCESS
1 �/'I� ,'� � -
¢ ¢
1 I
NFI I I}. � � �
� � �� �
Ir
� � ��� �
� �
10" MAX. 10"-24" MAX.
INSTALLDEVICEAT44" INSTALLDEVICEAT42"
ABOVE FINISHED FLOOR. ABOVE FINISHED FLOOR.
ADA GUIDELW ES - SIDE ACCESS
ADA STANDARDS FOR ACCESSIBLE DESIGN
�:I M EG r'nwec�Po+�mos+z� m=m' u
imrscoava�avesvaovaiErurvai�swcwowecowai�w qrorws
wsnawrv.rvcecar� suooewwirvearvaae .waae
rHE ExcwsvE PAOPmrr oFin�cccoAP nrvo sHnLL rvor eE �sm oA
aeva000ceo Fou uw o*neR ^�waesca� �x V r me exmesswamem qp
� Q
m 9
aQ 'm
u
0
a� N
a oC U
ai °J 3 a' `�
R � o �
���d�
x
� o'' a
' _ �i"
_ -= os=
o `- 5 - '
' o�.
_ -=-moa�oso o�
�.��o�a.,a�_a., �a
3 _y ��mm.�� q.Gb4 I
f ,/�±'
i.e__ ... .���
�� �. �9
g '+°m�°m
��2�13�19
�Hll/�IIIIIIIIIINl1h��� �
� � ���
REVISIONS
J
W
�
a
U
2
F
Q
W
i
Z
Q
U
N
U
� �
Z LL
�C.�..� R
C �
�.�..� a F
V � NZ
� ? Q
� W 0
W Z W
� J � �
2
W
� Z � �
J V Z ?
W y m �
Q�oo�
W
U LL � �
0
0
� �
m
�
��
m
U
� L
w
� R m�
il
Q
ELECTRICAL
COVERSHEET
E0.00