Loading...
HomeMy WebLinkAboutP100.00 Plumbing Cover SheetRELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel y�,:�v��� �'�a;,v��tiw� � \ DATE: O��Z��ZO VIEW KEY �NAME� LEVELNAME O-� INDICATESNOTEUSEDTODESCRIBE 10'-0"� HEIGHTABOVE ADDITIONALINFORMATIONABOUT PROJECTO'-0" WORKREQUIRED,SPECIFICTOTHE SHEETAND/OR DETAIL -INDICATES DIRECTION OF TRUE NORTH PLAN OR DETAIL NUMBER ��� -PLANORDETAILNAME , ' �- VIEW NAME 'Yp R � �, -PLAN OR DETAILSCALE INDICATES SIMILAR DETAIL SIM �� REFERENCED IN MULTIPLE LOCATIONS �-DETAIL REFERRED TO BY SECTION CUT 1 `�M101+ SHEETDETAILISLOCATEDON INDICATES SIMILAR DETAIL SINC� �� REFERENCED IN MULTIPLE LOCATIONS � DETAILREFERREDTOBVELEVATION f4� 2�� �:- �. T101- SHEET DETAIL IS LOCATED ON LINE TVPE KEV: NEW W ORK BY THIS CONTRACTOR (DARK SOLID IJNE) NEW W ORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR (DARK LONG DASHED LINE) NEW WORK BV OTHERSAND/OR EXISTWG TO REMAIN (LIGHT SOLID LINE) -------EXISTWG TO BE REMOVED BV THIS CONTRACTOR (DARK SHORT DASHED L WE) CONTRACTOR ABBREVIATION KEY Ia� -1-1:� �] X-YN :71 � I bl : F L��aR9Ni.YDSYilNil1��41�JOIHJI:L[N[H:i G\��ffp[H�dG\IPl1��dIJ�:�9lll:i=RHJCi�1IKHJI:L[NDI:i A.V.C. AUDIO/VISUALCONTRACTOR GG CNIL CONTRACTOR C.M. CONSTRUCTION MANAGER EG ELECTRICALCONTRACTOR FP.C. FlREPROTECTIONCONTRACTOR FS.C. FOODSERVICECONTRACTOR G.C. GENERALCONTRACTOR H.C. HEATING CONTRACTOR M.C. MECHANICALCONTRACTOR N.GC. NURSE CALL CONTRACTOR P.C. PLUMBING CONTRACTOR S.G SECURITYCONTRACTOR T.G TECHNOLOGVCONTRACTOR T.GG TEMPERATURECONTROLSCONTRACTOR V.C. VENTILATION CONTRACTOR I���l��i1-31►[�y'/��il-��l��6�1 NOT ALL SVMBOLS MAV APPLV. SYMBOL: DESCRIPTION: -AV- ACID VENT -AW- ACID WASTE -CA- COMPRESSEDAIR -CW- COLDWATER-POTABLE -D- DRAIN -DI- DEIONIZED WATER -DT- DRAW TILE -G- NATURALGAS -GRV- GASREGULATORVENT -GSAN- SAMTARV DRAINAGE (GREASE SAMTARV DRAINAGE) -GV- GREASE VENT -HW- HOTWATER-POTABLE -HWC- HOTWATERCIRCULATING-POTABLE -HW140- HOTWATER-POTABLENUMBERINDICATESTEMP -HWC140- HOTWATERCIRC.-POTABLENUMBERINDICATESTEMP -IA- -MA- -MV- -N- -NCW- -NHW- -NO- �R- -OS- -O- -p- -PD- -pW- -RO- -SAN- -SCW- -SHW- -ST(1,000)- -STS- -STW- -rw- -V- -VAC- -y�- -WAGD- 7 �F� � RD-1 6"�1000) �� �I� �� �� �GPM �'�� � Q� _-I ^ �� � � rL•J 4 1f 4 1l 4 �� �j Un1 M INSTRUMENT AIR MEDICALAIR MEDICAL VACUUM NITROGEN NON-POTABLE COLD WATER NON-POTABLE HOT WATER MTROUS OXIDE OIL RETURN OIL SUPPLV OXVGEN PROPANEGAS PUMPED DISCHARGE PURE WATER REVERSE OSMOSIS WATER SANITARV DRAINAGE SOFT COLD WATER SOFT HOT WATER STORM DRAINAGE (ROOF SQUARE FOOTAGE) STORM DRAINAGE (SECONDARV) SOFT TEMPERED WATER TEMPERED WATER VENT LABVACUUM SERVICE WATER - POTABLE WASTE ANETHESIA GAS DISPOSAL PIPE CONTINUATION PIPE CAP PIPE DOW N PIPE UP OR UP/DOWN PIPE SERVING FlXTURE ON FLOOR ABOVE (EXAMPLE: FD = FLOOR DRAIN) PITCH PIPE IN DIRECTION DIRECTION OF FLOW IN PIPE ROUTE TO DRAIN ROOF DRAIN PROPERTIES SVMBOL SIZE (ROOF S�. FTJ NEW CONNECTION DIELECTRIC CONNECTION UNION/FLANGE SHUTOFF VALVE NORMALLV OPEN SHUTOFF VALVE NORMALLV CLOSED BALANQNG VALVE (NUMBER INDIGATES GPM) CHECK VALVE SOLENOID VALVE SAFETV/RELIEF VALVE VACUUM BREAKER PRESSURE GAUGE (FURNISHED WITH BALL VAWE) PRESSURE SENSOR (FURNISHED WITH BALL VALVE) TEM PERATURE SENSOR W ITH W ELL THERMOMETER WITH WELL (DIAL TYPE) THERMOMETER WITH WELL (FlLLED TYPE) REDUCER-REFERENCESPECIFlCATION FOR CONCENTRIC/ECCENTRIC AND FOT/FOB PRESSURE REDUC W G VALVE (LIQUIDIGAS) PUMP METER ALIGNMENTGUIDE PIPE ANCHOR EXPANSION JOINT PLUMBING ABBREVIATION KEY ABBR: I DESCRIPTION: AD AFF BFP BT CB CI CO CS DB DF DI E EE ES ESE EWC FCO FD FM FS GD GI HB I E. LAV MB MH MV NC NIC NT OS RD SH SK ss TD TP TVP UR VTR WC WCO WF WH WMF WM WS UB UNO VCO ACCESSDOOR ABOVE FINISHED FLOOR BACKFLOW PREVENTER BATHTUB CATCH BASIN CASTIRON CLEANOUT CLINICAL SINK DIALVSIS BOX DRINKING FOUNTAIN DUCTILE IRON EXISTING EMERGENCVEVEWASH EMERGENCVSHOWER EMERGENCV SHOWER/EVEWASH ELECTRIC WATER COOLER FLOOR CLEANOUT FLOOR DRAIN FLOW METER FLOOR SWK GARBAGE DISPOSER GREASE WTERCEPTOR HOSE 6166 INVERT ELEVATION (FOR REFERENCE ONLV) LAVATORV MOP BASIN MANHOLE MIXING VALVE NEW CONNECTION NOTINCONTRACT NEUTRALIZATION TANK OIL SEPARATOR ROOF DRAIN SHOWER SINK SERVICE SWK TRENCH DRAIN TRAP PRIMER TVPICAL URINAL VENTTHROUGHROOF WATER CLOSET WALL CLEANOUT WASH FOUNTAIN WATER HEATER WASHWG MACHINE FIXTURE WATERMETER WATERSOFTENER UTILITV BOX UNLESS NOTED OTHERWISE VARD CLEANOUT PLUMBING GENERAL NOTES: L THESVMBOLSANDTHEMATERIALLISTAREFORTHECONVENIENCEOFTHECONTRACTOR. CONTRACTOR SHALL VERIFV QUANTITIESAND FURNISH ALL MATERIALS REQUIRED FOR FULLV OPERATIONAL SVSTEMS, WHETHER SPEQFlED OR NOT. 2. CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE, BUTARE GIVEN AS AN AID TO THE CONTRACTOR AND TO INDICATE THE QUALITV REQUIRED. CONTRACTOR IS RESPONSIBLE FOR A COMPLETE DESCRIPTION OF MATERIAL ON THESE DRAW WGS AND IN THESPECIFICATIONSBEFOREORDERING. THEDESCRIPTIONOFTHEMATERIALTAKES PRECEDENCE OVER THE CATALOG NUMBER. THE FIRST MANUFACTURER LISTED IS THE BASIS OF DESIGN. 3. CONTRACTORSHALLVERIFYTHATFlXTURESSUPPLIEDAREAPPROVEDPERALL APPLICABLE STATE, LOCAL AND GOVERN W G AUTHORITIES. 4. ALLFIXTURESSHALLCONFORMTOFEDERALACTS.38�4 5. REFERTOTHEPWMBINGROUGH-INSCHEDULEFORTHESIZESOFBRANCHPIPESTO PLUMBING FIXTURES. 6. FORCLARITV,NOTALLVALVESHAVEBEENSHOWN.PROVIDESHUTOFFVALVESIN DOMESTIC WATER PIPING SERVING EACH ROOM WITH FIXTURES. ANGLE STOPS SHALL NOT BE CONSIDERED SHUTOFF VALVES. �. EXISTWGCONDITIONSONDEMOLITIONPLANSAREPROVIDEDTOINDICATETHEGENERAL SCOPE OF ITEMS TO BE REMOVED. REFER TO SPECIFlCATION SECTION 22 OS OS FOR ADDITIONAL DEMOLITION INFORMATION. 8. P.C. SHALL CUT AND PATCH EXISTWG AS REQUIRED FOR NEW OR DEMOLITION W ORK UNLE55 NOTED OTHERWISE REFER TO SPECIFlCATION SECTION 22 OS OS FOR ADDITIONAL INFORMATION. MECHANICAL GENERAL NOTES: THESE NOTES APPLV TO ALL M ECHANICAL SHEETS AND TRADES, INC W DING BUT NOT LI MITED TQ FIRE PROTECTION, PLUMBWG, MEDICAL GAS, VENTILATION, PIP WG AND TEMPERATURE CONTROL. 1. DRAWINGSSHOWINGLOCATIONSOFEQUIPMENT,DUCTWORK,PIPING,ETC.ARE DIAGRAMMATIC AND MAV NOT ALWAVS REFLECT EXACT INSTALLATION CONDITIONS. DRAW WGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIP WG, EQUIPM ENT, ETC., AND MAV NOT INC W DE ALL OFFSETS AND FlTTINGS REpUIRED FOR COMPLETE INSTALLATION. THEDRAWWGSSHALLBEFOLLOWEDASCLOSELVASACTUALBUILDWG CONSTRUCTIONAND THE WORK OF OTHERS WILL PERMIT. 2. DONOTSCALEDRAWINGS. VERIFVALLDIMENSIONSANDCLEARANCESFROM ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR PHVSICALLV ATSITE REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES. 3. COORDINATEALLWORKWITHALLOTHERTRADESPRIORTOINSTALLATIONTOPROVIDE CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO VERIFV NON-INTERFERENCE W ITH OTHER WORK. DO NOT FABRICATE PRIOR TO VERIFICATION OF NECESSARV CLEARANCES FORALL TRADES. BRING ANV INTERFERENCES OR CONFLICTS TO THE ATTENTION OF THE ARCMTECT/ENGINEER BEFORE PROCEEDI NG WITH FABRICATION OR EQUIPMENT ORDERS. 4. REVIEW SPACE REpUIREMENTS OF EpUIPMENTSPEQFIED OR SUBSTITUTED AND MAKE RFASONABLE ACCOMMODATIONS IN LAVOUT AND POSITIONING TO PROVIDE PROPER ACCESS. 5. ANVCHANGESRE�UIREDTOELIMINATECONFLICTSORTHATRESULTFROMAFAILURETO COORDINATE SHALL BE MADE BV THE CONTRACTOR WITHOUT ADDITIONAL COST OR EXPENSE TO OTHERS. 6 EACHCONTRACTORISRESPONSIBLEFORALLCOSTSASSOCIATEDWITHELECTRICAL CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF DESIGN. 1. REFERTOARCHITECTURALRERECTEDCEILINGPLAN,ELECTRICAL,TECHNOLOGY AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILI NG MOUNTED DEVICES, OTHER THAN SPRINKLERS. 8. EACHCONTRACTORISRESPONSIBLEFORDAMAGECAUSEDBVTHEIRACTIONSTOWALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS RESPONSIBLE FOR PATCHWG TO MATCH ORIGINAL CONSTRUCTION, FIRE RATWG, AND FlNISH. 9. IN AREAS W ITH DRV WALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS W ITH THE GC FOR ACCESS TO VALVES, DUCTW ORK ACCESSORIES, DAM PERS, ETG COORDINATE PANEL iYPE AND COLOR WITH ARCHITECT. NOTIFV THE GC OF THE RE�UIRED ACCESS PANELS PRIOR TO BIDDING. 10- SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT W HERE CONDUITS, PIP W G, AND DUCTS PENETRATE PENETRATIONS THROUGH EXTERIOR WALLS AND ROOF SHALL BE SEALEDAIRTIGHT WITH WATERPROOFING MATERIALS RECOMMENDED BV MANUFACTURER FOR OUTDOOR USE. 11. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL, PARTITION, FLOOR, AND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE TRANSMISSION FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS WITHIN ROOMS. 12. WHEREPIPESANDDUCTSARESHOWNTOPENETRATEFLOORS,PROVIDESLEEVED OPENINGS WITH THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE WITH ALL RELEVANT SPEC SECTIONS. SEAL SLEEVE PERIMETER TO BE WATERTIGHT. 13 E�UIPMENTSIZESANDSERVICEQEARANCERE�UIREMENTSVARYAMONGDIFFERENT MANUFACTURERS. CONSULT APPROVED SHOP DRAW INGS FOR EQUIPMENT SIZES AND REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAVOUT OF EQUIPMENT PADS, PIPING, DUCTWORK, ETC. 14. DO NOT BLOCK NBE PULL OR EpUIPM ENT SERVICE CLEARANCES. 15. MAINTAIN MINIMUM 3'-6" CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR STARTERS, SWITCHES, AND DISCONNECTS. i6. PROVIDE CONCRETEEQUIPMENTPADFORALLFLOORMOUNTEDEQUIPMENT.PADSHALL EXTEND MINIMUM 6" BEVOND ALL SIDES OF EQUIPMENT. 11. DO NOTSUPPORT WUIPMENT, PIPWG, OR DUCTWORK FROM METAL DECKWG OR OTHER NONSTRUCNRAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS. MECHANICAL RENOVATION NOTES: THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED TO, FIRE PROTECTION, PLUMBING, MEDICALGAS, VENTILATION, PIPING AND TEMPERATURE CONTROL. 1. EXISTING CONDITIONSARE SHOWN BASED ON INFORMATION OBTAWED FROM FIELD SURVEVS, EXISTWG BUILDING DOCUMENTS, AND STAFF. VERIFV EXIST WG CONDITIONS AND REPORT ANV CONFLICTS BEFORE PROCEEDWG. 2. NOTALLEXISTINGDUCiWORKANDPIPINGISSHOWN. VERIFYEXISTINGCONDITIONS BEFORE STARTING WORK. NOTIFV ENGINEER OF ANV CONFLICTS WITH NEW WORK. 3. FIELDVERIFVTHEAVAILABLECLEARANCESFORDUCTWORKANDPIPWGBEFORE FABRICATION. RISESAND DROPS MAV BE NECESSARV BECAUSE OF EXISTING FlELD CONDITIONS. 4. FACHCONTRACTORSHALLFIELDVERIFVACCESSIBILITVTOTHEAREAOFHISIHERWORK AND SHALL NOTIFV THE CONSTRUCTION MANAGER PRIOR TO BIDDING IF OTHER UTILITIES ARE REQUIRED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO HIS/HER AREA OF WORK. S THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, REMOVALAND PATCHING OF ROOFS, WALLS, AND FLOORS ASSOQATED W ITH WORK BV ALL CONTRACTORS. CONTRACTORS SHALL NOTIFV THE GC OF AFFECTED AREAS PRIOR TO BIDD W G. 6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOQATED W ITH AREAS OF WORK BV ALL CONTRACTORS. NOTIFV THE GENER4L CONTRACTOR OF AFFECTED AREAS PRIOR TO BIDDWG. ]. WHEREEXISTINGMECHANICALSVSTEMSARELOCATEDINAREASTHATCONFLICTWITH NEW EQUIPM ENT, PIPING, OR DUCTW ORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER ARRANGE NEW WUIPMENT, PIPWG, OR DUCTWORK IN SUCHA FASHION THAT IT DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING MECHANICAL SVSTEMS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIP W G, OR DUCTW ORK. e. PROVIDE TEMPORARV CONNECTIONS TO MAINTAIN EXISTWG SVSTEMS IN SERVICE DURWG CONSTRUCTION. MAINTAIN ACCE55 TO EXISTING MECHANICAL INSTALLATIONS THAT REMAIN ACTIVE. 9. OBTAIN PERMISSION FROM OW NER BEFORE SHUTTWG DOWN ANV SVSTEM FOR ANV REASON. MAINTAIN SERVICE TO ALL COM PONENTS THAT ARE TO REMAIN UNTIL NEW SVSTEMS ARE INSTALLED. 10. MAINTAIN EXISTWG SVSTEM IN SERVICE UNTIL NEW SVSTEM IS COMPLETE AND READV FOR TIE IN AND SW ITCHOVER. DRAIN SVSTEM ONLV TO MAKE SW ITCHOVERS AND CONNECTIONS. OBTAIN PERMISSION FROM OWNER BEFORE PARTIALLV OR COMPLETELV DRAINWG SVSTEM. MAKE CHANGEOVER TO NEW SVSTEMS WITH MINIMUM OUTAGE. 11. DISCONNECTAND REMOVE MECHANICAL DEVICESAND E�UIPMENTSERVING E�UIPMENT THAT HAS BEEN REMOVED. �:I M EG r'oaec�PomF o�z�m =m' o im�maP a�av�sPaaPaiEruzr ai�rs wcwowewwei�wrsra rHis rHE Exc�usi�E PROPERry oF iMEc coRP n�No sHau rvor eE usEo oR�AARE eE>a�oucmroreiwromEara� c�xurmEExraEssviainEry p 0 m 9 a aQ 'm E u o` a� N � o C U ai °J 3 a' `� R � o � ���d� x � 03= a 's " _ § = -= os=�<�` - o `- -_' o�� _ _ >. _ _- mo%Eoso o� ���o�s.,a�_a Oa � NJ. ., � � r * E112GGo55 �_ s`� ` � � ��� S/C�� L�C�� �[/ I 3/ I 9 wnmumninxnoo� REVISIONS J W � � a U i F Q W 2 Z Q U � U � � Z LL �C.�..� R C � w a F U Z cn � W 0 WN Z W I.L J � O W _ �a�a'v J a Z ? U W y m � Q�oo� W U LL � � 0 � r= o �� � uJ = m md= � a_ � Q _ q s �-=2 `N � ` � U = L _ � : � c � w � R m� il Q PLUMBING COVERSHEET P0.00