Loading...
HomeMy WebLinkAboutInstallation SpecsSystem Weight Total system weight 1,627.6 lbs Weight/attachment 37.0 lbs Racking weight 281.5 lbs Distributed weight 2.7 psf Load Assumptions Wind exposure B Wind speed 115 mph Ground snow load 20 psf Attachment spacing 6.0' Span Details XR100 - Portrait Zone Max span Max cantilever 1 6' 11" 2' 9" 2 6' 11" 2' 9" 3 6' 11" 2' 9" Reaction Forces XR100 - Portrait Zone Down (lbs) Uplift (lbs) Lateral (lbs) 1 252 167 105 2 252 205 105 3 252 205 105 Project Details Name Nathan Titus Date 12/06/2019 Location 239 Ironwood Drive West, Carmel, IN, 46033 Total modules 33 Module Panasonic: VBHN340SA17 (40mm) Total watts 11,220 Dimensions 62.6" x 41.46" x 1.57" (1590.0mm x 1053.0mm x 40.0mm) Attachments 44 Roof Information Roof material Comp Shingle Building height 25 ft Roof attachment Flashfoot2 Roof slope 35 ° Attachment hardware Square Risk category II Last updated by Joel Walsman on 12/06/19 09:52 AM Page 1 of 6 Nathan Titus (#578874) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti Roof Section 1 Definition Roof Section Weights Roof Section (all segments) 21 modules Total weight: 1,030.0 lbs Provided rail: 174' [10 x 14', 2 x 17'] Portrait orientation Weight/attachment: 36.8 lbs Attachments: 28 Graphical entry Total Area: 384.0 sq ft Splices: 6 Distributed weight: 2.7 psf Clamps: 48 Diagram 38' 4"10' 6"Cantilever Violations Segments Columns Length Cantilever Rail Attachments Splices Clamps 4 14' 1" 1' None 34' [2 x 17'] 6 0 10 6 21' 1" 1' 6" None 56' [4 x 14'] 8 2 14 11 38' 6" 1' 3" None 84' [6 x 14'] 14 4 24 Roof Section 2 Definition Roof Section Weights Roof Section (all segments) 12 modules Total weight: 598.1 lbs Provided rail: 112' [8 x 14'] Portrait orientation Weight/attachment: 37.4 lbs Attachments: 16 Graphical entry Total Area: 220.3 sq ft Splices: 4 Distributed weight: 2.7 psf Clamps: 28 Diagram 20' 11" 10' 6"Cantilever Violations Segments Columns Length Cantilever Rail Attachments Splices Clamps 6 21' 1" 1' 6" None 56' [4 x 14'] 8 2 14 Row segment totals (x 2) → 112' [8 x 14'] 16 4 28 Last updated by Joel Walsman on 12/06/19 09:52 AM Page 2 of 6 Nathan Titus (#578874) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti Side View (portrait) 35° BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Front View (portrait) ATTACHMENT SPAN 6.0’ BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Last updated by Joel Walsman on 12/06/19 09:52 AM Page 3 of 6 Nathan Titus (#578874) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti Splice Details XR100 SIDE-FACING SLOT INTERNAL SPLICE TOP-FACING SLOT Splice Connection INTERNAL SPLICE RAIL SELF-DRIVING SCREW Clamp Detail Mid Clamp, Plan UNIVERSAL FASTENING OBJECT PV MODULE FRAME Mid Clamp, Front RAIL PV MODULE FRAME UNIVERSAL FASTENING OBJECT End Clamp, Plan STOPPER SLEEVE UNIVERSAL FASTENING OBJECT PV MODULE FRAME RAIL 1” End Clamp, Front PV MODULE FRAME RAIL UNIVERSAL FASTENING OBJECT STOPPER SLEEVE1” FlashFoot2 Detail Plan View 9” 12” 2 “3 16 Side View 1 “11 16 Perspective View Front View 1 “5 8 3 “5 16 “5 16 Last updated by Joel Walsman on 12/06/19 09:52 AM Page 4 of 6 Nathan Titus (#578874) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti Grounding Diagram * Grounding Lugs and Wire are not required in systems using Enphase microinverters. UFO Clamp Fault Current Ground Path Min 10 AWG Copper Wire * Grounding Lug * Bonded Splice (Rail Connection) Last updated by Joel Walsman on 12/06/19 09:52 AM Page 5 of 6 Nathan Titus (#578874) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti Bill of Materials Part Spares Total Qty Rails & Splices XR-100-204B XR100, Rail 204" (17 Feet) Black 0 2 XR-100-168B XR100, Rail 168" (14 Feet) Black 0 18 XR-100-SPLC-M1 XR100 Bonded Splice (Incl. Self-tapping Screws) 0 10 Clamps & Grounding UFO-CL-01-B1 Universal Module Clamp, Black 0 76 UFO-STP-40MM-B1 Stopper Sleeve, 40MM, Black 0 20 XR-LUG-03-A1 Grounding Lug, Low Profile 0 5 Attachments FF2-01-B1 FlashFoot2, Black 0 44 BHW-SQ-02-A1 Square-Bolt Bonding Hardware 0 44 Accessories 29-4000-077 Wire Clips, Molded PVC Black, Polybag 20 0 4 XR-100-CAP Kit, End Cap XR100 (10 sets per bag) 0 1 BHW-MI-01-A1 Microinverter Bonding Hardware, T-Bolt 0 33 Last updated by Joel Walsman on 12/06/19 09:52 AM Page 6 of 6 Nathan Titus (#578874) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti