Loading...
HomeMy WebLinkAboutInstallation SpecificationsSystem Weight Total system weight 1,066.7 lbs Weight/attachment 38.1 lbs Racking weight 169.3 lbs Distributed weight 2.6 psf Load Assumptions Wind exposure B Wind speed 115 mph Ground snow load 20 psf Attachment spacing 6.0' Span Details XR100 - Portrait Zone Max span Max cantilever 1 6' 9" 2' 8" 2 6' 9" 2' 8" 3 6' 9" 2' 8" Reaction Forces XR100 - Portrait Zone Down (lbs) Uplift (lbs) Lateral (lbs) 1 277 166 106 2 277 204 106 3 277 204 106 Project Details Name 13334 Roma Bend Date 12/17/2019 Location Westfield, IN, 46074 Total modules 22 Module Panasonic: VBHN340SA17 (40mm) Total watts 7,480 Dimensions 62.6" x 41.46" x 1.57" (1590.0mm x 1053.0mm x 40.0mm) Attachments 28 Roof Information Roof material Comp Shingle Building height 30 ft Roof attachment Flashfoot2 Roof slope 30 ° Attachment hardware Square Risk category II Last updated by Joel Walsman on 12/17/19 10:03 AM Page 1 of 6 13334 Roma Bend (#577857) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti Roof Section 1 Definition Roof Section Weights Roof Section (all segments) 22 modules Total weight: 1,066.7 lbs Provided rail: 168' [12 x 14'] Portrait orientation Weight/attachment: 38.1 lbs Attachments: 28 Graphical entry Total Area: 402.7 sq ft Splices: 8 Distributed weight: 2.6 psf Clamps: 48 Diagram 38' 4"10' 6"Cantilever Violations Segments Columns Length Cantilever Rail Attachments Splices Clamps 11 38' 6" 1' 3" None 84' [6 x 14'] 14 4 24 Row segment totals (x 2) → 168' [12 x 14'] 28 8 48 Side View (portrait) 30° BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Last updated by Joel Walsman on 12/17/19 10:03 AM Page 2 of 6 13334 Roma Bend (#577857) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti Front View (portrait) ATTACHMENT SPAN 6.0’ BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Splice Details XR100 SIDE-FACING SLOT INTERNAL SPLICE TOP-FACING SLOT Splice Connection INTERNAL SPLICE RAIL SELF-DRIVING SCREW Last updated by Joel Walsman on 12/17/19 10:03 AM Page 3 of 6 13334 Roma Bend (#577857) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti Clamp Detail Mid Clamp, Plan UNIVERSAL FASTENING OBJECT PV MODULE FRAME Mid Clamp, Front RAIL PV MODULE FRAME UNIVERSAL FASTENING OBJECT End Clamp, Plan STOPPER SLEEVE UNIVERSAL FASTENING OBJECT PV MODULE FRAME RAIL 1” End Clamp, Front PV MODULE FRAME RAIL UNIVERSAL FASTENING OBJECT STOPPER SLEEVE1” FlashFoot2 Detail Plan View 9” 12” 2 “3 16 Side View 1 “11 16 Perspective View Front View 1 “5 8 3 “5 16 “5 16 Last updated by Joel Walsman on 12/17/19 10:03 AM Page 4 of 6 13334 Roma Bend (#577857) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti Grounding Diagram * Grounding Lugs and Wire are not required in systems using Enphase microinverters. UFO Clamp Fault Current Ground Path Min 10 AWG Copper Wire * Grounding Lug * Bonded Splice (Rail Connection) Last updated by Joel Walsman on 12/17/19 10:03 AM Page 5 of 6 13334 Roma Bend (#577857) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti Bill of Materials Part Spares Total Qty Rails & Splices XR-100-168B XR100, Rail 168" (14 Feet) Black 0 12 XR-100-SPLC-M1 XR100 Bonded Splice (Incl. Self-tapping Screws) 0 8 Clamps & Grounding UFO-CL-01-B1 Universal Module Clamp, Black 0 48 UFO-STP-40MM-B1 Stopper Sleeve, 40MM, Black 0 8 XR-LUG-03-A1 Grounding Lug, Low Profile 0 2 Attachments FF2-01-B1 FlashFoot2, Black 0 28 BHW-SQ-02-A1 Square-Bolt Bonding Hardware 0 28 Accessories 29-4000-077 Wire Clips, Molded PVC Black, Polybag 20 0 3 XR-100-CAP Kit, End Cap XR100 (10 sets per bag) 0 1 BHW-MI-01-A1 Microinverter Bonding Hardware, T-Bolt 0 22 Last updated by Joel Walsman on 12/17/19 10:03 AM Page 6 of 6 13334 Roma Bend (#577857) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 01/14/20 David Rutti