Loading...
HomeMy WebLinkAboutGN010.0 LEGACY AMENITY AREA SHELTER1 - Cover SheetGENERAL REQUIREMENTS AND GUIDELINES FOR THIS PROJECT: THE CONTRACT DOCUMENTS CONSIST OF THE DRAWINGS AND SPECIFICATIONS ON THE DRAWINGS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ITEMS NECESSARV FOR THE PROPER EXECUTION OF THE WORK. THE CONTROLLING CODE FOR ALL WORK UNDER THESE DRAWINGS SHALL BE THE INTERNATIONAL BUILDING CODE 2014 WITH INDIANA AMENDMEMS, ALL IN THEIR CURRENT ADDITIONS. indiana Adopted Codes for Building Construction In effect December 1, 2014 2014Indiana Buildine Code Adop[ion by Reftrence: 2012In[ecna[ional Ruilding Code First Printing plus indiana Amendments, eti�ective December 1st2014. 20091ndiana Llectrical Code Adoption by Refecence: 2008 National THE CONTROLLING DOCUMEM FOR ALL WORK UNDER THESE DRAWINGS Elechic Code FirstPrin[in� plus Indiana Amendmen[s, effec[ive Au�ust 26, SHALL BE THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, 2009. AIA (AMERICAN INSTITUTE OF ARCHITECTS) DOCUMENT A201, CURRENT EDITION. AGREEMENT BV ANV PARTV TO WORK UNDER THIS CONTROLLING DOCUMENT SHALL COMMENCE WITH THE START OF ANV WORK DESCRIBED 2014 Indiana Fucl Gas Codc Adop[ion by Rcfcrcncc: 2012In[crna[ional WITHIN THESE DOCUMENTS Fuel Code Fics[ Pcin[ingplus Indiana Amendmen[s, effec[ive Decembec Is[ 3014. THE ARCHITECT SHALL FILE FOR STATE PLAN REVIEW AND PROVIDE A RELEASE FOR USE IN OBTAINING LOCAL PERMITS. THE GENERAL CONTRACTOR SHALL 2014 Indiana Mechanical Code Adoption by Reference: 20127ntemational FILE DRAWINGS OR OTHER MATERIALS FOR PERMIT APPLICATION AT THE Mcchanical Codc First Printing plus Indiana Micndmcnts, cffcctivc LOCAL LEVEL AND SECURE ALL NECESSARV BUILDWG PERMITS. SUB- CONTRACTORS TO THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR Uecember I st 2014. OBTAINING THEIR OWN LOCAL PERMITS. PRIOR TO COMMENCWG ACTNITIES, FACH CONTRACTOR AND MATERIAL SUPPLIER SHALL CAREFULLV STUDV AND COMPARE THE CONTRACT DOCUMENTS AND BECOME FULLV AWARE OF THE REQUIREMENTS. EACH CONTRACTOR AND MATERIAL SUPPLIER SHALL TAKE FIELD MEASUREMENTS AND VERIFV FIELD CONDITIONS AND SHALL CAREFULLV COMPARE SUCH MEASUREMENTS AND CONDITIONS WITH THE CONTRACT DOCUMENTS. 2012 Indiana Plumbin¢ Code Adoption by Reference: 2006 International Plumbing Cnde Second Printing plus the Indiana Amendments, effective Decembec 24, 2012. 2005 Iodiaoa Resideotial Code Adoptioo by Refeceoce: 2003 Iotematiooal Residential Code FiRh Printing plus Indiana Amendments, effective Scptcmbcc I I, 2005. IN THE EVENT OF INCONSISTENCIES WITHIN OR BETWEEN THE CONTR4CT DOCUMEMS, EACH COMR4CTOR OR MATERIAL SUPPLIER SHALL PROVIDE THE ?014 Indiana Fire Code Adop[ion by Reftcence: 2012In[ecna[ional Fice BETTER QUALITV OR GREATER QUAMITV OF THE WORK, AND SHALL COMPLV Code First Printing plus Indiana Amendments, eti�ective December 1 st 2014. WITH THE STRICTER REQUIREMENT. INCONSISTENCIES DISCOVERED SHALL BE IMMEDIATELV REPORTED TO THE ARCHITECT IN WRITING. NO PLEAS OF IGNORANCE RESULTING FROM FAILURE TO EXAMWE THE REQUIREMENTS OF THE CONTRACT DOCUMENTS OR THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED WILL BE ACCEPTED AS AN EXCUSE FOR FAILURE OR OMISSION ON THE PART OF EACH CONTRACTOR AND MATERIAL SUPPLIER TO FULFILL IN EVERV RESPECT ALL REQUIREMENTS OF THECONTRACTDOCUMENTS. VERIFV THAT SURFACES TO RECEIVE MATERIALS ARE IN A CONDITION TO ACCOMMODATE INSTALLATION. IMMEDIATELV REPORT TO THE ARCHITECT ANV DISCREPANCIES OR ERRORS WHICH WOULD RESULT IN POOR APPLICATION OR CAUSE LATENT DEFECTS IN WORKMANSHIP. IF A CONTRACTOR OR SUB- CONTRACTOR PROCEEDS WITH INSTALLATION OF MATERIALS OVER ANOTHER CONTRACTOR'S WORK, IT SHALL BE ASSUMED THAT THE CONTRACTOR OR SUB- CONTRACTOR ACCEPTS THE WORK TO RECEIVE HIS MATERIAL. ALL LABOR, CONSTRUCTION MATERIALS, PROVIDED AND INSTALLED TO COMPLETE THE WORK OF THESE CONTRACT DOCUMENTS SHALL BE EXECUTED IN COMPLETE COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES, PRACTICES OR ORDINANCES AND WITHIN THE CONSTRAINTS OF THE HIGHEST ACCEPTABLE CONSTRUCTION PRACTICES. UPON COMPLETION OF THE PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BV THE LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCV, IF ISSUED BV THE JURISDICTION. THE GENERAL CONTR4CTOR SHALL PROVIDE REASONABLE SUPERVISION AND COORDINATION OF ALL SUB-CONTRACTORS WORK INCLUDING WORK PERFORMED BV OTHERS SUCH AS SUPPLIERS OF OWNER-SUPPLIED ITEMS. UPON COMPLETION OF PROJECT, PROVIDE OWNER WITH ALL INSTRUCTION MANUALS, WARRANTIES OR OTHER DOCUMENTS REQUIRED FOR THE PROPER OPERATION OR MAINTENANCE OF ANV PART OF THE CONTRACTOR'S WORK. THE GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARV PROTECTION AND SECURITV MEANS FOR HIS WORK UNTIL TURNED OVER TO THE OWNER. IF THE PROJECT AREA IS TO BE USED BV EMPLOVEES OR THE PUBLIC DURING CONSTRUCTION, FULLV PROTECT THE CONSTRUCTION SITE, CONSTRUCT BARRIERS AND FENCING, AND PROVIDE APPROPRIATE SIGNAGE TO PROTECT THESEPERSONS. THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN MINIMUM GENERAL LIABILITV INSURANCE. THE FRANCHISEE, FRANCHISER, AND THE ARCHITECTS SHALL BE HELD HARMLESS AGAINST ALL GENERAL LIABILITV CLAIMS THAT MAV RESULT AS A PART OF THIS PROJECT. IF THE GENERAL COMR4CTOR DISCOVERS WNDITIONS THAT ARE NOT SUBSTANTIALLV LIKE THE ARCHITECTS DRAW INGS, THE ARCHITECT OR ENGINEER SHALL BE IMMEDIATELV NOTIFIED. THIS NOTIFICATION RELATES TO ALL PARTS OF THIS PROJECT, INCLUDING BUT NOT LIMITED TO DISCOVERED SOIL CONDITIONS, INAPPROPRIATE OR NON- SPEGFIED PRODUCTS DELNERED AND/OR INSTALLED ON SITE, OR ANV QUESTION REGARDING POSSIBLE VIOLATION OF CODES OR ORDINANCE STANDARDS. PROCEEDWG WITH THE WORK SHALL CONSTITUTE ACCEPTANCE BV THE GENERAL CONTRACTOR OF THE EXISTING CONDITIONS, AND THAT THE PROJECT CAN BE BUILT STRUCTURALLV SOUND AND MEETING LOCAL CODES. 2010Indiana Enerev Conservation Code Adoption by Reference: 2007 Edi[ion ASHRAE 90.1 plus Indiana Amendmen[s, effec[ive May 6, 2010. A Complece list ofell coAes enA other mles eAopceA by the Fire Prevention & RuilAinb Safcry Commission of Hic Statc of Indiana along wiHi PDF vcrsions of Hiclndiana Amendments can be found at hanYh.e�.e�v iii ¢oe/Ahs249(1 hmi SHELTER STRUCTURE FOR: TH E LEGACY AM EN ITY AREA HAMILTON COUNTY, INDIANA INDEX OF DRAWINGS OF THIS SET: ARCHITECTURAL DRAWINGS: COVER SHEET; GENERAL PROJECT GUIDELINES; SHEET INDEX A R C H T E C T u �" Na, � ''F o AR0003253� o SiRiE OF 1.1 OVERALL SITE PLAN; FENCE AND GATE DETAILS � GORDON CLARK ARCHITECT AIA 4820 Buttonwood Crescent � Indianapolis, Indiana 46228 ■ Phone: 317 255-2546 � Fax: 317 252-5573 ■ GCIark4820@aol.com ■ A1.1 FLOOR PLANS; TRANSVERSE SECTION; FOUNDATION DETAIL; POST DETAIL A2.1 BUILDING ELEVATIONS; ELECTRICAL PLAN; PARTIAL POOL HOUSE PLAN SHOWING PANEL LOCATION; ELECTRICAL SPECIFICATIONS; RISER DIAGRAM A3.1 MISCELLANEOUS SPECIFICATIONS m M.. _ � RELEASED FOR CONSTRl1CTI0N DATE: O� �ZZ�ZO Su6jec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `�j sv�� �\o�v�AW.� � DRAWING COMPLETION DATE: JANUARY 9, 2020