HomeMy WebLinkAboutA010.0 LEGACY AMENITY AREA SHELTER4 - A2.1ELECTRICAL SPECIFICATIONS AND GENERAL REQUIREMENTS: THE CONTRACT DOCUMENTS CONSIST OF THE DRAWINGS AND SPECIFICATIONS ON THE DRAWINGS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ITEMS NECESSARY FOR THE PROPER EXECUTION OFTHE WORK. BUILDING CODES: NEW CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CITY, STATEAND LOCAL BUILDING CODES FORTHIS CLASS OF WORK. ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS AT THE JOBSITE. IF DISCREPANCIES ARE FOUND THE GENERAL CONTRACTOR SHALL BE NOTIFIES BEFORE PROCEEDING WITH ANY WORK OR ORDERING ANY EQUIPMENT OR MATERIAL IN THE AFFECTED AREA. FIT AND QUANTITY OF THE WIRING, ELECTRICAL EQUIPMENT, THE VARIOUS NECESSARY PARTS AND MATERIALS TO MAKE A COMPLETE AND FINISHED JOB SHALL BE VERIFIED AND COORDINATED PRIOR TO START OF CONSTRUCTION AND ARE THE EXCLUSIVE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. LOCAL UTILITY COORDINATION: ELECTRICAL CONTRACTOR SHALL COORDINATE TRANSFORMERS AND SERVICE REQUIREMENTS WITH THE LOCAL UTILITY COMPANY. THE EC. SHALL CONSULT WITH THE LOCAL UTILITY TO ESTABLISH REQUIRED kACI RATINGS. ALL FIXTURES, EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S SUGGESTED INSTALLATION REQUIREMENTS IN A NEAT AND WORKMANLIKE MANNER. UL LABELING: ALL ELECTRICAL EQUIPMENT SHALL HAVE "UL" LABELS. WIRING DEVICES SHALL BE SPECIFICATION GRADE. PROVIDE ALL DISCONNECTS REQUIRED PER NATIONAL AND LOCAL ELECTRICAL CODES RATED TO UTILITY SUPPLIED kAIC LIMITS, OR, IF NOT SUPPLIED, TO NEC MINIMUMS. ALL EXPOSED WIRE AND WIRING BELOW CONCRETE SLABS SHALL BE IN CONDUIT. WIRE: ALL WIRE SHALL BE COPPER, MINIMUM SIZE #12 AWG. ALL CONDUCTORS SHALL HAVE TYPE "THHN" INSULATION. CONDUCTORS #10 AND SMALLER MAY BE SOLID. GROUNDING CABLES SHALL BE NO SMALLER THAN 4 COPPER. BREAKER PANELS: FURNISH AND INSTALL A BREAKER PANEL AS MANUFACTURED BY SQUARE D OR ITE. INSTALL PANEL SO TOP BREAKER IS NO HIGHER THAN 6'-0". FURNISH AND INSTALL TYPEWRITTEN DIRECTORY. IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. GROUNDING: GROUNDING SHALL BE DONE STRICTLY ACCORDING TO SECTION 250.52 OF THE NATIONAL ELECTRIC CODE USING ACCEPTABLE ELECTRODES AND CONNECTIONS. SWITCHES: ALL SWITCHES SHALL BE RATED 20 AMP, 125 VOLT AND SHALL BE MOUNTED 4'-6" AFF, UNLESS NOTED OTHERWISE. RECEPTICALS: ALL RECEPTA0.ES TO BE 15 AMP, 125 VOLT, GROUNDING TYPE AND SHALL BE MOUNTED 18" AFF, UNLESS NOTED OTHERWISE. PROVIDE TEMPORARY POWER REQUIRED BY THE GENERAL CONTRACTOR AND OTHER TRADES. COORDINATE POWER REQUIREMENTS WITH GC PRIOR TO INSTALLATION. LIGHTING FIXTURES: LIGHTING FIXTURES TO BE FURNISHED AND INSTALLED COMPLETE WITH LAMPS AS DETAILED ON THE PLANS OR AS INTENDED. SEE REFLECTED CEILING PLAN ANDIOR LIGHTING PLAN FOR THE EXACT LOCATION OF THE CEILING GRID, LIGHT FIXTURES, OR THE GENERAL INTENT OF THE DRAWINGS. SEE THE ELECTRICAL DRAWING(S) FOR THE FIXTURE SCHEDULE, NOTES AND OTHER SPECIFICATION REQUIREMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR NOTICE TO THE INSPECTING AUTHORITIES, ARCHITECT, OR GENERAL CONTRACTOR, SO THAT WORK CAN BE INSPECTED OR APPROVED BEFORE COVERING. THIS PROCEDURE SHALL OCCUR WITHOUT AFFECTING CONSTRUCTION PROGRESS AND COMPLETION. THE INTENTION OF THESE DOCUMENTS IS TO PROVIDE THE OWNER WITH A BUILDING COMPLETE IN ITS ENTIRETY AT THE TIME OF OCCUPANCY. IT IS THE SUB-CONTRACTOR'S RESPONSIBILITY TO CONTACT THE GENERAL CONTRACTOR DURING THE BIDDING/PRICING PHASE OF ANY DETAILS MISSING, RELEASED FOR CONSTRl1CTI0N ETE SO THAT AN APPROPRIATE ADDENDUM OR 3E ISSUED. THE SELECTED CONTRACTOR SHALL PROVIDE Su6jec��ocompliancewithallregula�ions �R, TOOLS, EQUIPMENT, AND SERVICES NECESSARY FOR A o4S�a�eantlLocalCodes NAL,ANDOPERATIONALFACILITY. City of Carmel `�j sv�� �\'��v�AWnT � TOO 100 AMP PANEL IN POOLHOUSE I I I ,�� I I I / / P LED CAN LIGHTS IN � WOOD SOFFIT / (TVPICAL FOURJ (/ --� CEILING CONVEIyIENCE �JTLET � I WOOD SOFFIT CEILING � ; — \ °'�_______________ b CONDUIT FEED FROM POOL HOUSE AS REQUIRED ELECTRICAL AND LIGHTING PLAN SCHLE 1/S" - 1'-O" PARTIAL POOL HOUSE PLAN SHOWING ELECTRICAL PANEL G(:A1 F 'I /R•• ='I•-0•• 10 AMP ISFORM R gREAKERS AS =QUIRE REQUIRED— rwo a vz• coNowTs = W/4-500 MCM - IF REQUIRE� [H�� PERGOLA 6 FOOT HIGH POOL FENCE RISER DIAGRAM NOT TO SCALE GROUND PER NEC ELECTRICAL SYSTEM GROUNDING REQUIREMENTS: STRICTLY FOLLOW NEC 250.50 AND 250.52. YCII�[H�� PERGOLA 6 FOOT HIGH POOL FENCE INSTALL GROUNDING ELECTRODE ACCORDING TO THE FOLLOWING LIST: WATER PIPE IF 10 FEET OR MORE OF METAL WATER PIPE IS IN CONTACT WITH THE EARTH. METAL FRAME OF THE BUILDING OR STRUCTURE WHERE ANY OF THE FOLLOWING FOUR METHODS ARE USED TO MAKE AN EARTH CONNECTION: 1. CONCRETE-ENCASED ELECTRODE IN AT LEAST 2 INCHES OF CONCRETE LOCATED WITHIN OR NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR FOOTING THAT IS IN INDIRECT CONTACT WITH THE EARTH. 2. GOUND RING ENCIRCLING THE BUILDING OR STRUCTURE IN DIRECT CONTACT WITH THE EARTH. 3. ROD OR PIPE ELECTRODE NOT LESS THAN 8 FEET IN LENGTH. 4. OTHER LOCAL UNDERGROUND SYSTEMS SUCH AS PIPING, UNDERGROUND TANKS AND UNDERGROUND WELL CASING. COMMUNICATIONS EQUIPMENT: COMMUNICATIONS EQUIPMENT SHALL BE GROUNDED TO BUILDING GROUNDING ELECTRODE SIMILAR TO OTHER ELECTRICAL EQUIPMENT. FOLLOW NEC 800.100 (B). ALL GROUNDING ELECTRODES THAT ARE PRESENT AT THIS BUILDING STRUCTURE SHALL BE BONDED TOGETHER TO FORM THE GROUNDING ELECTRODE SYSTEMS. BOND ALL GROUNDING ELECTRODES THAT ARE PRESENT AT THIS BUILDING STRUCTURE TOGETHER TO FORM THE GROUNDING ELECTRODE SYSTEM. GROUNDING ELECTRODES THAT MAY BE PRESENT AT THIS BUILDING INCLUDE GROUNDING ELECTRODE RODS, CONCRETE ENCASED ELECTRODES SUCH AS BUILDING FOUNDATION REBAR, UNDERGROUND METAL WATER PIPES, AND METAL FRAME OF THE BUILDING INCLUDING STRUCTURAL STEEL COLUMNS. SEE GROUNDING DETAIL THAT IS A PART OF DRAWINGS OF THIS SET NOT PERMITTED: METAL UNDERGROUND GAS PIPING. ALUMINUM ELECTRODES Q Q F U W F 2 U � Q Y � Q J U Z � O � � � ■ W � � � U � � � � � W � J w _ � ����� � N N N � yt0 N N_ � a N N 0 U � N N � � � � r W 3 � M M � C i' � N � K � m ms�C7 o�a N � W � V C � L.I_ � � � Z WC G Q � U r�n V W J W I � a Z Q � Z } � z � � U Z � H J � Q _ JANUARY 10, 2020 ��ninnun. �o� EDVARp ci.�. ��p9 �G\STEqF �v,p : = u � No. � 'F' = e AR00032537 e STATE OF �1'D I PNP �, ; �� ��,,,. S ELTER A2.1 DATE: O1 �ZZ�2O """ SOUTH ELEVATION SCALE 1/8" = 1'-O" NORTH ELEVATION SCALE 1/8" = 1'-O" EAST ELEVATION $CnLE: 1/8" - 1'-O" WEST ELEVATION $CnLE: 1/8" - 1'-O"