HomeMy WebLinkAboutC200 SITE PLANWEST CA
R
M
E
L
D
R
I
V
E
S00°05'46"E(M) S00°45'10"W(D) 411.64'N00°05'46"W(M) N00°45'10"E(D) 398.63'S89°17'51"W(M) N89°51'24"W(D) 226.23'
N00°50'56"W(M)
N89°26'06"E(M) S89°42'58"E(D) 189.95'S00°50'56"E(M)S00°00'00"E (D)181.33'(M) 182.73'(D)N89°48'49"E(M) S89°20'15"E(D) 190.00'N89°25'05"E(M) S89°43'58"E(D) 241.02'
S89°17'51"W(M)
N89°51'24"W(D)
299.23'
DELTA=10°06'20"
R=561.07'
T=49.61'
L=98.96'
CH BRG=N83°08'42"W(M)
CH LEN=98.83'
PROPOSED BUILDING
20,121SF± PER FLOOR
F.F.E. = 828.60
S2
S1
S3
H3
S2
H3
A1 B1
H1 P1
P3
H3
B2
H5H4
P2
P1
P3
H3
H3
H3
P3
P3
P3
P3
C200SITE PLANW190582-C200 siteSITE PLAN GENERAL NOTES
1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING, OR
VERIFYING THAT ALL PERMITS AND APPROVALS ARE OBTAINED FROM
THE RESPECTIVE CITY, COUNTY, AND STATE AGENCIES PRIOR TO
STARTING CONSTRUCTION.
2.ALL QUANTITIES GIVEN ON THESE PRINTS, VERBALLY OR IN THE
SCOPE OF WORK SECTION ARE ESTIMATES AND SHALL BE CONFIRMED
BY THE BIDDING CONTRACTORS.
3.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA)
STANDARDS FOR EXCAVATIONS; FINAL RULE 29 CFR PART 1926,
SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET
IN DEPTH. IN ADDITION, EXCAVATION EXCEEDING TWENTY (20) FEET IN
DEPTH REQUIRE THE DESIGN OF A TRENCH SAFETY SYSTEM BY A
REGISTERED PROFESSIONAL ENGINEER.
4.IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER AND
CONTRACTOR TO MAINTAIN QUALITY CONTROL THROUGHOUT THIS
PROJECT.
5.TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO
CONFORM TO APPLICABLE LOCAL STANDARDS.
6.BEARINGS, DIMENSIONS, AND EASEMENTS ARE SHOWN FOR
REFERENCE ONLY. SEE RECORD SURVEYS AND PLATS FOR EXACT
INFORMATION.
7.THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE
CONSTRUCTION MEANS AND METHODS ASSOCIATED WITH THE
PROJECT.
8.ALL DIMENSIONS ARE BASED ON FACE OF CURB OR BACK OF ROLL
CURB OR FACE OF BUILDING.
9.SEE ARCHITECTURAL PLANS FOR DETAILS OF BUILDING, BUILDING
DIMENSIONS AND SIGNAGE SPECIFICATIONS. DO NOT STAKE BUILDING
FROM THESE PLANS.
10.COORDINATE CONSTRUCTION ACTIVITIES WITH ADJOINING WORK IF
APPLICABLE. VERIFY EXTENT OF ADJOINING WORK AND COORDINATE
AS REQUIRED.
11.FIELD VERIFY EXISTING CURBS AND TAPER PROPOSED VERTICAL
CURBS TO MATCH WITHIN A MIN. OF THREE (3) FEET.
12.± DIMENSIONS INDICATE FIELD DIMENSION ADJUSTMENT AREA BASED
ON ACTUAL FIELD LAYOUT COORDINATES.
13.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD PRIOR
TO START OF CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR ALL FIELD DIMENSIONS. IF ANY DISCREPANCIES
ARE FOUND IN THESE PLANS FROM ACTUAL FIELD CONDITIONS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY.
14.PROVIDE SMOOTH TRANSITION FROM NEWLY PAVED AREAS TO
EXISTING AREAS AS NECESSARY. ALL AREAS WHERE PROPOSED
PAVEMENT MEETS EXISTING PAVEMENT, THE EXISTING EDGE OF
PAVEMENT SHALL BE FREE OF ALL LOOSE DEBRIS. THE EDGE OF
EXISTING ASPHALT PAVEMENT SHALL BE PROPERLY SEALED WITH A
TACK COAT MATERIAL IN ALL AREAS WHERE NEW ASPHALT PAVEMENT
IS INDICATED TO JOIN EXISTING.
15.RESURFACE OR RECONSTRUCT AT LEAST TO ORIGINAL CONDITIONS
ALL AREAS WHERE THE EXISTING PAVEMENT OR LAWNS ARE
DAMAGED DURING CONSTRUCTION FROM TRAFFIC BY CONTRACTORS,
SUBCONTRACTORS, OR SUPPLIERS AFTER CONSTRUCTION WORK IS
COMPLETE.
16.THE CONTRACTOR SHALL PROTECT AND NOT DESTROY THE
PROPERTY CORNER MONUMENTS DURING CONSTRUCTION.
17.REFER TO ARCHITECTURAL PLANS FOR BUILDING ACCESSORY
DETAILS.
18.REFER TO SHEET C201 FOR SITE PLAN DETAILS UNLESS OTHERWISE
NOTED.
SITE DATA
SITE AREA = 4.37± AC
BUILDING AREA = 20,121± SF PER FLOOR
PERCENT IMPERVIOUS = 87%
ZONING = I-1
FRONT YARD BSL REQUIRED = 0' FT MIN.
10' MAX.
REAR YARD BSL REQUIRED = 0' FT
SIDE YARD BSL REQUIRED = 0' FT
PARKING REQUIRED:
PARKING REQUIREMENT: 1 PER
EMPLOYEE
PARKING DIMENSIONS = 9' x 18'
BIKE PARKING REQUIRED = 4 SPACES
PARKING PROVIDED:
9 - STANDARD SPACES
1 - ADA SPACES
10 - TOTAL SPACES
SITE PLAN NOTES
PAVEMENT
STANDARD DUTY ASPHALT PAVING
STANDARD DUTY CONCRETE
MATCH EXISTING PAVEMENT
HARDSCAPE
INTEGRAL WALK AND CURB
CONCRETE PARKING BARRIER
CONCRETE SIDEWALK
ACCESSIBLE RAMP
PAVEMENT FLUSH WITH SIDEWALK
BUILDING ACCESSORIES
DUMPSTER ENCLOSURE (INSIDE THE BUILDING)
CANOPY
ACCESSORIES
CONNECT EXISTING FENCE TO BUILDING
SIGNAGE & MARKINGS
ACCESSIBLE PARKING SPACE & SIGN ON BUILDING
4" PAINTED WHITE SOLID LINES (TYP)
4" PAINTED WHITE SOLID LINE ISLAND
H1
H2
H3
H4
H5
B1
B2
A1
S1
S2
S3
P1
P2
P3
ELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BUILDING SETBACK LINE
BOUNDARY LINE
CISTERN
DRINKING FOUNTAIN
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
CHILLED WATER MANHOLE
WATER MANHOLE
SPRINKLER CONTROL BOX
SPRINKLER CONTROL VALVE
SPRINKLER
SPIGOT
WELL HEAD
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
FLAG POLE
PARKING METER
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
SEPTIC TANK
PARKING LOT LIGHT (1 HEAD)
PARKING LOT LIGHT (3 HEAD)
PARKING LOT LIGHT (4 HEAD)
PARKING LOT LIGHT (2 HEAD)STANDARD DUTY ASPHALT
CONCRETE PAVEMENT
DISTRIBUTION BOX
ROW RIGHT OF WAY
BSL BUILDING SETBACK LINE
ESMT EASEMENT
D.&U.E.DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
12 PARKING COUNT
EXISTING ASPHALT
PAVEMENT
SITE PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
SECTION LINE REVISIONS AND ISSUESPart of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR:147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:SSRDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATEBY01.13.2020SSRDATE:SSRKnow what's below.
before you dig.Call
R APPROVAL PENDINGNOT FOR CONSTRUCTIONCARMEL SELF STORAGEISSUED FOR CITY REVIEW01.13.2020BJSW
S
N
E ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMSTEVEN SCOTT RUCKER, PE No. 11300279
01/13/2020