HomeMy WebLinkAboutLS200.0�i
CODE SUMMARY
1 I SCOPEOFWORK
OFFlCE REMODEL OF E%ISiW G SHELL SPACE
p PREVIOUSUSEOFSPACE B�USWESSf
3 OCCUPANCVCLASSIFlCAiION B�USWESSf
q CHANGEOFOCCUPANCVCLASSB NO
5 iOiALBUILDINGAREA VARIES SHFLOOR X SSiORIES = 142394SF
5 iOiALPROJECiAREA 2809 SF
� OCCUPANCVCALCUL4ilONS SPACEiVPE ARE4 SFPEROCCUPANi OCCUPLOAD
GEN.OFFlCE 2,809SF 100 29
iOiAL OCCUPANiS IN PROJECiAREA 29
8
9
10
11
12
13
14
15
ifi
NUMBER OF EXIiS
SPRINKLERSVSiEM �VES/NO�
iOiAL AREA OF ACCESSORY USES
iOiAL AREA ON iHE FLOOR
ACCESSORV AREA EXCEE9S 10%
FIRE WALLS, AND/OR OCCUPANCY
SEPARAiIONS �IF REQl11RED�
ASHRAE 90J Sl1MMARV
Bl11Li BEFORE 19I82
Bl11LDING CONSiRlICiION iVPE
REOUIRED:I PROVIDED:I
YES-EXISiINGiO REMAIN
0 SF
29,482 SF
NO
N/A
REQUIREMENiS W ILL BE MEi �SEE REFLECiED CEILWG PUNJ
NO
IIB
LEGEND
Ep EXISiINGELECiRICALPANELLOCAiION
EX EXISiING EXIi- BUILDING SiAIR LOCAiION
� FIRE EXiINGUISHER
� exirsicN
�,nu EMERGENCYLIGHi
--- iRAVELDISiANCE
LIFE SAFETY NOTES
I. PROVIDEEMERGENCYLIGHiINGINiENANiSPACEASREQUIREDPER
NEMA AND IBQ EMERGENCV BAIIERV PACKS OR LIGHiS
CONNECiED i0 AN EMERGENCY POW ER SOURCE ARE REQUIRED IF
iHE SPACE CONiAINS 50 PERSONS OR MORE. FIXiURES SHOW N ON
PLAN ARE FOR REFERENCE ONLY.
2 PROVIDEALARM NOiIFlCAiION APPIJANCES �HORNS/SiROBES�,
EMERGENCY SPEAKERS, SMOKE DHECiORS RRE PULLS, AND ANY
OiHER REQUIRED AL4RM & DEiECiION SVSiEMS AS NECESSARV i0
MEEi ALLAPPLICABLE CODES �INiERNAiIONAL BUILDWG CODE,
IMERNAiIONAL FlRE CODE NFPA�. IN RECEPiION AREAS,
CONFERENCE ROOMS AND OiHER HIGH PROFlLEAREAS WIiHIN SUIiE,
ALL LOCAiIONS OFSUCH DEVICES MUSi BEAPPROVED BYSDI OR
iENANi PRIOR i0I NSiALLAiION. FAI W RE i0 DO SO MAV RESULi IN
CONiRACiOR RELOCAiWG iHESE REMS Ai iHEIR E%PENSE.
3. FIRE EXiINGUISHERS: CONiRACiOR i0 ENSURE ALL NEW AND
EXISiING FlRE EX�INGUISHERS ARE INSiALLED ACCORDING i0 NFPA
10. COORDINAiE WIiH OWNER/LANDLORD ON E%iWGUISHER iVPE
AND HOUSWG. MAXIMUM iRAVEL DISiANCE OF JS FEEf FROM ANY
POINi i0 A VISIBLE EXiINGUISHER.
iH E FOLLOW ING NOiES APPLV ONLV W E%ISiING SPRW KLERED FACILIiIES.
4 FIRE PROiECiION WORK IS i0 BE PROVIDED BY DESIGN/BUILD
SERVICESUNDERiHEGENERALCONiRACi. PROVIDEACOMPLEiE
WORKINGSV4EM. SCHOII DESIGN, INC., IS NOi RESPONSIBLE FOR
iHE DESIGN, INSiALUiION, OR RENOVAiION OF iHE FlRESPRINKLER
SYSiEM.
5. iHE FlRE PROiECiION CONiRACiOR SHALL GENERAiE ALL REQUIRED
DRAW WGS AND SHALL FlLE iHOSE DRAW WGS AND REUiED
DOCUMENiS, W IiH iHE SiAiE AND LOCAL AUiHORIiIES HAVWG
JURISDICiION OVERiHEPROJECi.
GENERAL NOTES
LI. REFER iOARCHIiECiURAL PLAN FOR WALL iYPEAND CONSiRUQION
DEiAILS.
L2 E%ISiWG E%li SIGNS FlRE PULLS, FlRE E%iWGUISHERS ALARM
NOiIRCAiION APPLIANCES i0 REMAIN. RROCAiE EXISiING EXIi
SIGNS FlRE PULLS FlRE EXiINGUISHERS AND ALARM NOiIFlCAiIONS AS
REQl11RED i0 MEEi ALL LOCAL AND SiAiE CODES.
c
�
•� o
� � J
� N b � J
� Q o �
JJ
v�Z� .-
L - I� y
� J
� .� M .
P Qn 7
W O M J
O c
`n O p 3
� � 5
C
iHl$ DRA W ING. AND iH E IDEAS.
DFIGNS AND CONCEPiS CONiA W ED
HEREIN.AREiHEEXCLUSIVE
IMELLKiUAL PROPERtt OFSCHOii
DESIGN. WC..ANDARENOiiO BE
USED OR REPRODUCED IN W HOLE OR
IN PqRi, wIiHOUi iHf wRIIIfN
CONSENi OF SCHOII DESIGN.
�
�
N
W
H
N
� H O
� . �
� � �
r
N � z
VNJ
Zw
wa�
� u.i Q
�/i w U
>
0
�
M
ISSUE
DAiE DESCRIPiION
11.06.19 REVIEW SEi
11.18.19 PERMIiSEi
11.]5.19 BIDSEi
REVISIONS
MAR DAiE DB DESCRIPiION
IV �.
AR10700017
STATE OF
PROJECT NUMBER
2019.247
PROJ. MGR DRAWN BY
ACM JJ
2ND FLOOR
LIFE SAFETY
RELEASED FOR CONSTRl1CTI0N
Su6jec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
y\0.v��i �\p;,V'iiY?A�i
\
DATE: O� �ZZ�ZO
� neenNorwcoNrencr LIfC JNfCI l fLFiIV
� AREA OF WORK � ��
��
� � o0