HomeMy WebLinkAboutS6-001-GENERAL-NOTES-Rev.0� 1 2 � � 7 � GENERALNOTES: ALL CONSTRUCTION SHALL COMPLV WITH THE INTERNATIONAL BUILDING CODE 2012AS AMENDED BV INDWNA BUILDMG CODE. THE STRUCTURAL ENGMEERS OF RECORD ARE RESPONSIBLE FOR THE ADEpUACV OF THE STRUCTURAL DESIGN AS SHOWN M THE CONTRACT DOCUMENTS WHICH DEPICT THE STRUCTURE IN ITS COMPLETED FORM. THE STRUCTURE IS DESIGNED TO BE CAPABLE OF WITHSTANDING CODE PRESCRBED DESIGN FORCES AND FULLV STABLE WHEN THE STRUCTURE IS FULLV CONSTRUCTED (LE, FULLV BUILT). IT IS SOLELV THE RESPONSIBILITV OF OTHERS TO DETERMME ERECTION PROCEDURE AND SEpUENCE AS W ELL AS TO PROVIDE FOR THE SAFETV OF THE STRUCTURE AND ITS COMPONENTS PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF SHORING, SHEETING, TEMPORFRV BRAQNG, GUVS, TIE DOW NS, OR DEWATERING WHICH MIGHT BE NECESSARV. SUCH MATERIAL SHALL REMAM THE CONTRACTOR'S PROPERTV AFTER THE COMPLETION OF THE PROJECT. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL DRAW ING DIMENSIONS AND CRITICAL DIMENSIONS OF EXISTING STRUCTURE PRIOR TO WORK OR FABRICATION. ANV CONFLICTS OR DISCREPANCIES FOUND IN THE DRAWINGS OR SITE CONDITIONS SHALL BE PROMPTLV REPORTED TO THE ENGINEER. THE CONTRACTOR IS RESPONSBLE FOR MEETING ALL SAFETV STANDARDS. STRUCTURAL DESIGN DATA: DESIGN IS IN ACCORDANCE WITH THE INTERNATIONAL BWLDING CODE2012AND INDIANA BWLD CODE. WE LOADS' FLOORLOAD: LOBBIES AND FIRSLFLOOR CORRIDORS: 100 PSF UNIFORMLV DISTRIBUTED LNE LOAq 2000 POUND POINT LOAD. OFFICES: 50 PSF UNIFORMLV DISTRIBUTED WE LOAD 2000 POUND POINT LOAD. CORRIDORS ABOVE FlRST FLOOR:80 PSF UNIFORMLV DISTRIBUTED LIVE LOAD 2000 POUND POINT LOAD. NO LNE LOAD REDUCTIONS AREAPPLIED. ROOF LOAD: 20 PSF UNIFORMLV DISTRIBUTED LNE LOAD SNOW LOADS: GROUND SNOW LOAD 20 PSF (Pe)� FLAT-ROOFSNOW LOAD 20PSF (R)� SNOW LOAD IMPORTANCE FACTOR (�)_ 1_0 THERMAL FACTOR (C�): 1.0 WIND DESIGN DATA: BASIC WIND SPEED (3SECOND GUST): 115 MPH WIND IMPORTANCE FACTOR Qw): 1.0 RISK CATEGORV: II WIND EXPOSURE B MTERNAL PRESSURE COEFFICIENT (GCo;): 0.55 DESIGN W IND PRESSU RE FOR COM PON ENTS AND CLADDING NOT OTHERW ISE SPEQFlED: 100 PSF EARTHQUAKE DESIGN DATA: SEISMIC IMPORTANCE FACTOR Qe): 1.0 RISK CATEGORV: II SITE CLASS' C MAPPEDSPECTRALRESPONSEACCELERATIONS: Ss- 0.14] S�: 0.082 SPECTRAL RESPONSE COEFFICIENTS: Sos- 0.118 Sm 0.093 SEISMIC DESIGN CATEGORV: B BASIC SEISMIGFORCE-RESISTMG SVSTEMS: STEEL SVSTEMS NOT SPECIFICALLV DETAILED FOR SEISM IC RESISTANCE, EXC W DING CANTREVER CO W MN SYSTEMS DESIGN BASE SHEAR (V): 288 KIPS SEISMIC RESPONSE COEFFICIENTS (CS): 0.039 RESPONSE MODIFICATION FACTORS (R): 3 ANALVSIS PROCEDURE USED: EpUNALENT LATERAL FORCE PROCEDURE, LINEAR ELASTIC STATIC ANALVSIS SHOP DRAWINGS: THE CONTRACTOR SHALL REVIEW, STAMP WITH THEIRAPPROVAL, DATEAND SIGN ALL SHOP DRAWMGS REQUIRED BV THE CONTRACT DRAW INGS PRIOR TO SUBMITTAL TO THE ENGMEER. AT THE TIME OF SUBMISSION, THE CONTRACTOR SHALL INFORM THE ENGINEER IN WRITMG OFANV DEVIATION IN THE SHOP DRAWMGS FROM THE REQUIREMENTS OF THE CONTRACT DRAW MGS. AS A MINIMUM, SHOP DRAW MGS SHALL BE SUBMITTED FOR THE FOLLOWING: STRUCTURALSTEEL CONCRETE REINFORCEMENT CONCRETE FORMWORK COLD-FORMED STEEL FRAMING STEEL DECKING WHERE THE EXISTING STRUCTURE IS REMOVED FOR CONSTRUCTION, INSPECT AND REPLACE ANV DAMAGED MATERIAL BEFORE REINSTALLATION PER TH E ORIGINAL STRUCTURAL DRAW MGS. ABBREVIATIONS: CL CENTERLME °F DEGREESFAHRENHEIT DIA. DIAMETER MCH (E) EXISTING (N) NEW AQ AMERICAN CONCRETE INSTITUTE ASCE AMERICANSOCIETVOFCNILENGINEERS ASTM AMERICAN SOQETV FOR TESTING AND MATERWLS BOT BOTTOM C CHANNEL CET CRITICALEXPOSURETEMPERATURE CL COWMN CONC CONCRETE G CONTROLJOINT CJP COMPLETEJOMTPENETRATIONWELD CLR CLEAR,CLEARANCE DIA DIAMETER DO DITTO DWG DRAWING EF EACH FACE EE EACH END EJ EXPANSION JOINT EL ELEVATION EQ EQUAL,EQUALLV EW EACH WAV FDN FOUNDATION FT FULLVTENSIONED fM SPECIFIED COMPRESSIVE STRENGTH OF CLAV MASONRV OR CONCRETE MASONRV, PSI f�,� SPEQFlED COMPRESSNE STRENGTH OF AAC MASONRY, PSI GA GAUGE HOR¢ HOR¢ONTAL RELEA$ED FOR CONSTRACTION ;o E`couN�oii evaBunnoN`seRvice lDSFORCE Su6jec��ocompliancewithallregula�ions �DSPERSQUAREINCH of Sla�e antl Local Codes ONTAL CityofCarmel ]AL Y,:,,, w��:,��tiu�_.� DATE: OIIZZIZO MAX MIN MPII NTS OBC OC OP PL PSI PJP RBS REF REINF REOD REV SC SH SIM SME sn STD SVM T&B TOC TOS TYP UNO VERT w WP WT WWF xs 3 STRUCTURALSTEEL: MATERIALS: PLATES,ANGLES ASTM A36 C BEAMS ASTM A992, MIN VIELD POINT = 50 KSI WIDE FLANGE BEAMS ASTM A992, MIN VIELD POMT =50 KSI TUBE SHAPES (HSS) ASTM A500, GRADE C OR ASTM A1085 BOLTS ASTM F3125, GRADE A325 NUTS ASTM A563, GRADE DH HARDENED WASHERS ASTM F436 TENSION INDICATOR WASHERS ASTM F959,TVPEA325 WELD FILLER METAL MINIMUMTENSILESTRENGTH ]OKSI MINIMUMVIELDSTRENGTH 58KSI ELONGATION 22oMINIMUM SHOP PAINT ALL NEW STRUCTURAL, MISCELLANEOUS AND EMBEDDED STEEL, E%CEPT THOSE SURFACES IN CONTACT WITH CONCRETE, WITH ONE COAT OFAPPROVED PRIMER. ANV SCARRED AREAS SHALL BE TOUCHED UP W ITH THE SAME PAINT AFTER ERECTION. PAINT COLOR SHALL BE GRAY. ALLBOLTEDCONNECTIONSSHALLBESNUGTIGHTENEDJOINTSUNLESSNOTEDOTHERWISE. PROVIDEMECHANISM TO PREVENT NUTS IN SNUG-TIGHT JOWTS FROM BECOMING LOOSE (LOCK NUTQ LOCK WASHERS, JAM NUTS, BURRING THREADS AFTER INSTALLATION, ETC). PROVIDE STANDARD SIZE BOLT HOLES UNLESS NOTED OTHERWISE. GALVAWZE ALL ANCHOR BOLTS, NUTS, AND WASHERS IN ACCORDANCE WITH ASTM F2329. REPAIR ANV DAMAGED COATMGS IN ACCORDANCE WITH ASTM A]80. ALL ANCHOR BOLT NUTS SHALL BE INSTALLEDAS "SNUG TIGHT". PROVIDE LOCK WASHER BURR THREADS DOUBLE NUT OR TACK WELD TO PREVENT NUT FROM BECOMMG LOOSE. STEEL CONSTRUCTION SHALL CONFORM TO AISC 303-10. PROVIDE WASHERS WHEN REQUIRED BV THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC) "SPECIFICATION FOR STRUCTURAL JOINTS USMG HIGH STRENGTH BOLTS" THERE SHALL BE NO FIELD CUTTMG OF STRUCTURAL STEEL MEMBERS FOR THE WORK OF OTHER TRADES W ITHOUT THE PRIOR APPROVAL OF THE ENGINEER OR AS NOTED. ALL WELDMG SHALL CONFORM TO AWS D1.1. PROVIDE GROUT CONFORMING TO ASTM C1101 WHEN GROUT IS SPEQFlED ON THE DRAWINGS. STEEL DECK: STEEL DECK SHALL BE OF THE SRE AND TVPE NOTED ON THE PLANS. ALL STEEL DECKING SHALL CONFORM TO ANSIISDI RD-2010 STANDARDS. STEEL DECKING SHALL BE GALVANRED PER ASTM A653, G60 UN LESS NOTED OTHERW ISE. MINIMUMDECKGAGESARESHOWNONTHEPLANSANDAREBASEDON3-SPAN,UNSHOREDCONDITIONS. SHORING OR HEAVIER DECK MAV BE REpUIRED FOR OTHER CONDITIONS, DEPENDING ON THE MANUFACTURER'S AND CONTRACTORSLAVOUT. THEDECKSUPPLIERSHALLCONFIRMTHEDECKSIZEFORTHEACTUALLAVOUTAND PROVIDE THE ENGMEER OF RECORD W ITH ENGMEERING CALCULATIONS OR PUBLISHED MANUFACTURER'S DATA VERIFVING THE SPECIFIED DECK REpUIREMENTS. PROVIDE ENGINEERED AND CHECKED SHOP DRAW INGS INDICATMG LOCATION, GAGE, AND SIZE OF EACH PIECE OF DECKMG. THE DRAWMGS SHALL CLEARLV SHOW WELDING DETAILS TO STRUCTURAL FRAMING AND SIDE LAP CONNECTION DETAILS. WHEREVER POSSIBLETHE METAL DECK SHALL BE CONTINUOUS OVER ALL SPANS IN THE DIRECTION INDICATED. FASTEN CONCRETE TOPPED STEEL DECKMG TO UNDERLVMG SUPPORTS WITH HILTI X-ENP-19 FASTENERS WITH 3N]FASTENINGPATTERN. FASTENROOFDECKTOUNDERLVINGSUPPORTSWITH#12SCREWSORHILTIX-ENP-19 FASTENERS. ROOF DECK SIDE LAPS SHALL BE FASTED WITH A VERCO PUNCHLOC IIAT 121NCHES MA%IMUM ON CENTER. MAXIMUM MINIMUM MANUFACTURER'S PRMTED INSTALLATION INSTRUCTIONS NOT TO SCALE OHIO BUILDING CODE ONCENTER OPPOSITE HAND (MIRRORED) PLATE POUNDS PER SOUARE MCH PARTIAL JOINT PENETRATION W ELD REDUCED BEAM SECTION REFERENCE REINFORCING REpUIRED REVISION SLIP CRITICAL SHEET SIMILAR SUBJECT MATTER EXPERT SQUARE STANDARD SVMMETRICAL TOP AND BOTTOM TOP OF CONCRETE TOP OF STEEL TYPICAL UNLESSNOTEDOTHERWISE VERTICAL WIDE FLANGE ROLLED STEEL BEAM WORKING POMT STRUCTURALTEE W ELDED W IRE FABRIC EXTRA-STRONG � STRUCTURALCONCRETE: CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI301. CONCRETE SHALL HAVE A MAXIMUM WATER- CEMENT RATIO OF 0 45. SPEQFlED 28-DAV COMPRESSNE STRENGTH (f�):4000 PSI A CONCRETE STRENGTH TEST SHALL BE TH E AVERAGE OF THE STRENGTH OF AT LEAST TW O 6 INCH DIAMETER BV 121NCH TALL CVLINDERS OR AT LEAST THREE 41NCH DWMETER BV 81NCH TALL CVLINDERS MADE FROM THE SAME SAMPLE OF CONCRETE AND TESTED AT 28 DAVS. STRENGTH LEVEL OFAN INDNIDUAL CLASS OF CONCRETE SHALL BE CONSIDERED SATISFACTORV IF BOTH OF THE FOLLOW ING REQUIREMENTS ARE MET: A EVERV ARITHMETIC AVERAGE OFANV THREE CONSECUTIVE STRENGTH TESTS EQUALS OR EXCEEDS SPEQFlEDf�AND B. NO INDNIDUAL STRENGTH TEST FALLS BELOW f� BV MORE THAN 500 PSI W HEN f� IS 5000 PSI OR LESS; OR BV MORE THAN 0.10xC; WHEN C; IS MORE THAN 5000 PSI. CONCRETE SUPPLIED SHALL MEET THE REQUIREMENTS OF ACI 301-i6, SECTION 4 22 FOR EXPOSURE CATEGORIES F0, S0, W0, C0. CONTRACTOR SHALL SU BMIT A QUALITV CONTROL PLAN IN ACCORDANCE W ITH ACI 301. SELF-CONSOLIDATING CONCRETE IS ALLOW ED. PROVIDE CONTRACTION JOINTS IN ALL SLABS-ON-GRADE ATA MAXIMUM SPACMG OF 10 FEET. PROVIDE ISOLATION JOMTS AT ALL CO W MNS AN D WALLS. INSTALL 3l4" CHAMFERS ON ALL EXPOSED CONCRETE CORNERS. CURE CONCRETE USMG PONDMG, CONTINUOUS FOGGMG, CONTINUOUS SPRINKLMG, OR APPLICATION OF MATS OR FABRIC KEPT CONTINUOUSLV WET. CURE CONCRETE FOR THE LESSER OF SEVEN (]) DAVS AFTER PLACEMENT OR UNTIL THE CONCRETE HAS ATTAMED A STRENGTH EQUAL TO AT LEAST ]0 % OF f� FOR FlELD-CURED TEST SPECIMENS IN ACCORDANCE WITH ASTM C31 TESTED IN ACCORDANCE WITH ASTM C39. MTERIOR CONCRETE SLABS ON GRADE SHALL BE TROWEL FINISHED. EXTERIOR CONCRETE SLABS OR FLATWORK SHALL BE BROOM FINISHED. FORMED SURFACES SHALL BE SURFACE FINISH-20 (SF20) IN ACCORDANCE WITH ACI 301-16, SECTION 5.3.3.3.b. PROVIDEA RUBBED FINISH FORALL FORMED SURFACES. ALLCONCRETEFORMWORKSHALLCONFORMTOTHEREQUIREMENTSOFACI301-16. SUBMITMANUFACTURER'S DATASHEET ON FORM TIES, EXPANSION JOINT MATERIAL, WATERSTOP MATERIALS AND SPLICES IN ACCORDANCE WITHACI301-i6,SECTION2.t22 FlELD-CUREDTESTSPECIMENSMUSTATTAINASTRENGTHEQUALTOf�PRIORTO REMOVMG FORMWORK THAT SUPPORTS CONSTRUCTION LOADS OR THE W EIGHT OF STRUCTURAL MEMBERS. GROUT SHALL BE IN ACCORDANCE WITH ASTM C1101. ALL CONCRETE REINFORCEMENT SHALL CONFORM TO THE REQUIREMENTS OF ACI301 SECTION 3. ALL REMFORQNG STEEL BARS SHALL BE ASTM A6150R A106. MINIMUM VIELD STRENGTH OF STEEL BARS (fy) =60 KSI REMFORQNG STEEL SHOULD BE DETARED AND PROVIDED SUCH THAT THE NUMBER OF SPLICES ARE MINIMRED. LAP SPLICES SHALL BE CLASS B SPLICES UNLESS OTHERWISE NOTED. WHERE SPLICMG IS REQUIRED, THE FOLLOW ING MINIMUM SPLICE LENGTH IN INCHES SHALL BE PROVIDED: CLASSA CLASSB #3 BARS 19 25 i74 BARS 25 33 #SBARS 31 41 d6BARS 3] 49 #1BARS 54 �1 i!8 BARS 62 81 d9 BARS ]0 91 #10 BARS �9 f02 #11 BARS 8] 114 #140RLARGERBARS NOTPERMITTED NOTPERMITTED BENT BARS SHALL BE COLD BENT. HEAT-BENDING IS NOT PERMITTED. BENDS SHALL BE "STANDARD HOOKS" IN ACCORDANCE WITH ACI301 SECTION 3 UNLESS NOTED OTHERWISE. FIELD WELDMG OF REINFORCEMENT IS NOT PERMITTED UNLESS SPECIFICALLV NOTED OTHERWISE OR PERMITTED IN WRITING BY THE RESPONSIBLE ENGINEER OF THE DESIGN DRAWINGS. WELDED W IRE MESH SHALL CONFORM TO THE REQUIREMENTS OF ASTM A185. WELDED WIRE MESH SHALL BE 2x2-W4xW4 UNLESS NOTED OTHERWISE SPLICE LENGTH FOR WELDED WIRE MESH SHALL BE 12 MCHES UN LESS NOTED OTHERW ISE. ADHESIVE ANCHORS SHALL BE HILTI HIT-HY 200 ADHESNE ANCHORING SYSTEM CONFORMING TO THE REQUIREMENTS OF ICGES ESR318] FOR THE MANUFACTURE AND INSTALLATION OF THE ANCHOR SVSTEM. ALL THREADEDRODSHALLBEASTMF1554,GRADE36. NUTSSHALLCONFORMTOTHEREQUIREMENTSOFASTMA563A. ALL THREADED ROD SHALL BE CLEAN, STRAIGHTAND CONTINUOUSLY THREADED WITH UNC COARSE THREADS. INSTALL ALLANCHORS WITH 4" EFFECTNE EMBEDMENT UNLESS NOTED OTHERWISE. ALL HOLES SHALL BE HAMMER DRILLED. ANCHORS SHALL BE INSTALLED UNDER "DRV HOLE" CONDITIONS. THE MINIMUMALLOWABLE AGE OF THE CONCRETE IS 21 DAVS. ALTERNATIVELV, DEWALT AC200+ EPDXV ADHESIVE ANCHORAGE CONFORMING TOTHE REQUIREMENTS OF ICGES ESR-4021 MAV BE SUBSTITUTED WITH THE SAME EMBEDMENT DEPTH. SPECWL INSPECTION IS REQUIRED AS SPEQFlED IN THE ICGES REPORT. "DRV HOLE" MEANS THAT THE CONCRETE HAS NOT BEEN EXPOSED TO MOISTURE FOR THE PRECEDMG 14 DAVS. �i STRUCTURALMASONRV SEE SPECIFlCATIONS FOR ADDITIONAL MFORMATION NOT PROVIDED IN THE SECTIONS BELOW. MATERIALS: a. ALLCONCRETEMASONRVUNIT�CMU)WALLASSEMBLIESSHALLHAVEAMINIMUMCOMPRESSNESTRENGTH (fm) OF 2000 P51, U NLESS OTHERW ISE NOTED. b. REMFORQNGSHALLBE6RADE605TEELCONFORMINGTOASTMA615,UNLESSOTHERWISENOTED. CONSTRUCTION: a. ALL MASONRV WALLS SHOWN ON STRUCTURAL PLANS ARE LOAD-BEARING, UNLESS NOTED OTHERWISE. b. SEEARCHITECTURALDRAWINGSFORALLOPENINGDIMENSIONSANDLOCATIONS. c. ALLCELLSWITHVERTICALREINFORQNGANDALLBONDBEAMSSHALLBESOLIDGROUTEDPERTHEFULL HEIGHT AND WIDTH OF WALL IN WHICH THEV ARE LOCATED. d. MTERIOR CMU PARTITION WALLS SHALL BE PARTIALLY GROUTED. ALL CELLS WITH VERTICAL REINFORQNG AND BOND BEAMS WITH HORIZONTAL REINFORCING SHALL BE GROUTED SOLID. LINTELS SHALL BE GROUTED SOLID FOR THE DEPTH EQUAL TO HALF THE OPENING WIDTH BELOW UNLESS OTHERW ISE NOTED. e. COMPRESSNESTRENGTHOFCMUASSEMBLIESSHALLBEVERIFlEDBYPRISMTESTINGBEFOREANDDURING CONSTRUCTION. C RUNNING BOND SHALL BE USED FORALL MASONRV WORK UNLESS OTHERWISE NOTED. g. SEE ARCHITECTURAL DRAWINGS FOR MASONRY VENEER JOINT LOCATIONS. h. HOLLOW MASONRV UNITS SHALL BE LAID WITH FULL MORTAR COVERAGE ON HORIZONTALAND VERTICAL EDGES OF FACE SHELLS. W EBS SHALL ALSO BE BEDDED IN MORTAR AT ALL UNITS. i. GROUTING OPERATIONS FOR ANYSECTION WALL SHALL BE COMPLETED OVER 1-DAY DURATION WITH NO INTERRUPTIONS M GROUTMG PLACEMENT GREATER THAN 1-HOUR. GROUT PLACEMENT SHALL BE STOPPED 1%" BELOW THE TOP COURSE OF BLOCK OR %" BELOW THE TOP OF BOND BEAMS TO BE COMPLETED DURMG THE OPERATIONS THAT DAY TO FORM A KEY. REINFORCMG: TVPICAL REINFORCMG 8" CMU: VERTICALBARS: NSAT24"O.GATCENTERLME HORIZONTALBARS 2 #4xCONTATB'-0"O.GINBONOBEAMS (1 12" CMU (EXTERIOR WALLS): VERTICAL BARS: #6 AT 24" 0. Q AT EACH FACE HORIZONTALBARS: (21#4xCONTAT4'-0"O.GINBONOBEAMS 12" CMU (INTERIOR WALLS): VERTICAL BARS: #6 AT 24" 0. C AT EACH FACE HORIZONTALBARS: (21#4xCONTATB'-0"O.C.INBONDBEAMS a. MINIMUM WALL REINFORCMG NOTED IN THIS SECTION SHALL BE PROVIDED TVPICALLV, UNLESS OTHERWISE NOTED ON PLANS, DETAILS AND WALL ELEVATIONS: b. PROVIDE JOINT REMFORCING ATALL WALLS PER SPECIFlCATIONS IN ADDITION TO HORRONTAL REMFORCING REQUIREMENTS. c. WHERESINGLEBARHORIZONTALREINFORCINGISPROVIDED,STAGGERTHEPLACEMENTOFTHEBARS EITHER SIDE OF THE VERTICAL BARS OVER THE HEIGHT OF THE WALL. d. PROVIDEADDITIONALREINFORCMGATWALLENDS,OPENMGJAMBSANDINTERSECTIONS. e. ADDITIONAL VERTICAL REMFORQNG EACH SIDE OF OPENINGS SHALL RUN CONTINUOUS BETW EEN FOUNDATION AND FLOOR/ROOF AND FLOOR-TO-FLOOR/ROOF UNLESS SPEQFICALLV NOTED OTHERWISE. C WHEN EACH FACE VERTICAL REINFORQNG IS REQUIRED PLACE BAR CENTERLWES 2 Y8"FROM EACH FACE OF MASONRV, UNLESS OTHERWISE NOTED. LINTELS SHALL BE REMFORCED W ITH 21 k5 X CONTINU0U5 HORRONTAL 8AR51N LWTEL BLOCKS UNLESS 9. ( OTHERW ISE NOTED (SEE ELEVATIONS} EXTEND THE REINFORQNG 3'=4'PAST THE EDGE OF OPENING BELOW, EACH SIDE, WITH STANDARDACI90 DEGREE DOWNWARD HOOKS. WHERE LESS THAN 3'-0"IS NOT AVAILABLE BEFORE AN ADJACENT WALL END OR OPENING, EXTEND REINFORQNG T03" QFAR FROM ADJACENT WALL END OR OPENING EDGE AND PROVIDE STANDARD 90-DEGREE DOWN WARD HOOK. THIS MINIMUM LINTEL REMFORQNG IS REQUIRED AT ALL NON-LOAD BEARING WALL AND INTERIOR PARTITION LINTEL CONDITIONS AS WELL ALL LINTEL BEAMS SHALL HAVE A MINIMUM DEPTH OF 241NCHESAND SHALL BE GROUTED SOLID FOR THEIR FULL LENGTH INCLUDING 3'-4"PAST EACH OPENING EDGE, FOR BOTH LOAD AND NON-LOAD BEARING WALLS APPLICATIONS. h. LINTELSSHALLHAVEk4VERTICAL8AR5TIRRUP5ATi6"ONCENTERABOVETHEOPENING,UNLESSNOTED OTHERW ISE. THESE BARS SHALL HAVE 180 DEGREE HOOKS AT THEIR ENDS ABOVE THE OPENING; 31NCHES CLEAR, WITH HOOK DIRECTIONS ALTERNATING WITH EVERV OTHER BAR. THESE BAR EXTEND 481NCHE5 MINIMUMABOVE THE OPENING; WHERE 481NCHES IS NOTAVAILABLE, PROVIDE 135 DEGREE HOOKS AROUND TOPCOURSEBONDBEAMREINFORCMG. FORLINTELSECTIONSABOVEOPENMGSTHATAREGREATERTHAN 48 WCHES TALL, PROVIDE TVPICAL VERTICAL AN D HORIZONTAL REIN FORCMG IN ADDITION TO THE it4 VERTICALBARSTIRRUPSDESCRBEDABOVE LMTELSTIRRUPREINFORQNGSHALLBEPROVIDEDATBOTH LOAD AND NON-LOAD BEARWG WALL APPLICATIONS. i. SILLS SHALL BE REINFORCED WITH (2) tlSXCONTINUOUS HORIZONTAL BARS IN BOND BEAMS AND EXTENDED 3'-0"PASTTHEEDGEOFOPENINGABOVE,EACHSIDE WHERELESSTHAN3'-0"ISNOTAVAILABLEBEFOREAN ADJACENT WALL END OR OPENMG, EXTEND REINFORCMG TO 3"CLEAR FROMADJACENT WALL END OR OPENING EDGE AND PROVIDE STANDARD 90-DEGREE DOWN WARD HOOK. j. PROVIDETWOCOURSESOFBONDBEAMSWITH/DN4XCONTINUOUSHORIZONTALREINFORCINGBARSEACH (4 TOTAL) MINIMUMAT EACH FLOOR AND ROOF LINE SUCH THAT ONE FULL MASONRV COURSE OCCURS BELOW THE BOTTOM OF DECK ELEVATION, UNLESS NOTEo OTHERW ISE. k. PROVIDE ONE BOND BEAM WITH lD N4 XCONTINUOUS HORIZONTAL REINFORCING BARS AT TOPS OF WALLS. I. ATCORNERS,PROVIDEADDITIONALCORNERBARSTOMATCHTHESIZEANDSPACWGHORIZONTALWALL REINFORCMG, UNLESS OTHERWISE NOTED. THE LEGS OFTHE CORNER BARS SHALL BE MINIMUM OF ONE LAP LENGTH EACH WAV FROM A STANDARD ACI REINFORCING BEND AT THE CORNER AND MATCH THE CONFIGURATION OF THE WALL CORNER PLAN LAVOUT. m. SEE DRAWMG DETAIL SHEETS FOR ADDITIONAL REINFORCMG REQUIREMENTS; ESPECIALLVAT JOIST, BEAM AND GIRDER CONNECTION LOCATIONS. n. FOUNDATIONDOWELSSHALLBEPROVIDEDTOMATCH,ONE-FOR-ONE,THESIZEANDSPACMGOFTHE VERTICAL WALL REMFORCMG ABOVE THE DOW ELS EMEND UPWARDS FROM THE TOP OF FOUNDATION OR FOUNDATION WALL TO PROVIDE ADEQUATE LAP LENGTH W ITH THE VERTICAL WALL BARS PER THE SCHEDULE BELOW AN D EXTEND DOW N WARD TO BE 3"CLEAR FROM THE BOTTOM OF FOOTMG W ITH STANDARD ACI 318 90-0EGREE HOOKS, TYPICAL UNLESS NOTED OTHERWISE DOWELS FROM FOUNDATION OR FOUNDATION WALL SHALL BE INSTALLED VERTICAL, NO MORE THAT i HORRONTAL TO 6VERTICAL OUT OF PLUMB. o. DOWELS PERPENDICULARTO MASONRV WALLS FOR SLABS OR OTHER CONCRETE CONSTRUCTION SHALL HAVE STAN DARD ACI 318 90-0EGREE DOW N WARD HOOKS AROU ND HORIZONTAL REMFORCMG AN D SHALL EXTEND A LAP LENGTH INDICATED IN THE SCHEDULE BELOW FROM THE FACE OF MASONRV WALL, UNLESS OTHERWISE NOTED. DOWELS SHALL BE SPACED TO MATCH THE VERTICAL WALL REINFORCMG BELOW THE SLAB BEING CONNECTED, UNLESS OTHERW ISE NOTED. p. ALL CELLS OFALL LOAD-BEARING WALLS SHALL BE FILLED SOLID WITH CONCRETE GROUT FOR THE FULL LENGTH AND HEIGHT OF THE WALLS. q. ALL VERTICAL AND HORIZONTAL REMFORQNG IS CONTINUOUS. PROVIDE LAP SPLICES AS REQUIRED FOR THE LENGTHS INDICATED IN THE SCHEDULE BELOW. COORDINATE LAP SPLICE LOCATIONS W ITH FLOOR ELEVATIONS, TOPS OF WALLS AND LMTEL HORIZONTAL REINFORQNG AS REQUIRED; SEE WALL ELEVATIONS FOR ANV SPECIFlC LOCATIONS AS INDICATED. r. ALL REMFORQNG STEEL SHALL BE SECURED AGAINST DISPLACEMENT PRIOR TOAND DURING GROUTING OPERATIONS BY W IRE POSITIONERS. POSITIONERS SHALL BE SPACED AT 24" ON CENTER ALONG EACH VERTICAL BAR LOCATION. s. REMFORQNG BARS IN MASONRV WALLS SHALL NEVER BE CUT TO ALLOW FOR WORK FROM OTHER TRADES W ITHOUT PRIOR APPROVAL FROM TH E STRUCTURAL ENG W EER OF RECORD. LAP SPLICE SCHEDULE VERTICAL TENSION AND COMPRESSION BARS: BARSRE #4 #5 #6 #1 #8 #9 LENGTH QN.) 24 40 49 91 108 143 HORIZONTAL TENSION AND COMPRESSION BARS: BARSIZE #4 #5 LENGTH QN.) 3] ]0 a. SPLICES OF VERTICAL BARS SHALL BE PLACED NEXT TO EACH OTHER IN PLAN TO MAMTAM THE SAME CLEAR DISTANCE TO THE FACE OF THE MASONRV BLOCK UNITS, NOT INSET INTOTHE CELL SUCH THATTHE CLEAR SPACMG BETWEEN ADJACENT BARS IS REDUCED. b. SPLICES OF HORIZONTAL BARS SHALL BE PLACED ABOVE OR BELOW THE BAR TO BE SPLICED TO MAWTAIN THE SAME CLEAR DISTANCE TO THE FACE OF THE MASONRV BLOCK UNITS, NOT INSET INTO THE CELL SUCH THAT THE CLEAR SPACMG BETWEEN ADJACENT BARS IS REDUCED. ANCHORS: a. ALL POST INSTALLEDANCHORS SHALL BE INSTALLED INTO SOLID-GROUTED MASONRV CELLS PER MANUFACTURERS RECOMMENDATIONS. b. EXPANSION AND EPDXY ANCHORS SHALL BE THE S2EAND EMBEDMENT LENGTH AS SPECIFlED ON THE DRAW INGS. PROVIDE ANCHORS WITH THE FOLLOW MINIMUM ALLOWABLE STRESS DESIGN CAPACITIES: TENSION = 1500POUNOS; SHEAR= f000 POUNOS c. CAST ANCHORS AND BOLTS SHALL BE INSERTED INTO WALL FOR THE EMBEDMENT DEPTH SHOWN IN THE DRAWING DETAILS, Y'MINIMUM, AND SURROUNDING CELLS WITHIN LS TIMES THE EMBEDMENT DEPTH SHALL BE GROUTED SOLID TO ENCAPSULATE THE ANCHOR. SUBMITTALS: SUBMIT SHOP DRAWINGS THAT DEPICT REMFORQNG LAVOUT FOR CMU WALLS THAT INDICATE THE TVPICAL REINFORQNG AND ADDITIONAL REINFORQNG REQUIREMENTS CALLED FOR IN THE STRUCTURAL DRAW INGS AND SPECIFICATIONS. MISCELLAN W US: a EMBEDDEDPLATESWITHHEADEDSTUDS,ANCHORRODSORDEFORMEDBARANCHORSSHALLBEWETSET IN BOND BEAMS, AFTER GROUT PLACEMENT WHRETHE GROUT IS STILL PLASTIC. b. PRIOR TO INSTALLING HOLES GREATER THAN 4 MCHES IN DIAMETER IN MASONRV WALLS THAT WERE NOT SPEQFlCALLV DESIGNED FOR IN THE STRUCTURAL DRAWINGS, CONTACT STRUCTURAL ENGMEER OF RECORD FOR APPROVAL AND INSTALLATION REQU IREMENTS February 1, 2019 - ISSUE FOR PERMIT ,._ ��S� + ♦ 1 V WQ�i3LRE C2T �ncxmsc+�� �xcxsaixc�csou�+ui 76351nteractive Way Suite 100 � Indianapolis, IN 462%a 317.299.7500 FAX: 317.291.5805 �y � � � s 7 a O � 3 3 � 0 � � �O � � � � �O � �O � '��y P Ci[-�:. e�'� e � � c �`��",_ Y, - trt t ' �`- � � /� IP hA �� �r �; f` �.. � ., � �/OPIA�E��' �� ��: C �:j � �^` W � � O � �^ � � � � .� W U U O� � Q �� Q V � � ^ �, � � � � J � � � .� W W U � O L Q � Q Proi. No.: 077392 Date: 02/01 /19 A Sheet Name: GENERALNOTES ����Z�� K � rn c K m � N m �n �o m N v U m c `o m C o O c N N i � m � � U `�Jssuances: