HomeMy WebLinkAboutA6-002-PARTITION-TYPES-Rev.12"� , 2 3 0 1 i,-. � STRUCTUREABOVE 35/8"DERECTIONTRACK � - CONTINUOUSSEALANTBOTHSIDES. PROVIDE SMOKE OR FlRE RESISTANT SEALANT ACCORDING TO THE - PARTITION'SRATING. �� � �0 - � SCHEDULED CEILING (2)LAVEkS5/B"GWB(PAIN� ��. I ULU-0120NLV I -�:.I ����_.��'��; I SOUNDATTENUATIONBATTS _ ���-�"�� 35/8"METALSTUDSATi6"O.C. .........._.�� I � -� � CONTINUOUS398"RUNNER 5/8"GWB(PAINT) � �- I I I BASEASSCHEDULED FLOORFlNISHAS � . I. -' I � CONTINUOUSSEALANTBOTHSIDES FLOORFlNISHAS SCHEDULED � ' � PROVIDESMOKEORFlRERESISTANT SCHEDULED " SEALANTACCORDINGTOTHE TOP OF SLAB - II -� IIIV �� PARTITION'S RATING. TOP OF SLAB — � STRUCTUREABOVE � CONTINUOUSSEALANTBOTHSIDES. — PROVIDE SMOKE OR FlRE RESISTANT SEALANT ACCORDING TO THE PARTITION'S RATING. OJ, :�0 � SCHEDULED CEILING 2 1/P' METAL C-H STUDS AT 24" O.C. 5/8" GWB (PAINT) _. _ 1"GWB(PAWT) CONTINUOUS RUNNER BASEASSCHEDULED CONTINUOUS SEALANT BOTH SIDES. PROVIDE SMOKE OR FlRE RESISTANT SEALANT ACCORDI NG TO THE PARTITION'S RATING. (2) LAVERS 5/8" GWB (PAINT) UL U-412 ONLV � NORATING-STC49 14h 1-HOUR FIRE RATED - UL U419, NO SOUN� BATTS 1-2h 2HOUR FIRE RATED - UL U412, NO SOUN� BATTS 4 �e , STRUCTUREABOVE 35/8"DEFLECTIONTRACK � '� CONTINUOUSSEALANTBOTHSIDES. PROVIDE SMOKE OR FIRE RESISTANT SEALANTACCORDING TO THE PARTITION'S RATING. 0 \ � SCHEDULED CEILING � 35/8"METALSTUDSATi6"O.C. 5/8" GWB (PAINT) FLOORFlNISHAS — SCHEDULED TOP OF SLAB z NUOUS 3 98" RUNNER ASSCHEDULED N� " X 14 X 14 X q FURRING,NORATING 1 � JLED CEILING =ORCED CMU (PAWT) NOTE: � GROUT CELLS SOLID, FLOOR TO CEILING, WHERE F�ooR FiNisH ns ELEVATOR RAIL SUPPORT SCHEDULED BRACKETS ARE ANCHORED. TOPOFSLAB COORDINATE WITH ELEVATOR MANUFACTURER. � r� . . � . . .. � ��� . ��. . . � i0 5 NO RATING 5 2h 2HOUR FIRE RATED UL U905 � . , . . .. . ' � . . . . . � . .. .. . , .� , , . . . . 5 3 ' � STRUCTUREABOVE 35/8"DERECTIONTRACK _ �'— CONTINUOUSSEALANTBOTH SIDES. PROVIDE SMOKE OR FlRE RESISTANT SEALANT ACCORDING ��\/�T TOTHEPARTITION'SRATING. �' SCHEDULED CEILING 3 5/8" METAL STUDS AT 16" O.C. SOUND ATTENUATION BATTS 5/8" G W B (PAINT) FLOOR FlNISH AS SCHEDULED TOP OF SLAB — �[� � �ONTINUOUS 3 5/8" RUNNER 3ASE AS SCHEDULED �ONTINUOUS SEALANT BOTH iIDES. PROVIDE SMOKE OR FIRE 4ESISTANT SEALANT ACCORDING �O THE PARTITION'S RATING. W .� ¢ x � U e �� m ro 3 I ACOUSTIC CHASE PARTITION: STC 51 � a � 7 � � PARTITION TYPE LEGEND: FIRE R4TING: s - SMOKE 1h - 1-HOURFIRE 2h - 2-HOUR FIRE 1. ALLPARTITIONSTOBEMUDANDTAPEDAMINIMUMOF6"ABOVE CEILING 2 ALLPARTITIONSTOE%TENDTOUNDERSIDEOFDECKABOVE UNLESS OTHERWISE NOTED. 3. ATMETALSTUD/GVP PARTITIONS: PROVIDE MOISTURE RESISTANT GVPSUM BOARD AT WET WALLS AND PLUMBING LOCATIONS. 4. ATMETALSTUD/GVPPARTITIONS:PROVIDECEMENTBOARDWLIEU OF GVPSUM BOARD ATAREAS TO RECEIVE CERAMIC TILE WALL FlNISH. 5. SEESHEETA-003FORTVPICALPARTITIONDETAILSANDBACKING PLATE DETAILS FOR WALL MOUNTED ITEMS. 6. ALLSOUNDPARTITIONSTOBEMUDANDTAPEDTODECKABOVE AS REQUIRED TO MEETSTC RATINGS FLUTES FROMTOP OF TRACK TO DECK SHALL BE FlLLED W ITH SOUND ATTENUATING BATT INSULATION. ]. ALL FIRE RATED PARTITIONS TO BE MUD AND TAPED TO DECK ABOVEAS REQUIRED TO MEET FlRE RATINGS FLUTES FROM TOP OF TRACKTO DECK SHALL BE FlLLED WITH FlRE SAFlNG BATTS. 8. ALLMETALSTUDSTOBE20GAUGEMIN.U.N.O.-INCLUDINGALL PARTITIONS AT CASE WORK, OR OTHER WALL HUNG EQUIPMENT QNCLU�ING NJ.G EQUIPMENT), OR FIXTURES 9. PROVIDEMIN.CAULKJOINTANDGVPSUMBOARD"J-MOLDING"AT ALL TERMINATIONS OF GVPSUM BOAR� TO �ISSIMILAR MATERIALS (i e. WINDOW, DOOR, AND LOWER RETURNS, ETC.) U.N O. 10. ALL INTERIOR DOORS SH4LL HAVE HINGE SIDE DIMENSION FROM INTERSECTING PARTITION TO DOOR FRAME EDGE OF 4" AT GVPSUM PARTITIONS AND 8" AT CMU PARTITIONS, TVP. U.N.O. 11. ALL VERTICAL 3SI8" METAL STUD FURRING (PARTITION TVPE "4") SHALL BE BRACED WITH BACKING PLATES @ 8'-0" o.c. MIN. VERTICALLV W ITH THE BACKING PLATES BRACED BACK TO EXTERIOR METAL STUD WALL @ 32" o c. HORIZONTAL. TVP. 12. PER CODE -"SMOKE BARRIER" PARTITIONS SHALL RESTRICT THE PASSAGE OF SMOKE BETW EEN AREAS, BE TIGHT TO DECK ABOVE, HAVE SPECIAL DOOR AND MECHANICAL REQUIREMENTS. REFER TO GI003, DOOR SCHEDULE, AND MECHANICAL DRAWINGS. 13. PERCODE-'SMOKEPARTITIONS"SHALLLIMITTHEPASSAGEOF SMOKE BETW EEN AREAS, BE TIGHT TO DECK ABOVE, AND HAVE SPECIAL DOOR REQUIREMENTS. REFER TO GI003AND DOOR SCHEDULE. IF. �y �� ��: C �:3 \,f I "_�'` WQ�i3LRE C2T .ncxmsc+�ns�rcixsaixc�csow.n.i 76351nteractive Way Suite 100 Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 � � s 7 a 0 3 � 0 � � � �O � � � � � � � � �^` W ��\ it O W �^` W � � � .� W � U�' � � _ �� � � U �— � � 0 m � C N Q � � o � � U N t+�i O � O L � �� � � p �� o� � � � o� " o � �; � �� c� � �, _ J Q s c10i `�Jssuances: PEV OESCPIPIION OATE 1 A51 Ni 0&21/19 2 AS17k2 08/2&19 Proi. No.: 077392 Date: OS/OS/19 � a RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel Y,:,,, w��:,,�zti„�.1 DATE: OIIZZIZO July 1, 2019 — ISSUED FOR CONSTRUCTION STRUCTUREABOVE IG1 Sheet Name: PARTITION TYPES A6-002 ��_q�� ��_q. 2-2h 2HOURFIRERATED-ULU415 5