Loading...
HomeMy WebLinkAboutE101-STANDARD-SYMBOL-LEGEND-Rev.0, z 3 Y .�. s G � � SYMBOL LEGEND OUTLEf3 � SINGLE RECEPrACLE W SrANDARD DUPLE% RECEPrACLE QDwP WEATHERPROOF RECEPTACLE WcF� cRouNo Fnu�r RECEPTnc�E W�� ISOLAiED GROUND RECEPrACLE QDEWO ELECTRIC WATER COOLER W� RECEPTACLE ON DEDICATED CIRCUIT W� RECEPiACLE WIiH INiEGRAL USB PORi � DOUBLE DUPLEX RECEPTACLE (QUAD) Q CLOCK RECEPTACLE Q60A SPECIAL EQUIPMENT RECEPTACLE OR CONNECTION 4 TWIST LOCK TYPE RECEPTACLE ♦ WALL MOUNTED TELEPHONE � 60" A.F.F. (ROUGH-IN ONLY) � DATA OUTLET (ROUGH-IN ONLY� 0 DUPLEX COMMUNICAiION OUTLEi (VOICE & DATA� (ROUGH-IN ONLY� ■TP PowER Po�E (PowER, rE�EPHONE, onrn) ❑O JUNCTION BOX �j WALL MOUNTED (POWER) PURNITURE CONNECTION TO PARTITIONS � WALL MOUNTED (DATA) FURNITURE CONNECTION TO PARTITIONS �PLOOR BOX WITH DUPLEX RECEPTACLE AN� VOICE�DArA OUTLET q� PLOOR BOX WITH DUPLEX RECEPTACLE, VOICE/DATA OUTLET AND A/V OUTLET � POKE THROUGH DEVICE SWffCHES $ SINGLE-POLE SWITCH $� DOUBLE-POLE SWITCH �3 THREE-WAY SWITCH $° FOUR-WAY SWIiCH $W WMB. SWITCH�DUPLEX RECEPiACLE � THERMAL OVERLOAD SWIiCH �u MANUAL MOTOR SWITCH $K KEY SWIiCH $� WEATHERPROOF SWIrCH $T TIMER SWITCH �Mc MOMENTARY CONTACT SWIrCH �o DIMMER SWITCH (WATTAGE SHOWN� � TOGGLE �ISCONNECi SWITCH $�v LOW VOLTAGE PUSHBUTiON SWITCH �os WALL MOUNTED OCCUPANCY SENSOR os CEILING MOUNTEO OCCUPANCY SENSOR pp MOTION SENSOR POWER PACK Q REVISION NOTE F# FEEDER NOTE O KEY NOTE LIGHT FIXTURES � 2'x2' LAY-IN FIXTURE � 7x4' LAY-W FlXTURE I--�� SiRIP FIXTURE -r�- WALL MOUNTED FIXTURE '0' PENDANT MOUNTED FIXTURES O N�� NicHt ucHr (oN coNnNuous) � RECESSED, EMERGENCY FIXTURE QpJ, RECESSED DOWNLIGHT f0 RECESSED WALLWASH O SURFACE MOUNTED DOWNLIGHT � EXIT FIXTURE (arrows indicates direction of egress) � EXIT FIXTURE, WALL MOUNTED � EXIT RXTURE wITH TWIN HEAD EMERGENCY LIGHTS g EMERGENCY EGRESS LIGHT i EMERGENCY REMOTE HEAD ¢ WALL MOUNiED FlXTURE v v v LIGHT TRACK W/ LIGHT TRACK FIXTURE � DOCK LIGHT ^�❑ POLE FIXTURE .Q GROUND MOUNTED PLOODLIGHT jX BOLLARD CIRCUffRY and RACEWAYS CONDUIT INSTALLED (UNDER SLAB OR UNDERGROUND) CON�UIi INSiALLED (CONCEALE� IN WALL, ABOVE CEILING OR E%POSED) � � LOW VOLTAGE WIRING � CONDUIT UP CON�UIi DOWN HOME RUN (WITH PANEL DESIGNATIONS LPt-1,3,5� AND CIRCUIT NUMBERS) 1i, CON�UCTORS (GROUND = LONG LWE W� DOr, i� NETURAL = LONG LWE, PHASE = SHORT LWE� #12AWG CONDUCTOR SIZE (UNO) ] END OF RUN, CAP AND SiAKE � "RUN CONTINUES" INDICATION �� FLEXIBLE PIGTAILS/CONNECTIONS m PWGMOLD sw aw BUS WAY TM n+ CABLE TRAY RRE ALARM ❑F PULL STATION F� COMBINATION HORN AND STROBE -0s p DUCT DETECTOR 5� SMOKE DETECTOR � HEAT DETECTOR F�o���P� RRE ALARM CONTROL PANEL F�o�A�P� FIRE ALARM ANNUNCIATOR PANEL JI�E.o.�. END OF LINE DEVICE DI STROBE ONLY RRE ALARM DEVICE DH DOOR HOLDER FC FIREFIGHTER COMMUNICATION JACK FS FLOW SWITCH rs TAMPER SWITCH Piv POST INDICATING VALVE 0 EXTERIOR BELL eo BEAM DETECTOR eo BEAM DETECTOR REFLECTOR zzs 1� iao 1 1 s A� � z FVNa �I�� KVA � � � � � AM � r ONE-LINE DIAGRAM SCHEMATIC SYMBOLS CIRCUIT BREAKER 225 PRAME SIZE (AMPERES) 100 = TRIP SETTING (AMPERES) KNIFE SWITCH OR DISCONNECT SWITCH PUSE (AMPERAGE SHOWN� PUSED KNIFE SWITCH 3 PHASE MOTOR SiARiER - NUMBER INDICATES NEMA SIZE #2 LEiTERS INDICATES SrARrER iYPE - FVNR=FULL VOLTAGE NON-REVERSING CONTROL TRANSFORMER POWER TRANSFORMER (KVA SHOWN) AUTOMATIC TRANSFER SWITCH POTENTIAL VOLTAGE iRANSFORMER CURRENT TRANSPoRMER THERMAL OVERLOAD (QL) LIGHTNING ARRESTER AMMEiER VOLTMETER cRouNo coNNEcrioN SERVICE and EQUIPMENT 0 TRANSFORMER, PAD MOUNTED ❑T TRANSFORMER, DRY TYPE (KVA SHOWN) G PANELBOARD ��P LIGHTWG CONTROL PANEL ❑� DISCONNECT SWITCH � COMBINATION STARTER � MAGNETIC STARTER g UTILITY METER cr O CURRENT TRANSFORMER CABINET � GENERATOR �� TELEPHONE TERMINAL BOARD ❑� AUTOMATIC TRANSFER SWITCH SOUND end SIGNAL Qs RECESSED CEILING SPEAKER 0 VOWME CONTROL p�a P.n. HORN IJ BUZZER �g DOOR BELL � DOOR CHIME e TELEVISION ANTENNA OUTLET �u MICROPHONE OUTLET �c WTERCOM OUTLET 4 NURSE CALL PULL STATION � NURSE CALL DOME LIGHT DOOR CONTACT 0 KEY PAD 0 CARD READER � CAMERA MECHANICAL �P MOTOR AND CONNECTION, HP SHOWN � CEILING TYPE FAN � PADDLE TYPE FAN � WALL iYPE FAN �� PIPE HEAT TRACING �� UNIi HEAiER � ELECTRIC BASEBOARD HEATER � ELECiRIC CEILING HEATER wH ELECiRIC WATER HEATER CONTROL QQ THERMOSTAT (LINE VOLTAGE UNO.) Q HUMIDISTAT (LWE VOLTAGE UNO.� PC PHOTOCELL Tc TIME CLOCK Q PUSHBUTTON STATION ❑c LIGHTING CONTACTOR SCHEDULE OF STANDARD MOUNTING HEIGHTS FOR ROUGH-IN OF ELECTRICAL DEVICES A. GENERALLY MOUNTING HEIGHTS OF DEVICES ARE TO BE AS FOLLOWS: (HEIGHTS GNEN ARE TO CENTER OF DEVICE BOX) (n.F.F. = naovE FiNisHEo F�ooR) (e.F.c = eE�ow FiwsHEo cEwNc) 1. RECEPTACLES, GENERAL +1'-6" AEP. 2 WALL SWITCHES, GENERAL +46" AF.F. 3. RECEPTACLES OVER WORKBENCHES, iABLES, ETC.: +4'-7' A.EP. 4. TELEPHONE OUTLETS OVER WORKBENCHES, TABLES, ETC.: +4'-2" A.F.F. 5. TELEPHONE OUTLEiS: +1'-6" AEF. (�ESK TYPE� 6. WALL TELEPHONE OUTLETS: +5'-0" AF.P. 7. WALL PUSHBUTTONS: +4'-0" A.F.F. 8. MOTOR CONTROLLERS: +4'-0" A.F.P. 9. DISCONNECT SWITCHES: +5'-0" AEP. 1Q FIRE ALARM PULL SiAiIONS: +4'-0" AF.F. 1L FIRE ALARM HORNS, BELLS, GONGS: +80" A.EF. OR 17' B.P.C. 12 THERMOSTATS: +4'-6" 13. RECEPTACLES/DEVICES MOUNTED ABOVE COUNTERiOP BACKSPLASH: +7'(MIN.J 14. RECEPTACLES�DEVICES MOUNTED ABOVE RADIANT HEATERS: +6"(MIN.� 15. WALL MOUNiED SPEAKERS: +8'-0" i6. CARD READER +3'-6" A.F.F. 17. EMERGENCY LIGHTING UNITS: (OFRCE) +7'-0"A.F.F. OR 12" B.F.C. (wnREHousE) +iz'-o" aF.F. 18. WALL MOUNTED, STAIRWELL LANDING, LIGHT FlXTURES: +7'-0" AF.F. 19. WALL MOUNTED SPEAKERS: +8'-0" A.F.F. OR 17' B.F.C. B. EXCEPTIONS TO REQUIREMENTS OF SCHEDULE: 1. AT JUNCiION OF DIFPERENT MAiERIALS IN WALL RNISHES. 2. WHERE OUTLETS WOULD OCCUR IN MOLDINGS, BREAK IN WALL SURFACE, OR UNSUITABLE LOCATION IN TILE, WOOD OR SIMILAR FlNISH. 3. WHERE OUTLETS WOULD CONFLICT WITH LOCATIONS OF WALL MOUNTED EQUIPMENT, SUCH AS RADIATORS, CONVECTORS, UNIT HEATERS, ETC. 4. AS NOTED OR INDICATED OTHERWISE ON DRAWINGS OR IN SPECIFlCATIONS. RELEASED FOR CONSTRl1CTI0N Su6jec��o compliance with allregula�ions of Sla�e antl Local Codes City of Carmel � ,�,,,�,�:,��ti�a � DATE: OIIZZIZO G SCHEDULE NOTES: 1. MOUNTING HEIGHTS ARE ABOVE FINISHED FLOOR TO CENTER OP OUTLET (DEVICE) BOX, UNLESS OTHERWISE NOTED OR INDICATED ON THE DRAWINGS OR SPECIRCAiIONS BY SPEQFlC NOTES OR oErni�s. 2. REPER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL WFORMATION ON DEVICE/OUTLET BOX INSTALLATION REQUIREMENiS. 3. GENERAL REQUIREMENTS POR OUTLET BOX INSTALLATION IN CONCRETE BLOCK OR TILE WALLS: A. IT IS INTENDED THAT OUTLET BOXES SHALL BE SET ON TOP oF n e�ocK (n�E) couRSE eE�ow, wirH rHE our�ET sPncE curiNto rHE aottoM oF tHE e�ocK (n�E) couRSE ABOVE. B. OUTLETS SHALL BE INSTALLED IN NEAREST BLOCK (TILE) COURSE TO THE SCHEDULED MOUNTING HEIGHT. 4. SPECIAL PURPOSE DEVICES (THOSE SERVING: COMMERCIAL KITCHEN EQUIPMENT, ELECTRIC WATER COOLERS, APPLIANCES, ETC.) SHALL BE IN AGREEMENT WITH APPROVED SHOP DRAWINGS. 5. TOGGLE TYPE SWITCHES, LIGHT SWIiCHES AN� MANUAL MOTOR SiARTERS, MOUNTED ABOVE BACKSPLASH OF COUNiERTOPS SHALL BE MOUNTED AT SAME HEIGHT AS RECEPTACLES. 6. COORDINATE DEVICE MOUNTING HEIGHTS WITH ARCHITECTURAL CASEWORK SHOP DRAWINGS. � GENERAL NOTES APPLY TO ALL ELECTRICAL SHEETS 1. ALL MATERIAL AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE 11. VERIFY HEIGHT AND LOCATION OF OUTLETS BEHIND WATER COOLERS CODES, SPEQFlCATIONS, LOCAL ORDINANCES AND INDUSTRY WITH OTHER TRADES, SO THAT OURETS ARE CONCEALED. srnNonRos. 12. REFER TO ARCHITECTURAL PLANS FOR DETAILS AND NOTES CONCERNING 2 NATIONAL ELECTRICAL CODE (NEC) AND INDUSTRY MSTALLATION ITEMS INVOLVING ELECTRICAL WORK. STANDARDS SHALL BE CONSIDERED MINIMUM STANDARDS. 13. REFER i0 ARCHITECTURAL RERECTED CEILING PLAN FOR CEILING 3. ALL CONOUITS AND BOXES SHALL BE PROPERLY SUPPORTED. TWES AN� FlXTURE LOCATIONS. ANY CONFLICTS BETWEEN ELECTRICAL PLANS AND REFLECTED CEILING PLANS SHALL BE 4. ALL GRS OR IMC CONDUITS ENTERING BOXES OR ENCLOSURES WITHOUT REPORTED AND RESOLVE� PRIOR TO ROUGH-IN. HUBS SHALL BE EQUIPPED WITH BUSHINGS AND SHALL HAVE LOCKNUTS INSIDE AND OUT OF ENCLOSURE. 14. REFER TO ARCHITECTURAL PLANS FOR FlNAL DOOR SWING AND LIGHT SWITCH LOCATIONS. ANY CONFLICT BETWEEN ELECTRICAL PLANS AND 5. ALL NECESSARY HANGERS ANO/OR MOUNiING ACCESSORIES FOR ARCHIiECil1RAL PLANS SHALL BE REPORiE� ANO RESOLVE� PRIOR i0 LIGHTING FlXTURES SHALL BE SUPPLIED BY E.G ROUGH-IN. 6. VERIFY ALL DIMENSIONS FROM ARCHITECTURAL PLANS. 15. REFER TO ARCHITECTl1RAL PLANS FOR ELEVATIONS OF CASEWORK AND/OR BUILT-IN SHELVING UNITS TO COORDINATE OUTLET 7. DIMENSIONS SHOWN ON OUTLET BOXES SHALL BE FROM THE FlNISHED ELEVATIONS. ANY CONFLICT BETWEEN ELECTRICAL PLANS AND FLOOR i0 iHE CENiER OF iHE BO%. ARCHIiECiURAL PLANS SHALL BE REPORiE� ANO RESOLVEO PRIOR i0 ROl1GH-IN. 8. COORDINATE LOCATION OF LIGHTS IN ROOMS CONTAINING EXPOSED DUCTWORK AND PIPING BY OTHER TRADES. 16. ALL FEEDERS AND BRANCH CIRCUITS RAN UNDERGROUND IN PVC CONDUIT SHALL INCLU�E A GROUND CONDUCiOR. 9. VERIFY ELECTRICAL CHARACTERISTICS AND ROUGH-IN REQUIREMENTS FOR ALL WUIPMENT FURNISHED BY OTHERS AND CONNECTED BY EC. 17. ALL DISCONNECT SWITCHES LOCATED OUTDOORS SHALL BE NEMA 3R (U.N.o.) 10. COORDINATE LOCATION OF MOTOR STARTERS, DISWNNECTS, PANELBOAROS, ETC. IN ROOMS CONTAINING EXPOSED DUCTWORK 18. ALL DISCONNECT SWITCHES LOCATED INOOORS SHALL BE NEMA 1 AND PIPING BV OTHER TRADES (U.N.O.J 19. ALL DISCONNECT SWITCHES LOCATED IN CORROSIVE ATMOSPHERES SHALL BE NEMA 4X (U.N.O.) ELECTRICAL ABBREVIATIONS A AMPERE(S) GALV GALVANIZED NEMA NATIONAL ELECTRICAL AC ALTERNATING CURRENT GF GROUND FAULT MANUFACTURERS ASSOCIATION AFP ABOVE FlNISHED FLOOR GR GROUND FAULT INTERRUPTER NEC NATIONAL ELECTRICAL CODE AL ALUMINUM GFP GROUND FAULT PROTECTION NF NON-FUSEO AMP AMPERE(S) GND GROUND NTS NOT TO SCALE ATS AUTOMATIC TRANSFER SWITCH HH HANDHOLE OL OVERLOAD BLDG BUIL�ING HID HIGH INTENSITY DISCHARGE 2P TWO POLE BKR BREAKER HOA HAND-0FF-AUTOMATIC PB PUSHBUTTON C CONDUIT HOR HAND-OFF-REMOTE PVC POLYVINYL CHLORIDE 2/C TWO CONDUCTOR (TYP) HOAR HAN�-0FF-AUTO-REMOTE RGS RIGID GALVANIZED STEEL CB CIRCUIT BREAKER HP HORSEPOWER SP SINGLE POLE CKi CIRCUIi HPS HIGH PRESSURE SODIUM SPDT SINGLE POLE DOUBLE THROW CPT CONTROL POWER TRANSFORMER IMC INTERMEDIATE METAL CONDUIT SPEC SPECIPICATION CPU COMPUTER JUNCTION BOX SPST SINGLE POLE SINGLE THROW CR CONTROL RELAY KV KILO VOLTS STR STARTER CT CONTROL TRANSFORMER KVA KILO VOLTS-AMPS SW SWITCH CU COPPER KVAR KILOVAR TTB TELEPHONE TERMINAL BOARD DISC. DISCONNECT LA LIGHTNING ARRESTOR TYP TYPICAL DT DUST TIGHT LiG LIGHiING UNO UNLESS NOTED OTHERWISE LOR LOCAL-0FF-REMOiE DWG DRAWING UL UNDERWRITERS LABORAi0RIE5 EP EXHAUST FAN MS MAGNETIC MOTOR STARTER COIL MAX MAXIMUM V VOLiS ELEV ELEVATION VFD VARIABLE FREOUENCY DRNE MCC MOTOR CONTROL CENTER EM EMERGENCY VS VOLTMEiER SWITCH EQUIP EQUIPMENi M� MOTORIZED �AMPER y� WIRE OR WATT EWC ELECTRIC WAiER COOLER MFR MANUPACTURER y�� WITH MH MANHOLE EP EXPLOSION PROOF W�0 WITHOUT FMC FLEHIBLE METALLIC CONDUIT MIN MINIMUM yyp WEATHERPROOF PVNR FULL-VOLTAGE NON-REVERSING N NEUTRAL %FMR TRANSPORMER PVR FULL-VOLiAGE REVERSING N/A NOi APPLICABLE HFR TRANSPER GROUND 0 PHASE D. AMERICANS WITH DISABILITIES ACT (ADA) NOTES: (PACILITIES COMPLIANCE WORKBOOK) CHAPTER 11 OF THE 2008 INDIANA BUILDING CODE - INDIANA ACCESSIBILITY CHAPTER 1. OPERAiING CONiROLS; INCLU�ING BUi NOi LIMIiE� i0 RECEPiACLES, SWIiCHES, WALL MOUNTED TELEPHONES, ETG.. A. MOUNTING HEIGHTS ARE TO THE HIGHEST OPERABLE PART OF THE CONTROL AND SHALL BE PLACED WITHIN AT LEAST ONE OF THE REACH RANGES SPECIFlEO IN ARTICLE 0.25 AND 426 OF CHAPTER 11 OF THE INDIANA BUILOING CODE - INDIANA ACCESSIBILIN CHAPTER (1) MOUNiING HEIGHTS OF THE ABOVE MENiIONED CONiROLS ARE i0 BE CONSIDERED FROM TWO (2J VANTAGE POINTS AS FOLLOWS; a FORWAR� ftEACH - IF THE CLEAR FLOOR SPACE ONLY ALLOWS FORWAR� APPROACH TO AN OBJECT, BY A PERSON IN A WHEELCHAIR, THE MAXIMUM HIGH FORWARD REACH ALLOWED SHALL BE +48" AF.E AND THE MINIMUM LOW FORWARD REACH ALLOWEO SHALL BE +15' A.F.F. IF iHE FORWARD REACH IS OVER AN OBJECi, iHEN iHE MAXIMUM HIGH FORWARD REACH SHALL BE ADJUSTED ACCORDING TO ARTICLE 4.25 FIG. 5(b) OF CHAPTER 11 OF THE INDIANA BUILDING CODE - INDIANA ACCESSIBILITV CHAPTER. b. SIDE REACH - IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH BY A PERSON IN A WHEELCHAIR, THE MAXIMUM HIGH SIDE REACH ALLOWED SHALL BE +54" AEF. AN� iHE MINIMUM LOW REACH SHALL BE NO LESS iHAN +15" A.F.F. IF THE SIDE REACH IS OVER AN OBJECT, THEN THE MAXIMUM HIGH SIDE REACH SHALL BE ADJUSTED ACCOROING TO ARTICLE 426 FIG. 6(c) OF CHAPTER 11 OF THE INDIANA BUILDING CODE - INDIANA ACCESSIBILITY CHAPTER 2 IF CONTROLS, DISPENSERS, RECEPTACLES, OR OhiER EOUIPMENT ARE PROVIDED QN BATHROOMS, BAiHING FACILIilES, ANO SHOWER ROOMS), iHEN "Ai LEASi ONE OF EACH�� SHALL 6E ON AN ACCESSIBLE ROUTE AND SHALL COMPLY WITH ARTIQE 4.D OF THE FEDERAL REGISTER/VOL 58, N0. 144/FRIDAY JULY 26, 1991/RULES AND REGULATIONS. 3. ALARMS; ARiICLE 4.25 A. MOUNTING HEIGHTS OF VISUAL ALARMS SHALL BE PLACED AT +80" ABOVE THE HIGHEST FLOOR LEVEL WIiHIN iHE SPACE OR 6" BELOW iHE CEILING, WHICHEVER IS LOWER. ARiICLE 425.3 SUB ARTICLE (f). 4. PROTRUDING OBJECTS; ARTICLE 4.4 (WALL SCONCES, HAND DRYERS, ETC...) A. GENERAL OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN +27" AEF. AND +80" AF.E SHALL PROTRUDE NO MORE THAN FOUR (4) INCHES INTO WALKS, HALLS, CORRI�ORS, PASSAGEWAVS, OR A6LE5. PROiRU�ING OBJECIS SHALL N01 REDUCE THE CLEAR `MDTH OF AN ACCESSIBLE ROUTE OR MANEWERING SPACE. G F E � � � �' �o O o �� �o ��E 0 0 u "z� ■¢ �-o 1� awT ��o w YJ� / W' �n w 3 � ry J 3 r m � O � N C L 7 _v O � ; � O 0 N �O W � � � � �O �O � >`?"' No. �ov� •;\ soo2msa j�p A�es�.,, E„.•%� � �yn�� Na 2 ,,.. s�a�>� e`' .,a� �� � � � � O ` � W � � � .� � � � � U .� � � � � d � c U • - `° � � � m � c m Q � � � N � � � �o � � E� L O N v � � �� c `o m � � �� L O � � � O N N � � � E � � Q =� Qlssuances: � � Proj. No.: -- Date: 01 /1 S/19 Sheet Name: STANDARD SYMBOL LEGEND E101