HomeMy WebLinkAboutEP-001-ELECTRICAL-LEGEND,-GENERAL-NOTES,-AND-ABBREVIATIONS-Rev.1� ro K U w J W N � @ N � C O rn a r ro � E � � U � � 0 a a w � , z 3 � � 7 PURPOSE RECEPTACLE. REFER TO FLOOR PLANS FOR NEMA � GENERAL LIGHTING/POWER NOTES L LIGHTFIXTURESDESIGNATEDAS"NIGHTLIGHTS"SHALLBEONUNSWITCHEDCIRCUIT,UNLESS NOTED. 2 EXIT LIGHTS SHALL BE ON UNSW ITCHED CIRCUIT, UNLESS NOTED. 3. ALL RECESSED DOWNLIGHTS MOUNTED W GRID CEILWG SHALL BE CENTERED IN CEILWG TILE, UNLESSNOTED. 4. IN ALL MECHANICAL ROOMS, COORDINATE EXACT LOCATION OF LIGHT FlXTURES WITH HVAC DUCTWORK. S CONDUCTORS FOR BRANCH CIRCUITRV ARE #12 AWG MINIMUM, UNLESS NOTED. DERATE PER CODE WHERE CIRCUITSARE COMBWED. 6. ALL HOMERUN CONDUCTORS BACK TO PANEL SHALL BE #10AWG MINIMUM, UNLESS NOTED. PROVIDE AGREEN GROUND CONDUCTOR INALL BRANCH CIRCUITRV. DERATE PER CODE WHERE CIRCUITS ARE COMBINED. 1. WHERE TERMINATED IN J-BOX, ALL SPARE CIRCUITRV SHALL BE LABELED W ITH PANEL AND CIRCUIT NUMBER. 8. COORDINATEWITHMECHANICALCONTRACTORANDPROVIDEALLNECESSARYAUXILIARY CONTACTS, RELAV, ETC. IN MOTOR STARTERS FOR REpUIRED CONTROLOF MECHANICAL E�UIPMENT. 9. ALL HOME RUN W IRING SHALL BE INSTALLED IN EMT OR RGS CONDUIT, UNLESS NOTED. 10. ALLUNDERGROUNDPVCCONDUITSSHALLHAVERIGIDGALVANIZEDSTEELELBOWS. 11. ALL LIGHT FlXTURES SHALL BE SEISMICALLV BRACED WITH AN INDEPENDENT WIRE (CEILWG GRID TVPE W IRE) FROM TW O OPPOSITE CORNERS TO STRUCTURAL CEILING OR BAR JOIST. 12. DONOTSUPPORTCONDUITOFFOFCEILWGGRID,CEILWGGRIDSUPPORTS,MECHANICAL SUPPORTS,ORANYOTHERTRADPS SUPPORTS.INSTALLCONDUITSANDBOXESONSEPARATE SUPPORTS FROM BAR JOIST OR STRUCTURE. 13. DO NOT SUPPORT FROM METAL ROOF DECK. PROVIDE SUPPORT FROM CONCRETE SIABS, BAR JOIST, STRUCTURAL BEAMS, COWMNS OR UNISTRUT BETWEEN STRUCTURAL ELEMENTS. 14. ALL SINGLE PHASE CIRCUITS SHALL HAVE A SEPARATE DEDICATED NEUTRAL CONDUCTOR FOR EACH CIRCUIT. SHARING OF NEUTRALCONDUCTOR IS NOT PERMITTED. 15. PROVIDE 4" HIGH, SMOOTH FINISH CONCRETE HOUSEKEEPING PADS UNDER ALLTRANSFORMERS (45KVA AND LARGER) AND MAIN DISTRIBUTION SW ITCHBOARDS. PAD SHALL BE 4" LARGER THAN TRANSFORMER AND SW ITCHBOARD W EACH DIRECTION. USE 3000 PSIG, 28 DAV COMPRESSNE STRENGTHCONCRETE.ROUNDALLEDGESANDCORNERSOFCONCRETEPAD. GENERAL PROJECT NOTES 1. WORK SHALL BE DONE IN ACCORDANCE W ITH LOCAL, STATE OF INDIANA, 2014 NEC AND NATIONALCODES,RECOMMENDATIONS,REGULATIONS,ANDREpUIREMENTS. 2 CONTRACTORSSHALLVISITPROJECTSITEPRIORTOBIDDINGTOASCERTAINAND BECOM E FAM ILIAR W ITH EXISTING CONDITIONS AS THEV PERTAIN TO THE SCOPE OF WORK. CONTRACTOR SHALL VERIFV EXACT LOCATION AND SIZES OF ELECTRICAL EpUIPMENTAND ALL OTHER APPURTENANCES ASSOCIATED W ITH THE WORK. 3. COORDINATE AND UTILITI' SHUT DOWNS, (ELECTRIC AND TELEPHONE) WITH THE OW NER AND PROVIDE NOTICE NOT LESS THAN ]2 HOURS IN ADVANCE. 4. COORDINATE ELECTRICAL RE�UIREMENTS FOR NEW OR WORK WITH THE PLUMBWG AND MECHANICAL CONTRACTORS. VERIFY VOLTAGE, PHASE AND ACCESSORY REpUIREMENTS, SUCH AS MOTOR STARTERSAND DISCONNECTS. 5. OPENINGS IN NEW WALLSAND FLOORS SHALL BE PLANNED AND COORDINATED WITH GENERAL CONTRACTOR FOR THE INSTALLATION OF APPROPRIATE SLEEVES. 6. ALLCONDUITSHALLBE3l4"MINIMUMU.N.O. �. CONDUITSHALLBECONCEALEDINCEILWGORWALLSWHEREVERPOSSIBLE. 8. ALL UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC UNLESS NOTED OTHER W ISE. 9. ALLBRANCHCIRCUITSANDFEEDERSSHALLCONTAINAGREENINSULATEDGROUND CONDUCTOR. GROUNDWG BV MEANS OF RACEWAV IS NOT PERMITTED. 10. REFERTOMECHANICAL,PLUMBING,ANDARCHITECTURALPLANSFOREXACT LOCATION OF E�UIPMENT. 11. COORDINATE LOCATIONS OF LIGHTING FIXTURES IN MECHANICAIJELECTRICAL ROOMS W ITH E�UIPMENT, PIPWG AND DUCTWORK. 12 CONTRACTOR SHALL COORDINATE EXACT HEIGHT OF DEVICES DESIGNED AS OVER COUNTER WITH CASE WORKAND FURNITURE DRAW WGS. 13. VERIFV CEILING TYPES PER THEARCHITECTURAL REFLECTED CEILING PLAN. PROVIDE APPROPRIATE TYPE FlXTURE, LAV-W FOR GRIq FLANGE FOR DRVWALL, ETC. 14. NO MORE THAN 3 PHASE CONDUCTORS SHALL BE INSTALLED IN ANV ONE CIRCUIT, UNLESS NOTED OTHER W ISE EACH BRANCH CIRCUIT SHALL CONTAIN THEIR OW N NEUTRALCONDUCTOR.NOSHAREDNEUTRALS. iS FURNISHALLELECTRICALACCESSFLOORSTOGENERALCONTRACTORFORHIS INSTALLATION. REFER TO SPECIFICATIONS FOR ACCESS DOOR REpUIREMENTS. i6. CONTRACTORSHALLPROVIDEALLFlRESTOPPWGFORCONDUITORCABLETRAV PENETRATIONS THAT PENETRATE ACOUSTICAL RATED OR SMOKE AND FIRE RATED ASSEM BLIES. SEE ARCHITECTURAL DRAW INGS FOR LOCATIONS OF ALL RATED ASSEMBLIES. ALL RATED PENETRATIONS SHALL BE FlRESTOPPED TOORIGINAL ASSEMBLY RATING. ALL NON-RATED FLOOR PENETRATIONS SHALL BE SEALED WATER TIGHT W ITH A FLEXIBLE SEALANT. 1]. BRANCHCIRCUITWIRINGCHARTTOBEUTILIZEDASGUIDELINEFORVOLTAGEDROP COMPENSATION, INCREASE CONDUIT SIZING PER W IRE SIZE (APPLIES TO ALL SHEETS) A 20A-120 VOLTCIRCUITS a. #12 W IRE - �5 LENGTH MAX. -#12 GRD. b. #10 W IRE - 12S LENGTH MAX. -#8 GRD. c. #8 W IRE - 200' LENGTH MAX. -#8 GRD. tl. k6 W IRE - 300' LENGTH MAX. -#6 GRD. 18. PROVIDEALLPULLBOXES,INACCESSIBLEAREA,THATEXCEEDNECNUMBEROF BENDS OR LENGTH W FEEDER AND BRANCH CIRCUITS. INSTALL BOXES WHERE REpUIRED PER CODE. 19. ALLWIRWGDEVICESSHALLBEOFHEAVVDUTYCOMMERCIALGRADECONSTRUCTION. REFER TO ARCMTECNRAL SHEETS AND CODE SHEET FOR ALL FIRERATED PARTITION LOCATIONS AND RATINGS. 20. CONTRACTOR IS RESPONSIBLE FOR ALLCOREDRILLS REpUIRED FOR INSTALLATION OF ELECTRICAL WORK. 21. VERIFYTHELOCATIONOFALLUTILITIESPRIORTOEXCAVATION,TRENCHING,OR DRILLING. 22. ALLEXPOSEDMETALCONDUITSARETOBEPAWTEDTOMATCHTHEADJACENT SURFACE. COORDINATION OF PAINTING OF CONDUIT IS TO BE BV THE ELECTRICAL CONTRACTOR, WITH PAINTWG BV OTHERS. 23. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDWG ALL RE�UIRED JUNCTION BOXES, PULL BOXES. ETC FOR A COMPLETE INSTALLATION PER THE N.EC. AND LOCAL CODES. ALL CONDUCTORS SHALL BE RATED FOR 90 DEGREE CELSIUS. 24. COORDINATE WORK WITH OTHER TRADES. COORDINATION OR SCHEDULWG SHALL BE RESPONSIBILITV OF THE INVOLVED CONTRACTORS. 2S ALLLOWVOLTAGECABLWGINSTALLEDINSPACESWITHOUTALAV-INORWITHAHARD CEILING SHALL BE INSTALLED IN CONDUITAND BOXES. 26. ALLELECTRICALROOMSARESHOWNWITHE�UIPMENTDRAWNTOSCALEAND ARRANGED TO ENSURE FlTAND CODE REpUIRED CLEARANCES. EpUIPMENTSHALL BE INSTALLED IN THE LOCATIONS SHOW N, UNLESS W RITTEN APPROVAL IS GIVEN BV THE ENG W EER, BASED UPON 1/4 SCALE DRAW WGS SUBMITTED BV THE CONTRACTOR FOR REVIEW ANDAPPROVAL. � ABBREVIATIONS A AMPS KW KILOWATTS AFF ABOVE FINISHED FLOOR LGTG LIGHTING AFG ABOVE FINISHED GRADE MECH MECHANICAL BKR BREAKER NIC NOTINCONTRACT � CONDUIT NL NIGHT LIGHT CATV CABLETELEVISION NTS NOTTOSCALE CUH CABWETUNITHEATER PVC POLYVINYLCHLORIDE CKT CIRCUIT P PHASE (POLE) Cu COPPER TTB TELEPHONE TERMINALBOX E EXISTING TYP TYPICAL EF EXHAUSTFAN UON UNLESSOTHERWISENOTED ELEC ELECTRICAL UV UNITVENTILATOR EM EMERGENCV V VOLTS EMT EMERGENCVMETALLICTUBING VAV VARIABLEAIRVOWME FCU FAN COIL UNIT VIF VERIFY W FlELD G GROUND W WATTS GFI GROUND FAULT INTERRUPTER WC WATER COOLER GRC GALVANIZEDRIGIDCONDUIT WP WEATHERPROOF HP HORSEPOWER UH UNITHEATER � JUNCTIONBOX UNO UNLESSNOTEDOTHERWISE KVA KILOVOLTAMPERE ELECTRICAL LEGEND LIGHTING �A � A NL . .:, H � � a�3 Y4 �OS �P YD 1:d 1�1 � LIGHTING FIXTURE. REFER TO FIXTURE SCHEDULE LETTER INDICATES TVPE. EMERGENCY LIGHTING FIXTURE WITH EMERGENCYBALLAST. "NC' INDICATES NIGHT LIGHT CIRCUIT. FULL LUMEN OUTPUT MINIMUM 1400 LUMENS ON LAMP. LIGHTING FIXTURE LETTER INDICATESTVPE. EMERGENCV LIGHTING FIXTURE WITH EMERGENCV BALLAST.OR POWERED THROUGH INVERTER SVSTEM. CEIL W G MOUNTED EXIT SIGN. REFER TO FlXTURE SCHEDULE SHADED AREA DENOTES FACE OF UNIT. CONNECT TO LOCAL UNSWITCHED LIGHTING CIRCUIT. WALL MOUNTED EXIT SIGN. REFER TO FIXTURE SCHEDULE. SHADED AREA DENOTES FACE OF UNIT. CONNECT TO LOCAL UNSWITCHED LIGHTWGCIRCUIT. SWGLE POLE WALL SW ITCH. 120/2�� VOLT, 20 AMP. 44" AFF. THREE WAY WALL SW ITCH. 120/2��V, 20 AMP.44" AFF FOUR W AV WALL SW ITCH. 120/2]N, 20 AMP. 44" AFF OCCUPANCY SENSOR W ALL SW ITCH. 120/2��V, 20 AM P. 44" AFF S W GLE POLE WALL SW ITCH W ITH PILOT LIGHT. 120/2��V, 20 AMP. 44" AFF DIMMER SVSTEM CONTROL STATION. REFER TO DWG OCCUPANCVSENSOR. EXTERIOR LIGHT FIXNRE. ER - EXISTWG TO REMAIN. PLi - NEW FIXTURE. REFER TO FIXTURE SCHEDULE. POWER DUPLEX RECEPTAQE 120 VOLT, 20 AMP. 16" AFF UNO. DUPLEX RECEPTACLE MOUNTED AT 44" OR ABOVE BACKSPLASH. 120 VOLT, DOUBLE DUPLEX RECEPTACLE 120 VOLT, 20 AMP. 16" AFF UNO. 120 VOLT DOUBLE DUPLEX, 20 AMP RECEPTACLE MOUNTEo AT 44" AFF OR 4" (� DUPLEX RECEPTACLE W ITH GROUND FAULT PROTECTION. 120 VOLT, 20 AM P. TYWp 18"AFFUNO. GFl � WEATHERPROOF OUTLET BOX. �IG 120 VOLT DUPLEX, 20 AMP, ISOLATED GROUND RECEPTACLE. 120 VOLT DUPLEX , 20 AM P RECEPTACLE CEILING MOUNTED IN NV ��� POCKETfOUTLETFORPROJECTORREFERTOLVDRAWWGSFOR U FWSH FLOOR DUPLEXRECEPTACLE W FLOOR BOX. O PT POKE THRU FWSH FLOOR DEVICE WITH POWER, DATAAND NV. P-POWER � 120VOLTSWGLE20AMPRECEPTACLE. \/ � � P/P1 \L2�1 ' \ 0 W C}y �LV BAS � -ll� L��I IC� � �CTIONAL HP MOTOR STARTER W ITH THERMAL OVERLOADS. CTRICAL MOTOR. ICATES FINAL CONNECTION REpUIRED. dERUN TO PANELBOARD. NOTION INDICATES PANEL AND CIRCUIT ABER. (ALL CONDUCTORS SHALL BE#10 UNLESS NOTED OTHERWISE.) CTRICAL PANELBOARD. ICTION BOX. VOLT20AMP DUPLEX, GFI RECEPTACLE FOR ELECTRIC WATER COOLER. �RDINATE INSTALLATION WITH PLUMBWG CONTRACTOR. TFORM LIGHTING CONTROL PANEL. _DING AUTOMATION CONTROL PANEL. O ❑U 0 � O O SD FACP FAAP �I/ ❑F WPU � RPS ❑Z L KB SD L C � �^ rr OG • F •S /�\ � FIRE ALARM FIRE ALARM PULL STATION. 44" AFF. FIRE ALARM HORN/STROBE. 80" AFF. VALVE SUPERVISORV SW ITCH PROVIDED BV OTHERS. W ATERFLOW SW ITCH PROVIDED BV OTHERS. FlRE ALARM DUCT MOUNTED SMOKE DETECTOR. S= SUPPLY, R= RETURN - COORDINATE WITH DUCTWORK. MAKE SAMPLING TUBE FULL WIDTH OF DUCT W LENGTH. FIRE ALARM CEILWG MOUNTED SMOKE DETECTOR. FIRE ALARM CEILING MOUNTED HEAT DETECTOR. SMOKE DAMPER. PROVIDE SMOKE DETECTOR FOR DAMPER OPERATION AND 120 VOLTPOWERCONNECTIONASSHOWNONTHEPOWERDRAWINGS.COORDINATE ALL CONNECTIONS W ITH MECHANICAL CONTRACTOR. CONNECT TO ALARM SVSTEM. FIRE ALARM CONTROL PANEL. FlRE ALARM ANNUNCIATOR PANEL. FlRE ALARM STROBE 80" AFF. EXTERIOR FIRE ALARM BELL W P- W EATHERPROOF MAGNETIC DOOR HOLD OPEN. FIRE ALARM REMOTE POWER SUPPLV RRE ALARM MOMTOR MODULE FIRE ALARM PRESSURE SW ITCH. FIRE ALARM CONTROL RELAV MODULE. END OF THE LWE RESISTOR. KNOX BOX WITHALARM CONTACT. DUCT MOUNTED SMOKE DAMPER BV MECHANICAL CONTRACTOR. PROVIDE A DL MOUNTED SMOKE DETECTOR, W ITH RELAV BASE, MOUNTED W ITHIN 5'-0" OF THE DAMPER W ITH NO AIR OUTLETS OR INLETS BETW EEN THE DETECTOR AND THE DOOR ACCESS ELECTRIC DOOR STRIKE. DOOR SW ITCHICONTACT. KEV OR KEVCARD ACTIVATED SW ITCH IN TAM PER PROOF ENCLOSURE. W P - W EATHERPROOF. JUNCTION BOX HANDICAP DOOR ACCESS BUTTON IN FLUSH WALL BOX. GROUNDING GROUND ROD 3/4" DIA. x 10' LONG GROUND CABLE EXOTHERMIC W ELD CONNECTION TO REBAR ROD IN CONCRETE FOOTER. GROUND CABLE EXOTHERMIC WELD CONNECTION TO BUILDWG STEEL. UNDERGROUNDCOPPERCABLE. LIGHTNING PROTECTION LIGHTNWG PROTECTION CABLE. LIGHTNING PROTECTIONAIRTERMINAL. GENERAL DETAIL# DETAILREFERENCETAG DRAW ING # REFER TO DETAIL SHEETS KEVNOTE FOR DRAW WG DETAIL REFERENCE TAG (SECTION) RGROl1ND HIGH VOLTAGE OR SECONDARV SERVICE FEED. 1 DOOR OR CABLETRAV CONFlGURATION DETAIL REFERENCE TAG LETTER NEXT TO TAG REFERS TO SPECIFIC DOOR OR CABLETRAV iV�ISCONNECTSWITCH (NON-FUSED). E402 B LAVOUT. CONFlGURATION INDICATED IN DETAIL. iV DISCONNECT SW ITCH (FUSED). MECHANICAL EpUI PMENT TAG. REFER TO EpUIPM ENT DATA EF-1 SCHEDULE. 31NATION MOTOR STARTER/DISCONNECT. HOA SWITCH AT UNIT (FUSIBLE).OR (CIRCUIT BREAKER FOR ELEVATOR). DATA AND COMMUNICATION v DATAICOMMUNICATIONOUTLET.TWOPORTSREFERTODETAILFOR MOUNTWG RWUIREMENTS. �W WALLPHONE54"AFF. � DATA WTLET. i6" AFF. �q DATNCOMMUNICATION.FOURPORTDATA,i6"AFF. �6 DATNCOMMUNICATION.SIXPORTDATA,i6"AFF. � CABLE TRAV ABOVE CEILWG. WIRELESSACCESSCONNECTIONPOWTWITH CEILINGMOUNTEDCISCO �Wqp WIRELESSDEVICE. -COM- UNDERGROUNDCOMMUNICATIONDUCT. RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �i `��¢m�' lamn�Ml1 � DATE: O1IZZ/ZO 02/22/18 - GARAGE PERMIT �J� � WOOLPEQT R0.CXREttU0.E�H61HEE0.1H616E09PRTIRL 76351nteractive Way Suite 100 � Indianapolis, IN 462%a 317.299.7500 FAX: 317.291.5805 �y �� ��. ty �j ' ., � v1 I�i�� �.:NFC,ISTFj�F' ���Q �.:�' 6Gi;sp:ii(: �'�' ._J �, ��,,., .�. ��r."'.!ArDL� � �^ i^` W � � O W �^` W � � U � J•� J � � K y--� � U = � � � � c m Q O � � � � � � � � o` > N M V/ � O � � N� � U m � Q! `o `m c o � � � o� L L � - N N � U � C� _ � Proj. No.: 074904 Date: 03/OS/1 S A Sheet Name: ELECTRICAL LEGEND, GENERALNOTES,AND ABBREVIATIONS E�-001 `�.Issuances: