Loading...
HomeMy WebLinkAboutG6-001-COVER-SHEET-Rev.1, 2 3 5 4 � 9 The Proscenium Development AGORA OFFICE BUILDING: ISSUED FOR CONSTRUCTION July 1, 2019 PROJECT TEAM � � � W OOLPERT 1203 Walnut Street, Second Roor Cincinnati, OH 45202 W O O L P E R T Tel: 513.272.8300 oesicN cEosPnric� irv�a<sraucroue F3%:937.461.0743 www.woolpert.com LOCATION MAP irocnF.m � Ymimsm.,� � ' snrone.a � � � CarmJ ..� ._-�PROJECT finFer. i.e, � � ,,:,��, — SITE � - � .. � . m �_ nm.�im� C� � _ P ��� � m tin..ii�IL .., ,. i._ � `- [ m � ks creek aa � . .�. � I , rv�... _._ , cowerves� � � ii .. _ 4.ownsEmg�- � H ky110V1e � � � sP��sNnl �wrence n [�c,e, �.� ��; � � _ -� v �,..�w«Y `v V/e en PaM od�. , ; , � Indiao _. �,�-. o" ' r.�� .._ apolis . ,. — � �i � eee<M1cmve m i+ .,,�. �i.«.���.,�� . . ,.,� - ., - O nom�.,oi�� � -a � _ so��npan . 9 , �.�..,,.. ..i VICINITY MAP 3 wr ^ = s�os�o��o, � v. k. �_ .�ui .i.ip ���_�!-_�.. �� PROJECT SITE a,�m���.��� ���v��,�.� �� �eem�i or na�se��. o�smv = z c,a�un���.o .M. PROJECT IMAGE — �34ki �j Kv . :-'> r� � = , - dl. � � , (. � � � T � `� r� ' �`� � i � ` � bf . ' i � � �.r y r� — - Yl�Y �ir�...ar . �. ¢� te � i�= a.. � ., 1/� . .. . . . ..�� AM��4AJ� � �e:��.„ . .,�iC!.�. � . �.. r , ,{ rir�.. ..�.d�ll4L_rrY�rYwrwrr�� -e..iV" --..J"�G..�....J�I�e� - -.. �t_- ,� '; � � ',� � , � j . ;� �,/,"� , _ � . . � � - . •� _ , 1 � � . � � �. �a � � ' I� '_ � � l � -L � � �` � i , �� � � � �� �F fi l � E� . � yI��$_����.�111 �„ p � i.� �. ' -l� � � �' � f V .a�'��E �t ,�^��Sii. ������� e.,. 7 N' w': � GENERAL NOTES A. CONTRACTOR SHALL VERIFVALL DIMENSIONSAND EXISTMG CONDITIONS IN THE RELD PRIOR TOORDERMG OR FABRICATION OF MATER WLS OR THE BEGINNING OF CONSTRUCTION. NOTIFV ARCHITECT AND OW NER REPRESENTATIVE OF ALL DISCREPANCIES. ALL WORK REQUIRING MEASURING TO BE DONE ACCORDING TO FIGURES ON DRAW MGS. DISCREPANCIES BETNEEN ACTUAL CONDITIONS AND DRAW MGS SHALL BE BROUGHT TO THEIMMEDIATEATTENTIONOFTHEARCHITECTANDOWNERREPRESENTATNE CONTRACTORTOSUBMIT SPECIFIC DISCREPANCV FOR ARCHITECT REVIEW, PRIOR TO COMMENCMG WRH THE WORK IN QUESTION. B. ALLWORKTOCONFORMTOLOCALCODES,ORDINANCESANDRE�UIREMENTS. C. THECONTRACTORSHALLARRANGEFORTHEPREMISESTOBEMAINTAINEDINANORDERLVMANNER,FREEOF DUSTANDDEBRIS,THROUGHOUTTHECOURSEOFTHEWORK. PROVIDEANDMAINTAINTEMPORARVBARRICADES AS RE�UIRED TO PROTECT THE PUBLIC AND OW NERS PERSONNEL DURMG CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANV DAMAGE TO THE EXISTING STRUCTURE OR EpUIPMENT. ANV SUCH DAMAGE SHALL BE REPAIRED AT TH E CONTRACTOR'S EXPENSE. D. CONTRACTOR SHALL PROVIDE DAILY OR MORE FRE�UENTGENERAL CLEAN UP IN COMPLIANCE WITH OWNER'S REpUIREMENTS OF AREAS W ITHIN THE LIMITS OF CONSTRUCTION, AND FINAL CLEAN UP AT CONCLUSION OF WORK. E CONTRACTORTOREVIEWOTHERDRAWINGSISSUEDFORTHISPROJECTFORADDRIONALMFORMATIONFROM OTHER TRADES TO COORDINATE THE REQUIRED SCOPE OF WORK. E DONOTSCALEFROMTHEDRAWINGS.WRITTENDIMENSIONSSHALLTAKEPRECEDENCE.THEOWNER'S REPRESENTATNE MUST BE NOTIFIED OF ANV CONRICTS IN DIMENSIONING. G. EXTERIOR DIMENSIONS ARE TO FACE OF BRICK VENEER OR FACE OF METAL STUD, BRICK VENEER, MASONRV OPENING, OR COWMN CENTERLINE UNLESS OTHERWISE NOTED. MTERIOR DIMENSIONSARE W FACE OF EXTERIOR STUq FACE OF MASONRV, FACE OF CONCRETE, CENTERLME OF COLUMNS, OR FACE OF INTERIOR STUD UNLESS OTHERW ISE NOTED. H. ALL MATERIAL$ FlMURESAND EQUIPMENT INDICATED M THE CONSTRUCTION DOCUMENTS SHALLBE NEW AND AS SPEGFIED, UNLESS IDENTIFIED OTHERWISE. I. ALL FLOORS ON EITHER SIDE OF A DOORWAY OR OPENING SHALL BE LEVELAND HAVE MAXIMUM ELEVATION DIFFERENCE OR THRESHOLD HEIGHT OF VY. J. DOOR OPENINGS NOT LOCATED BV DIMENSION SHALL BE 4" FROM THE FACE OF STUD TO FACE OF STUD OF DOOR FRAME JAMB UNLESS NOTED OTHERWISE. K. DOOR SIZES, STVLES, AND SPECIFICATIONS, ROUGH OPENING SIZESAND EXACT LOCATIONSTO BE CHECKED AND VERIFIED BV THE CONTRACTOR BEFORE ORDERING AND BEFORE CONSTRUCTION BEGINS. L ALL PENETRATIONS OF RRE RATED FLOORS, WALLS AND CEILINGS TO BE SEALED W ITH PROPER APPROVED MATERIALS TO THE FULL THICKNESS OF THE CONSTRUCTION ELEMENTS. M. FIRESTOPALLFLOORS,WALLSANDCEILINGSASREQUIREDBVAPPLICABLECODE. N. ALL WOOD BLOCKING IN EMERIOR WALLS TO BE MOISTURE RESISTANT TREATED IN ACCORDANCE W ITH SPECIFICATIONS. WHERE REQUIRED BV CODE ALL WOOD BLOCKING IN INTERIOR WALLSTO BE FIRE RETARDANT TREATED IN ACCORDANCE WITH SPECIFICATIONS. O. INSTALL SEALANT AT EXTERIOR SIDE OF ALL JOMTS, SEAMS, CONNECTIONS OR OPENINGS W HICH W W LD ALLOW WATERORAIRINFlLTRATIONEXCEPTASNOTEDOTHERWISE. SEALANTCOLORTOMATCHARCHITECT'SSAMPLE. COLOR REQUIRES ARC HITECT'S APPROVAL. P. PROVIDE RRE EXTINGUISHER COMPLVING WITH NFPA 10 AS INDICATED ON LIFE SAFETV DRAWINGS WITH MAX TRAVEL DISTANCE OF ]5'. Q. MASONRVCONTROLJOINTSARESHOWNFORREFERENCEONLV LOCATIONSOFCONTROLJOINTSSHALLBEPER THE NATIONAL BRICK INDUSTRV ASSOCIATION GUIDELMES. R. THE LOCATIONSOF EXISTING UTILITIES HAVE BEEN PREPARED FROM DOCUMEMS PROVIDED BVTHE OWNERAND MAYNOTREPRESENTTHEACTUALRELDCONDITIONS. CONTRACTORTOREVIEWALLOWNERDOCUMENTSAND BECOME FAMILWR WITH ALL EXISTING UTRRIES. THE CONTRACTOR HASTHE RESPONSIBILITV TO VERIFV LOCATIONS IN THE FIELD BV EMPLOVING FIELD UTILITV LOCATING SERVICES BEFORE CONSTRUCTION STARTS AND COORDINATE ALL NEW UTILITY LOCATIONS, CONNECTIONS AND PENETRATIONS. 5. THESUBCONTRACTORSHALLVERIFYANDCOORDINATE,WITHALLTRADES,THESRESANDLOCATIONSOFALL OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS, OR BASESAS WELLAS POWER, WATER,AND DRAIN INSTALLATIONS BEFORE PROCEEDMG WITH WORK. SUBCONTRACTOR SHALL PROVIDECOORDINATIONDRAWINGSFORPROPERPLACEMENTOFALLTRADES'WORK. ALLCONCERNS,SPACE LIMITATIONS OR STRUCTURAL CONFLICTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT, PRIOR TO COMMENCING W ITH THE W ORK IN DUESTION. T. IT IS THE SUBCONTRACTOR'S RESPONSIBILITV TO COORDINATE AND LOCATE ELECTRICAL, DATA, AND PHONE RECEPTAQES, 5 W ITCHE$ ETG TO AVOID CONFLICTS W ITH CASEW ORK, DOORS, AND OTHER TRADES. PROJECT INFORMATION SHEETINDEX L r,a-nn1 CovER FETY C;fi-(1(1� BUILDING CODE SUMMARY AND FIRST FLOOR LIFE SAFETY PLAN C;fi-003 SECOND, THIRD AND FOURTH FLOOR LIFE SAFETY PLAN C;R-(1(14 PARKING LEVEL LIFE SAFETY PLAN RAL GENERALNOTES �reaH� w�ree i i�ry SPECIAL INSPECTION CONT. FIRST FLOOR FRAMING PLAN FIRST FLOOR SLAB EDGE PLAN SECONO FLOOR FRAMING PLAN SLAB EDGE PLAN THIRD FLOOR FRAMING PLAN FOURTH FLOOR FRAMING PLAN ROOF FRAMING PLAN K��r ueerc eut;e r�Hry SNOW DRIFT AND WIND UPLIFT LOADING DIAGRAM RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel Y,:,,, w��:,,�zti„�.1 DATE: OIIZZIZO tlKACtU FKAMt tLtVAI IUNS BRACED FRAME DETAILS ENLARGED FRAMING PLANS FRAMING DETAILS rKHMINIi Ut IHILJ FRAMING DETAILS FRAMING DETAILS J I HIK Ut I HILJ STAIR DETAILS nfi-nn� ABBREVIATIONS, SYMBOLS AND GENERAL NOTES Afi-009 PARTITION NPES Afi-100 PARKING LEVEL ROOR PLAN Afi-101 FIRST FLOOR PLAN Afi-1(1� SECOND FLOOR PLAN Afi-103 THIRD FLOOR PLAN Ae,-10d FOURTH FLOOR PLAN Afi-1f7.�, ROOF PLAN Afi-110 PARKING LEVEL RERECTED CEILING PLAN Afi-� � � FIRST FLOOR REFLECTED CEILING PLAN Afi-11� SECOND FLOOR REFLECTED CEILING PLAN Afi-��� THIRD FLOOR REFLECTED CEILING PLAN Afi-114 FOURTH FLOOR REFLECTED CEILING PLAN Afi-1�(1 ENLARGED RESTROOM PLANS AND DETAILS Afi-13(1 ENLARGED PLAN DETAILS Ae,-131 ENLARGEO PLAN OETAILS Afi-13� ENLARGED PLAN DETAILS Afi-133 ENLARGED PLAN DETAILS Afi-9M EXTERIOR ELEVATIONS Afi-�fl� ENLARGED NORTH ELEVATION Afi-�n3 ENLARGED SOUTH ELEVATION Afi-904 ENLARGED EAST ELEVATION Afi-�(1.�, ENLARGED EAST ELEVATION Afi-�f)fi ENLARGED WEST ELEVATION Afi-9m ENLARGED WEST ELEVATION Afi-301 BUILDWGSECTIONS Afi-7f1� BUILDING SECTIONS Afi-303 WALL SECTIONS Afi-304 WALL SECTIONS PROJECT LOCATION: IMERSECTION OF CARM EL DRNE AND RANGELME ROAD - HAM ILTON COUNTV, INDIANA PROJECTNAME THEPROSCENIUMDEVELOPMENT-AGORAOFFICEBUILDING GOVERNMG BUILDMG CODE: SEE LIFE SAFETV SHEETS PROJECTTVPE COREANDSHELLCOMMERCIALBUILDING Afi-305 WALL SECTIONS Afi-30fi WALL SECTIONS Afi31 n ENLARGED STAIR AND ELEVATOR PLANS Afi-311 NORTH STAIR AND ELEVATOR SECTIONS Afi-71� SOUTH STAIR SECTIONS Afi-401 SECTION DETAILS Afi-4(1� SECTION DETAILS Afi-403 SECTION DETAILS Ae,-dOd SECTION �ETAILS Afidf7.�, SECTION DETAILS Afi-Sf)(1 DOOR SCHEDULE AND DETAILS nfi-sn� STOREFRONT ELEVATIONS Afi-.�,f» CURTAIN WALL ELEVATIONS COVER SHEET 1 ST FLOOR ZONE 1 2N0 FLOOR ZONE 2 3RD FLOOR ZONE 3 4TH FLOOR ZONE 4 STANDPIPE DETAILS P-100 PLUMBING - PARKING LEVEL P-101 PLUMBING - FIRST FLOOR P-109 PLUMBING - 2ND FLOOR P-�ns �PLUMBING-THIRDFLOOR P-104 PLUMBWG-FOURTHFLOOR P-1f15 PLUMBING - ROOF PLAN P-fi00 PWMBWG SCHEDULES & DETAILS July 1, 2019 - ISSUED FOR CONSTRUCTION 1 ST FLOOR HVAC PLAN 2ND FLOOR HVAC PLAN 3RD FLOOR HVAC PLAN 4TH FLOOR HVAC PLAN ROOF HVAC PLAN SCHEDULES F�m FIRST FLOOR ELECTRICAL PLAN F�f7� SECOND FLOOR ELECTRICAL PLAN F�n� THIRD FLOOR ELECTRICAL PLAN F�f74 FOURTH FLOOR ELECTRICAL PLAN F�(15 ROOF ELECTRICAL PLAN F501 ELECTRICAL RISER DIAGRAM SHEET TOTAL 94 ,._ ��S� + ♦ 1 V WQ�i3LRE C2T CXRECTVRE�H6ME611HpIpEWP]T]L 76351nteractive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 F E ��� C �:� � _ s � a o — 3 3 �o �o � .� � � � � �O �O � �� � � O W � 0 � � .� � � U�' � � � �� � � U = � � � m � _ L `° Q � o � � c� �� o �o L � �� � � p �� c `o m c o � � � o� � � �d � J � Q �� c . `�.Jssuances: Proi. No.: 077392 Date: 02I01119 A Sheet Name: COVER G6-001