HomeMy WebLinkAboutGN000.1LOT SPECIFIED PLAN INFORMATION
Customer Name
{\C256;* Market Home *, 6838-01400#5}
Address{\C256;12994 COPPER RUN BOULEVARD}{\Fsimplex|c0;\C256;CARMEL}{\C256;IN}{\C256;46074}
Community{\Fsimplex|c0;\C256;6838}{\C256;COPPER RUN}{\C256;6838-01400}{\C256;LOTNUM 123}
Plan Features{\C256;Elevation CT2S}
MUNICIPALITY
STRUCTURAL ENGINEER APPLICABLE CODES
MECHANICAL ENGINEER
BUILDING CODE ANALYSIS
DESIGN LOADS and CRITERIA
AREA CALCULATION (SQ. FT.)
\pxt12;{\H0.92593x;BUILDING CODE:\PPLUMBING CODE: \P\pql;MECHANICAL CODE:\PFUEL AND GAS CODE:\P\pq*;ENERGY CODE:\PELECTRICAL CODE:\P\pql;FIRE CODE:\P\pt14;\P\pq*,tz;}1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE REQUIRED DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. VERIFY WITH THE LOCAL BUILDING AGENCIES THE WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. THE ARCHITECT SHALL BE NOTIFIED IN WRITING OF ALL DISCREPANCIES.\P\pa0.25;2. THERE SHALL BE NO STRUCTURAL CHANGES WITHOUT WRITTEN CONSENT OF THE ENGINEER OF RECORD.{\H0.92593x; }
ZONING ORDINANCE: .\PUSE GROUP: .\PCONSTRUCTION CLASS: .\PHEIGHT & AREA: .\POTHER REQUIREMENTS: .\pxt20,28;LIVE LOADS:\P\pt2,r28; Sleeping ___ PSF\P Non-Sleeping ___ PSF\P Ext. Decks & Stairs ___ PSF\P\ptr28;DEAD LOAD: ___ PSF\P\pt2,r27; Guard Rail & Handrail ___ LB \P\pt2,r28; Guard Infill Components ___ PSF\P\ptr28;WIND SPEED: ___ MPH\PROOF LIVE LOAD: ___ PSF\PSNOW LOAD: ___ PSF\PLATERAL LOAD: ___ PCF
\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}
\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}
SHEET LIST TABLE
SHT DESCRIPTION
CC.01 Cover Sheet
CC.02 Notes - Schedules and Legends
CC.03 General Notes
A0.01 Foundation - Basement
A1.01 Finished Basement Floor Plan
A1.11 1st Floor Plan
A1.21 2nd Floor Plan
A2.01 Building Section
A2.02 Building Section
A2.03 Building Section
A3.01 Front Elevation
A3.02 Left Elevation
A3.03 Right Elevation
A3.04 Rear Elevation
A4.01 Roof Plan
U1.01 Finished Basement Utility Plan
U1.11 1st Floor Utility Plan
U1.21 2nd Floor Utility Plan
S-1.0 Structural Plan - Foundation Basement (IN Code)
S-2.0 Structural Plan - 1st Floor (IN Code)
S-3.0 Structural Plan - 2nd Floor (IN Code)LOT SPECIFIC OPTION SELECTIONSOpt Cabinets at LaundryOpt. Additional Cabinets at Pulte Planning CenterOpt. Base Cabinet at PPCBath 7 OptionOpt. Bedroom 618" Brick Wainscot - Sides and RearBuilt in Kitchen OptionOpt Coach Light - Location 1Opt Coach Light - Location 3Opt. Door at FlexElevation CT2SNo OptionFinished Basement OptionBasement FoundationTraditional Fireplace at Gathering Room3 Car Side Load GarageMasonry Wrap - Sides and RearOwner's Bath 5Shower at Bath 6Opt Sink at LaundryIndianaOpt Tray Ceiling at Owners SuiteOpt. Uncovered Patio at RearOpt Basement Window Well - Location 3
SQUARE FOOTAGE
TOTAL:CONDITIONED - LIVABLE SF
1st Floor
2nd Floor
Basement - Finished
1854 SF
1437 SF
1059 SF
4350 SF
TOTAL:CONDITIONED - NON-LIVABLE SF
Basement - Storage & Mech 681 SF
681 SF
TOTAL:UNCONDITIONED SF
3 Car Garage Side
Front Porch
Uncovered Rear Patio
631 SF
120 SF
140 SF
890 SF
5921 SF
COVER SHEETMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc.
PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:05/10/2019
PROJECT TYPESingle Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Woodside
2312.300Home for * Market Home *, 6838-01400#512994 Copper Run Boulevard, Carmel, IN 46074CC.01
01/22/20
William Hohlt