HomeMy WebLinkAboutC508 - PLAN & PROFILE (STORM) (V2)OHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUW WWFDC 6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD 6''SSD6''SSD6''SSD6''SSDR D RD RD RD RD R D R D R D NO PARK ING6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD 758 RIM=855.00 759 RIM=854.50 779 RIM=854.10 748 RIM=854.20 776 RIM=852.55 778 RIM=852.40 747 RIM=851.75 760 RIM=852.25 746 RIM=852.20 777 RIM=851.90 761 RIM=851.80 756 RIM=851.30 787RIM=851.50 757 RIM=851.30 61' OF 18" RCP@0.25%189' OF 24" RCP @0.25%95' OF 24" RCP@0.25%68' O F 1 2 " R C P @0.5 5 % 24' OF 15" RCP @0.85% 67' OF 18" RCP @1.05% 10' OF 12" RCP @1.52% 6 3 ' O F 1 2 " HDP E@2 . 7 0%60' OF 12" RCP@0.84%36' OF 15" R CP @0.63 %79' OF 18" RCP@0.47% 1 2 8 ' O F 1 2 " H D P E@1 . 9 9% 199' O F 8" H D P E @1.9 7 % 156' OF 8" HDPE @0.50% STRUCTURE 748-759, 758 STRUCTURE 756,747-748, 760 67' 1.05% 18" R C P STR. #758 MANHOLE, 4' DIA.; R-1772TC: 855.00INV. OUT 850.50 (15" RCP (SW)) 24' 0.85% 15" RCPSTR. #759 INLET AM; R-3405TC: 854.50INV. IN 850.30 (15" RCP (NE))INV. OUT 850.20 (18" RCP (SW))10 - YEAR HGL 10 - YEAR HGLSTR. #756 MH 4' DIA.; R-3010TC: 851.30INV. IN 846.52 (24" RCP (S))INV. IN 847.50 (12" RCP (W))INV. IN 847.15 (12" RCP (E))INV. OUT 846.42 (24" RCP (N))STR. #747 MH 4' DIA.; R-3010TC: 851.75INV. IN 846.86 (24" RCP (S))INV. OUT 846.76 (24" RCP (N))STR. #748 MANHOLE, 5' DIA.; R-1772TC: 854.20INV. IN 849.50 (18" RCP (NE))INV. IN 847.43 (18" RCP (S))INV. IN 848.03 (12" RCP (W))INV. OUT 847.33 (24" RCP (N))STR. #760 INLET M; R-3010TC: 852.25INV. OUT 848.40 (12" RCP (E))FG EG FG EGFG EG 95' 0.25% 24" RCP 189' 0.25% 24" RCP 68' 0.55% 12" RCPSTR. #748 MANHOLE, 5' DIA.; R-1772TC: 854.20INV. IN 849.50 (18" RCP (NE))INV. IN 847.43 (18" RCP (S))INV. IN 848.03 (12" RCP (W))INV. OUT 847.33 (24" RCP (N))(PRIVATE) (PRIVATE) (PRIVATE)(PRIVATE) (PRIVATE) 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANAFORCARMEL CLAY SCHOOLSNEW ELEMENTARY SCHOOLSDrawing Title: 11-19-19 SO MK 18094 Rev. #Revision Description Issue Date STORM SEWER PLAN SCALE:HORZ.: 1"=30' VERT.: 1"=3' GENERAL NOTES LEGEND Existing Grade New Grade Granular Backfill SCALE: 1" = 30' C508 PLAN & PROFILE (STORM) 1 TAC COMMENTS 12/20/2019 The storm sewer system shall be constructed per design specified and as approved by the City of Carmel on the final approved construction plans. Deviations from the approved design shall only be permitted due to special circumstances or difficulty during construction and will require prior field approval from a designated representative of the City of Carmel in addition to supplemental approval by the design engineer. An explanation of any such deviation shall be included as a requirement on as-built/record drawings submitted for release of performance guarantees. Approved design slopes identified as generating velocities of 2.5 fps or less or 10 fps or greater (at full flow capacity) shall require as-built certification at the time of construction, prior to backfilling the pipe. The contractor is instructed to as-built each section of storm pipe as it is being installed to ensure compliance with the design plans and as approved by the City of Carmel. AS-BUILT NOTES 2 TAC COMMENTS 1/3/2020 2 GRANULAR BACKFILL NOTES ·For RCP storm pipe granular backfill, refer to detail 3, sheet C601. ·For HDPE storm pipe granular backfill, refer to detail 4, sheet C601. ·For PVC sanitary sewer, see Carmel Utilities Trench Detail & Trench Schedule on sheet C606.