HomeMy WebLinkAboutC513 - PLAN & PROFILE (SANITARY) (V2)STR. #D Manhole, 4' Dia.; R-1772TC: 854.28STR. #C Manhole, 4' Dia.; R-1772TC: 853.13STR. #A Drop Manhole, 4' Dia.; R-1772TC: 854.50STRUCTURE B,A,C,D 199' 1. 9 7 % 8 " H D P E 68' 0.50% 8" HDPE 156' 0.50% 8" HDPESTR. #B MANHOLE, 4' DIA.; R-1772TC: 852.85INV. OUT 847.00 (8" HDPE (SW))FG EG FG EG (PRIVATE) (PRIVATE) (PRIVATE)OHUOHUOHUOHUOHUOHUOHUOHUWWWWWWWFDCTTPTPTPTPTPTPTP TPTPTPTP TP TP TPTPTPTPTPBUSONLY TP C.O.TYPE II C.O.TYPE II C.O.TYPE II6''SSD6''SSD6''SSD6' ' S SD 6' 'SS D6''SSD6'' S S D 6'' S S D6''SSD6 ' 'SSD 6 ' 'SSD6''SSD6''SS D 6''SS D 6' ' S S D 6''SSD 6''SSD 6''SSD6''SSD 6''SSD 6''SSD6''SSD 6''SSD 6''SSD6''SSD6''SSD6''SSD4"6"DOMFIREPRD RD RD RDRDRDRDRDRD NO PA R KI N G 6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD 6''SSD6''SSD6''SSD6''SSD758 RIM=855.00 752 RIM=854.70 759 RIM=854.50 762 RIM=854.80 751 RIM=853.20 748 RIM=854.20 753 RIM=853.10 750 RIM=852.70 749 RIM=852.50 747 RIM=851.75 760 RIM=852.25746 RIM=852.20 RIM=851.90 761 RIM=851.80 756 RIM=851.30 787 RIM=851.50 757 RIM=851.30 782 RIM=851.00 64' OF 1 2 " R C P @0.31%112' OF 12" RCP@0.31 % 30' OF 12" RCP @0.33% 23' OF 15" RCP @0.30% 61' O F 1 8 " R C P @0.2 5 % 189' OF 24" RCP @0.25% 95' OF 24" RCP @0.25% 6 5 ' O F 1 2 " R C P@0 . 2 8%68' OF 12" RCP@0.55%24' OF 15" RCP @0.85% 67' OF 18" RCP @1.05% 10' OF 12" RCP @1.52%80' OF 12" R CP @0.50 % 1 6 1 ' O F 1 2 " R C P@0 . 6 9% 29' OF 12" RCP @0.45%199' OF 8 " HDPE@1.97%261' OF 8" HDPE@0.50%68' OF 8" HDPE @0.50% 156' OF 8" HDPE @0.50%PI0+79.531. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. C513 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANAFORCARMEL CLAY SCHOOLSNEW ELEMENTARY SCHOOLSDrawing Title: 11-19-19 SO MK 18094 Rev. #Revision Description Issue Date SANITARY SEWER PLAN GENERAL NOTES SCALE: 1" = 30' PLAN & PROFILE (SANITARY) SCALE:HORZ.: 1"=30' VERT.: 1"=3' LEGEND Existing Grade New Grade Granular Backfill The storm sewer system shall be constructed per design specified and as approved by the City of Carmel on the final approved construction plans. Deviations from the approved design shall only be permitted due to special circumstances or difficulty during construction and will require prior field approval from a designated representative of the City of Carmel in addition to supplemental approval by the design engineer. An explanation of any such deviation shall be included as a requirement on as-built/record drawings submitted for release of performance guarantees. Approved design slopes identified as generating velocities of 2.5 fps or less or 10 fps or greater (at full flow capacity) shall require as-built certification at the time of construction, prior to backfilling the pipe. The contractor is instructed to as-built each section of storm pipe as it is being installed to ensure compliance with the design plans and as approved by the City of Carmel. AS-BUILT NOTES 1 TAC COMMENTS 1/3/2020 1 GRANULAR BACKFILL NOTES ·For RCP storm pipe granular backfill, refer to detail 3, sheet C601. ·For HDPE storm pipe granular backfill, refer to detail 4, sheet C601. ·For PVC sanitary sewer, see Carmel Utilities Trench Detail & Trench Schedule on sheet C606.