Loading...
HomeMy WebLinkAboutC603 - STORM DETAILS (V2)Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANAFORCARMEL CLAY SCHOOLSNEW ELEMENTARY SCHOOLSDrawing Title: 11-19-19 SO MK 18094 Rev. #Revision Description Issue Date C603 SCALE: NONE 24" min. CONCRETE COLLAR FOR CASTINGS WITHIN ASPH. 6" min. SECTION A-A CONCRETE COLLAR ROUND CASTING CASTING SQUARE CASTING CONCRETE 24" min. WITHIN ASPHALT AREAS CONCRETE COLLAR CJCJ CONTROL JOINTS CJ CJ NOTES: ALL INLET CASTINGS SHALL HAVE "NO DUMPING DRAINS TO STREAM" AND A FISH SYMBOL CAST INTO TOP OF CASTING. 1. STORM WATER SEWER DETAILS 1 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com Structure #: Drawn By: Scale: Date:6/26/2019 Rvwed Rvw. Date U.S. Patent No. 6524473 and other Patent Pending Aqua-Swirl XCelerator As Shown OFlores Aqua-Swirl Stormwater Treatment System Standard Detail XC-5 CCW STD XC-5 STD Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System 12 in [305 mm] Manhole Frame & Cover DetailFor Non-Traffic Areas OnlyNTS 4 in [1219 mm] Min. Gravel Backfill Concrete Wrap Compressible Expansion Joint Material to a minimum 1/2-inch [13 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Riser Soil Cover Frame 1/2 in [13 mm] 1/2 in [13 mm] Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Backfill (90% Proctor Density) 8 in [203 mm] 4 1/2 in [114 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Manhole Frame & Cover Detail For Traffic Loading Areas NTS Cover Frame 48 in[1219 mm] Min. Backfill (90% Proctor Density) 3,000 psi [20 MPa] (min) Concrete #4 [13 mm] Rebar @ 6 in [152 mm] Each Way 30 in [762 mm] Riser 1/2 in[13 mm] 4 1/2 in[114 mm] 14 in[356 mm] 1/2 in [13 mm] Thick Expansion Joint Material If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1/2-inch [13 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Please see accompanied Aqua-Swirl specification notes. See Site Plan for actual System orientation. Approximate dry (pick) weight: 2200 lbs [1000 kg]. Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Backfill Bedding Undisturbed soil 18 in [457 mm] 6 in [152 mm] 1 1 As an alternative, 42 in [1067 mm] diameter, HS-20/25 rated precast concrete rings may be substituted. 14 in [356 mm] thickness must be maintained. XC-5 inlet/outlet pipe size ranges up to 30 in [762 mm]. XC-5 chamber height may vary up to 111 in [2819 mm], depending on inlet/outlet pipe size. Orientation may vary from a minimum of 90° to a maximum of 180°. Clockwise or counterclockwise orientation as needed. 2 3 3 2 Plan View SCALE 1:40 72 in [1829 mm] 72 in [1829 mm] n30 in [762 mm] n30 in [762 mm]2 Octagonal Base Plate Ø60 in [Ø1527 mm] Elevation View SCALE 1:40 63 in [16 mm] 111 in [2819 mm] [914 mm][787 mm] 5 MH Frame [127 mm] n30 in [762 mm] Band Coupler by Manufacturer. (as needed) Riser Manhole Frame and Cover by Manufacturer. (See Details) Rim elevations to match finish grade. Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. 4 4 el. Varies Inlet/Outlet Invert el. Varies el. Varies Grade (Rim) el. Varies Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. 180° n60 in [1524 mm] Projected View SCALE 1:70 Optional inlet orientations available (See note 4) 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com Structure #: Drawn By: Scale: Date:6/26/2019 Rvwed Rvw. Date U.S. Patent No. 6524473 and other Patent Pending Aqua-Swirl XCelerator As Shown OFlores Aqua-Swirl Stormwater Treatment System Standard Detail XC-6 CCW STD XC-6 STD Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System 12 in [305 mm] Manhole Frame & Cover DetailFor Non-Traffic Areas OnlyNTS 4 in [1219 mm] Min. Gravel Backfill Concrete Wrap Compressible Expansion Joint Material to a minimum 1/2-inch [13 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Riser Soil Cover Frame 1/2 in [13 mm] 1/2 in [13 mm] Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Backfill (90% Proctor Density) 8 in [203 mm] 4 1/2 in [114 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Manhole Frame & Cover Detail For Traffic Loading Areas NTS Cover Frame 48 in[1219 mm] Min. Backfill (90% Proctor Density) 3,000 psi [20 MPa] (min) Concrete #4 [13 mm] Rebar @ 6 in [152 mm] Each Way 30 in [762 mm] Riser 1/2 in[13 mm] 4 1/2 in[114 mm] 14 in[356 mm] 1/2 in [13 mm] Thick Expansion Joint Material If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1/2-inch [13 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Please see accompanied Aqua-Swirl specification notes. See Site Plan for actual System orientation. Approximate dry (pick) weight: 3000 lbs [1400 kg]. Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Backfill Bedding Undisturbed soil 18 in [457 mm] 6 in [152 mm] 1 1 As an alternative, 42 in [1067 mm] diameter, HS-20/25 rated precast concrete rings may be substituted. 14 in [356 mm] thickness must be maintained. XC-6 inlet/outlet pipe size ranges up to 36 in [914 mm]. XC-6 chamber height may vary up to 128 in [3251 mm], depending on inlet/outlet pipe size. Orientation may vary from a minimum of 90° to a maximum of 180°. Clockwise or counterclockwise orientation as needed. 2 3 3 2 Plan View SCALE 1:40 84 in [2134 mm] 84 in [2134 mm] n36 in [914 mm] n36 in [914 mm] 2 Octagonal Base Plate Ø72 in [Ø1832 mm] Elevation View SCALE 1:40 74 in [188 mm] 128 in [3251 mm] [1067 mm][940 mm] 5 MH Frame [127 mm] n30 in [762 mm] Band Coupler by Manufacturer. (as needed)Riser Manhole Frame and Cover by Manufacturer. (See Details) Rim elevations to match finish grade. Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. 4 4 el. Varies Inlet/Outlet Invert el. Varies el. Varies Grade (Rim) el. Varies Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. 180° n72 in [1829 mm] Projected View SCALE 1:70 Optional inlet orientations available (See note 4) This is a sample detail, please contact AquaShield, Inc. for more information. 1. Where high groundwater elevations are present or anticipated, Contractor shall supply concrete anti-floatation pad and pour around the octagonal base plate of the swirl (as shown) to prevent buoyancy. GENERAL NOTES: Hc Varies (10" [254 mm] min) Description of Revision Treatment System Aqua-Swirl Stormwater Anti-Floatation Ring Detail www.aquashieldinc.com Phone (888) 344-9044 Fax (423) 826-2112 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 STORMWATER TREATMENT SOLUTIONS U.S. Patent No. 6524473 Scale: Date: Drawn By: Document:Rev. DateConcrete Pad Detail JCW 04/21/15 NTS Concrete Anti-Floatation Pad STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ Wc Varies Gravel Backfill Gravel Backfill Undisturbed Soil Undisturbed Soil Grade (Rim) Bedding Wc Varies Wc Varies May also be a square pad of width = Wc Aqua-Swirl Chamber Octagonal Base Plate Octagonal Base Plate Concrete Anti-Floatation Pad Rim elevations to match finished grade. Manhole Frame and Cover by Manufacturer Riser Aqua-Swirl Chamber Plan View Section A-A A A USE THIS FOR XCELERATOR UNITS 2 DIVERSION MANHOLE STRUCTURE 742 NOT TO SCALE 3 4 7' Ø MANHOLE DIVERSION MANHOLE STRUCTURE 772 NOT TO SCALE DIVERSION MANHOLE STRUCTURE 712 NOT TO SCALE 7' Ø MANHOLE 7' Ø MANHOLE 1 ADDENDUM # 3 12/20/2019 1 1