Loading...
HomeMy WebLinkAboutC504 - PLAN & PROFILE (STORM) (V2)OHUOHUOHUOHUOHUOHUOHUOHUOHUOHUBUSONLY6''SSD 6''SSD 6''SSD6''SSD 6''SS D 6''SSD6''SSD 6''SSD 6' 'SSD 6''SSD 6''SSD 6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD6''SSD6''SSDRD RDR D R D RDRD R D RDRD R D R D R D R D R D R D R D R D R D NO PARKING C .O . T Y P E I C .O . T Y P E I C .O . T Y P E I C .O . T Y P E I 730 RIM=855.10 722 RIM=854.80 725 RIM=854.75 729 RIM=854.30 719 RIM=854.20 721 RIM=854.10 728 RIM=854.00 727 RIM=854.00 720 RIM=852.90 718 RIM=852.90 24' OF 15" RCP 73' OF 12" R CP @0.55 % 75' O F 1 2 " R C P @ 0 . 5 3 %106' OF 18" R CP @0.38 %105' OF 24" R CP @0.29 %116' OF 24" RCP@0.30%7 4 ' O F 1 2 " H D P E@0. 8 1%54' OF 12" HDPE@0.56 % 9 8 ' O F 1 2 " R C P@0 . 6 1% 5 3 ' O F 1 2 " H D P E@1 . 1 3%427' OF 8" H DPE @0.50 % 26 1 ' O F 8 " H D P E STR. #730 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 855.10INV. OUT 851.10 (12" HDPE (SE))STR. #722 MANHOLE, 4' DIA.; R-1772TC: 854.80INV. OUT 849.90 (12" RCP (NE))STR. #721 MANHOLE, 4' DIA.; R-1772TC: 854.10INV. IN 850.50 (12" HDPE (NW))INV. IN 849.50 (12" RCP (SW))INV. OUT 849.40 (12" RCP (SE))STR. #720 MH 4' DIA; R-3405TC: 852.90INV. IN 849.00 (12" RCP (NW))INV. OUT 848.60 (18" RCP (NE)) 74' 0.81% 12" HD P E 73' 0.55% 12" RCP 75' 0.53% 12" RCP 106' 0.38% 18" RCP STR. #729 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 854.30INV. OUT 850.30 (12" HDPE (SE)) 53' 1.13% 1 2 " H D P E STR. #727 MH 4' DIA; R-3405TC: 854.00INV. IN 849.70 (12" HDPE (NE))INV. IN 849.70 (12" HDPE (NW))INV. OUT 849.60 (12" RCP (SE))STR. #728 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 854.00INV. OUT 850.00 (12" HDPE (SW)) 54' 0.56% 12" HDPE STR. #727 MH 4' DIA; R-3405TC: 854.00INV. IN 849.70 (12" HDPE (NE))INV. IN 849.70 (12" HDPE (NW))INV. OUT 849.60 (12" RCP (SE)) 98' 0.61% 12" RCP STRUCTURE 730,721 STRUCTURE 722-719 STRUCTURE 729,727 STRUCTURE 728-727,719STR. #721 MANHOLE, 4' DIA.; R-1772TC: 854.10INV. IN 850.50 (12" HDPE (NW))INV. IN 849.50 (12" RCP (SW))INV. OUT 849.40 (12" RCP (SE))STR. #719 MANHOLE, 4' DIA.; R-1772TC: 854.20INV. IN 848.20 (18" RCP (SW))INV. IN 849.00 (12" RCP (NW))INV. OUT 848.10 (24" RCP (NE))STR. #719 MANHOLE, 4' DIA.; R-1772TC: 854.20INV. IN 848.20 (18" RCP (SW))INV. IN 849.00 (12" RCP (NW))INV. OUT 848.10 (24" RCP (NE))10 - YEAR HGL 10 - YEAR HGL 10 - YEAR HGL 10 - YEAR HGL FG EG FG EG FG EG FG EG (PRIVATE) (PRIVATE) (PRIVATE) (PRIVATE) (PRIVATE)(PRIVATE) (PRIVATE) 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANAFORCARMEL CLAY SCHOOLSNEW ELEMENTARY SCHOOLSDrawing Title: 11-19-19 SO MK 18094 Rev. #Revision Description Issue Date STORM SEWER PLAN SCALE:HORZ.: 1"=30' VERT.: 1"=3' GENERAL NOTES LEGEND Existing Grade New Grade Granular Backfill SCALE: 1" = 30' PLAN & PROFILE (STORM) C504 1 TAC COMMENTS 12/20/2019 The storm sewer system shall be constructed per design specified and as approved by the City of Carmel on the final approved construction plans. Deviations from the approved design shall only be permitted due to special circumstances or difficulty during construction and will require prior field approval from a designated representative of the City of Carmel in addition to supplemental approval by the design engineer. An explanation of any such deviation shall be included as a requirement on as-built/record drawings submitted for release of performance guarantees. Approved design slopes identified as generating velocities of 2.5 fps or less or 10 fps or greater (at full flow capacity) shall require as-built certification at the time of construction, prior to backfilling the pipe. The contractor is instructed to as-built each section of storm pipe as it is being installed to ensure compliance with the design plans and as approved by the City of Carmel. AS-BUILT NOTES 2 TAC COMMENTS 1/3/2020 2 GRANULAR BACKFILL NOTES ·For RCP storm pipe granular backfill, refer to detail 3, sheet C601. ·For HDPE storm pipe granular backfill, refer to detail 4, sheet C601. ·For PVC sanitary sewer, see Carmel Utilities Trench Detail & Trench Schedule on sheet C606.