Loading...
HomeMy WebLinkAboutT1.2 - SPECIFICATIONSP�� C�R PEDCOR DESIGN GROIIP Architedure / Project Managment: 355 Giry Genter Dnve Carmel, Intliana 46032 3177057979 (phone) 317705 7980 (fax) Amhilect: SPECIFICATIONS AND GENERAL NOTES o coNTRncTcoNoiTioNs 0.1 THEGENERALCONDITIONSSHALLBEAIADOCUMENTA201�2007EDITION, ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRl1CTI0N". THIS DOCl1MENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCW DED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASE� AS FOLLOWS: 32 STU�YTHECONTRACT�OCUMENTS,VERIFY�IMENSIONSAN� FIEL� CON�ITIONS AN� REPORT �ISCREPANCIE$ BEFORE PROCEE�ING WITH CONSTRUCTION. 3.3 SUPERVISE,�IRECTAN�COOR�INATETHEWORK,WITHSOLE RESPONSIBILITYAND CONTROLOVER CONSTRUCTION MEANS, METHODS,TECHNIQUES,SEQUENCESANDPROCEDURES. 3.7 OBTAINANDPAYFORTHEBUILDINGPERMITANDNECESSARY GOVERNMENTALFEES,LICENSESANDINSPECTIONS. 3.14 CUTANDPATCHEXISTINGSURFACESTOMATCHEXISTING ADJACENT SURFACES, USING EQUAL �UALITY MATERIALS AND WORKMANSHIP 1 �.1 INITIATE, MAINTNN AN D Sl1PERVISE PROJECT SAFETY PRECAl1TI0NS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 02 WORKMUS�COMPLYWITHAPPLICABLELAWS,CO�ES,OR�INANCES, RULES AN� REGULATIONS. 0.3 ALLMATERIALSANDEQUIPMENTSHALLBEOFINDUSTRYSTANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. 04 WHENNOTINDICATEDINTHECONTRACTDOCUMENTS,PROVIDETHE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BEfWEEN PIECES OF E�UIPMENT IN ORDERTO UTILIZETHE SPECIFIE� CAPACITIES OFTHE E�UIPMENT. 0.5 WHENNOTIN�ICATE�INTHECONTRACT�OCUMENTS,THESTAN�AR�S ESTABLISHE� BYTHE RECOGNIZE�TRA�EASSOCIATION HAVING JURIS�ICTION FOR THE PRO�UCT INCLU�E� IN THE PROJECT SHALL GOVERNTHEWORK. 0.6 NOTALLITEMSINDICATEDONTHEDRAWINGSAREINCLUDEDINTHESE SPECIFlCATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFlCATIONS OR WITHM EITHER ELEMENT NOT CIARIFIED BY ADDENDUM, THE BEfTER �UALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. �.7 INSTALL E�l11PMENT AND MATERIALS IN ACCORDANCE WITH MANl1FACNRER'S RECOMMENDATIONS. 1 GENERALREQUIREMENTS 1.1 THECONTRACTORISTOCOORDINATEWORKWRHALLOTHER CONTRACTORS ON SRE THROUGH THE BUILDING OWNER'S REPRESENTATIVE. L2 WORKSHALLBEPERFORMEDDURINGREGULARBUSMESSHOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON�REGUTAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT 13 THECONTRACTORSHALLCOORDINATEANDSCHEDULEWORKBYOTHERS INCWDING Bl1T NOT LIMITEDTOTELEPHONEIDATA, SECl1RITY, Fl1RNITl1RE AND"Fl1RNISHEDANDIORINSTALLED"ITEMS. CONTRACTORSHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE Cl1TTING, FITf ING, AN� PATCHING THAT MAY BE RE�l11RE� TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIE� BY THE �RAWINGS AN� SPECIFICATIONS. 14 CUTTINGOFEXISTINGSURFACESSHALLBEPATCHE�TOMATCHEXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP 1.5 9UBMIT9HOPDRAWING9(OR9UBMITTAL9�TOTHEARCHITECTFORTHE FOLLOWING ITEMS: .1 DOORS,FRAMESANDHARDWARE. 2 Sl1SPENDEDACOl1STICALCEILINGSYSTEMS(6"X6"ACOl1STICAL PANEL�. .3 FLOORINGAN�BASE(COLORSAMPLES�. �4 PLl1MBINGFIXTl1RES(PIAN&CATELOGCl1TS�. .5 PAINT(6"X6"ONACTUALSURFACE�. .6 WALLFINISHES(COLORSAMPLES�. .7 HVACDIFFUSERS,THERMOSTAT,ANDGRILLES(PLANS&CATALOGCUTS�. .8 LIGHTFIXil1RES(PLANANDCATALOGCl1TS�. .9 FIRESPRINKLERLAYOl1T. .10 FIREEXiINGUISHER(CAiALOGCUiS�. .fl ELECTRICALPLAN. 1.6 TEMPORARYl1TILRIES,INCWDINGWATER,SANITARYFACILITIES, ELEVATORS, TEMPORARY ENCLOSl1RES, FIRE PROTECTION, HEAT AND POWER WILL BE PROVI�E� BY THE OWNER, Sl1BJECT TO THE OWNER OR THE OWNER'S AGENTS �IRECTION. COMPLY WRH SPECIFIC BWL�ING CONSTRUCTION RULES PUBLISHE� BY THE OWNER OR THE OWNER'S AGENT 1.7 THECONTRACTORSHALLPROTECTTHEBWL�INGPREMISESAN� OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN N ECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FlNISHES TO REMAIN ATTHE JOB SITE. THECONTRACTORSHALLBEHELDRESPONSIBLEFORDAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPIACEMENT WRHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. 1.8 THECONTRACTORSHALLMAINTNNFORTHEENTIRELENGTHOFHIS CONTRACT EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL Bl11LDING CODE RE�l11REMENTS. 1.9 Sl16STITl1TI0NFORNAMEDPRODl1CTSWILLNOTBEALLOWEDWITHOl1T PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSE�, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDECOMPLEfEPRODUCTDATA,DRAWINGSANDDESCRIPTIONSOF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. 1.10 1.11 1.12 1.13 2 2.1 22 2.3 24 2.5 2.fi 2.7 28 29 210 2,11 5 S.1 6 fi.i 62 63 fi.4 2 PROVI�ESAMPLESWHEREAPPLICABLEORRE�l1ESTE�. .3 PROVI�ECOMPLETECOOR�INATIONINFORMATION,INCW�INGALL CHANGES RE�UIRE� IN OTHER ELEMENTS OFTHE WORKTO ACCOMMO�ATETHE SUBSTITUTION. 4 PROVIDEASTATEMENTINDICATINGHOWTHESUBSTITUTIONWILL AFFECTTHECONTRACTSUMANDCONTRACTTIME. STORE MATERIALS ON SITE PRIORTO INSTALLATION,ANDALLOWTIME FORTHEIRADJUSTMENTTOAVOID SHRINKAGE OR SWELLING. THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALLARRANGE FOR HOISTING, CARTING, ELEVATOR SERVICE, STANDARD AND OVERTIME SERVICES BYTHE BWLDING MANAGEMENTAND OVER�IME CHARGESAND EXPENSES WHEN RE�l11RED Dl1E TO Bl11LDING MANAGEMENT RE�l11REMENTS. PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL CLEANERS. CLEAN EACH Sl1RFACE OR 11NIT OF WORK TO THE CON�ITION EXPECTE� FROMA COMMERCIALBWL�ING CLEANINGAN� MAINTENANCE PROGRAM IN ACCOR�ANCE WRH THE MANl1FACTl1RER'S INSTRl1CTI0NS. PROVI�E OPERATINGAN� MAINTENANCE MANUALS WITH INFORMATION NECESSARY FOR THE SAFE AN� EFFICIENT OPERATION AN� MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE INSPECTION, CAREAND MAIMENANCE OR REPAIR OFARCHITECTURAL PRODUCTS AND FlNISHES WHICH ARE OTHER THAN BUILDING STAN DARD. DEMOLITION COORDINATE DEMOLITION WITH CONSTRl1CTI0N PLANS TO DEf ERMINE EXiENT OF WORK. PROVI�E �EMOLITION Sl1FFICIENT FOR SWTABLE BON �INGIPATCHING OF EXISTING CONSTRl1CTI0N TO REMNN WITH NEW WORK. WHERE WORK INCLU�ES REMOVAL OF EXISTING CONSTRUCTION OR EQUIPMENT,ORREMOVALANDPATCHING,REMOVALANDREPLACEMENT, OR REMOVALAND RELOCATION, SURFACES LEFT EXPOSED IN REUTION TO SUCH WORK SHALL HAVE ANY EXCE55 MATERIALS REMOVED, AND SURFACES SHALL BE PREPPED AND FlNISHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP ADJACENTITEMSSHALLBE REMOVEDANDRELOCATED TOALLOWSUCHWORK. NOCHANGEORDERWILLBEISSUEDFOR ADDITIONAL WORK RELATED TO Sl1CH ACTIVRIES. WHERE WORK INCLU�ES REMOVALAN� RELOCATION, RELATE� MECHANICALAN� ELECTRICAL CONNECTIONS AN� TERMINATIONS SHALL BEINCLU�E�. REPAIR �EMOLITION PERFORME� IN EXCE55 OF THAT REQUIRE� BY THE DRAWINGS. ON EXISTINGCONSTRUCTION�TO�REMAIN, THOROUGHLY REMOVE ADHESNE RESULTING FROM THE REMOVAL OF SURFACE APPLIED FlNISHES,INCLUDINGVINYLBASE, CARPETTILES,ETC. CHEMICALSAND METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WRH NEW FINISHES. ExISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURIING CONSTRUCTION OR NOTED TO BE REPAIRED. SAWAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. REPAIRAND RESTORE DESIGNATED REUSED EXISTING PRODUCTSAS REQUIRED TO MEET IN FINISHED FORM THE iYPE AND QUALIiY OF WORK IN SCOPE OF CONTRACT PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS ELEVATOR DOORWAYS, ExITSTAIR DOORWAYS, ETG CARPETMATS SHALL BE LARGE ENOUGH TO PREVENT THE HAULINGISPREA�ING OF �IRT THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. CONTRACTOR SHALL INSPECT, TESTAND DISCONNECT UTILIiY SERVICES AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILIiY SERVICESINUSE. CONTRACTORSHALLSECURELYCAPANDIORVAWE- OFF UTILIiY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO DEMOLITIONOPERATIONS. UTILIiYSERVICESHALLBEDEFINEDAS PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS CONTRACTOR SHALL INDICATE PERMANENTLYABANDONED UTILITIES ON A RECORD SEPIA TO SERVE AS PART OF THE "AS-BUILT" SET PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENTORCOLLAPSEOFSTRUCTUREORELEMENTTOBE DEMOLISHED, AND ADJACENT FAQLITIES OR WORK TO REMAIN, METAL FABRICATIONS PROVIDE STEEL FRAMING AND SUPPORT$ FOR APPLICATIONS INDICATED OR WHICHARE NOTAPARTOF STRUCTURAL STEEL FRAMEWORK,AS RE�UIRED TO COMPLETE WORK. WOOD AND PLASTIC CONCEALEDROUGHFRAMINGANDBLOCKING'. PROVIDE"CONSTRUCTION GRADE" LUMBER OF ANY SPEGES WITH MAXIMUM 19% MOISTURE CONTENT PLYWOODBACKINGPANELS'. FORMOUNTINGELECTRICALORTELEPHONE EQUIPMENT, PROVIDE FIRERETARDANT TREATED PLYWOOD PANELS, APA C-D PLUGGED INTWITH EXTERIOR GLUE, NOT LESSTHAN iS132" FIRE-RETAR�ANTTREATMENT PRESSUREIMPREGNATELUMBERAN� PLYW00� WITH FIRE-RETAR�ANT CHEMICALS TO COMPLY WITH AWPA C20 AN� C27, RESPECTNELY, AN� I�ENTIFY LUMBER WITH CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. FINISHCARPENTRYANDMILLWORK�. COMPLYWITH"PREMIUMGRADE"AWI STANDARDS. �� PROVI�ESHOP�RAWINGSFOROWNER',SAPPROVALPRIOR TO FABRICATION. 67 fi,8 6,9 fi.10 6,11 7 7.1 Z2 8 8.1 82 8.3 84 9 9.1 � � � :k7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH PROVISIONS FOR SCRIBING AS RE�UIRED TO MEET BUILT-IN CONDITIONS, DO NOT DELIVER CASEWORKAND FINISH CARPENTRY UNTIL PAINTING, WETWORK AND SIMIIAR OPERATIONS WHICH COULD DAMAGE FINISHED WORK HAS BEEN COMPLETED AND HVAC SYSTEMS H4VE BEEN PROPERLY OPERATING FOR TEN DAYS, INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND STRAIGHTWITH NO DISTORTIONS. JOINTS BEIN�EEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM WI�TH NOTTO ExCEE� 118 U.O.N. GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL OUTLETS, JOINT SEALERS ONEPART MILDEW�RESISTANT SILICON E SEAIANT � AT COUMERS, FlXTURES AND JOINTS IN TOILET ROOMS: 1 "DOWCORNING786'1DOWCORNINGCORP 2 "SCS1702SANITARY"',GENERALELECTRICCO. 3 "863#345WHITE"'PECORACORP 4 "PROGLAZEWHITE"',TREMCOCORP. .5 "OMNIPLl1S"',SONNEBORNBWLDINGPRODl1CTS ACRYLIGEMULSION SEALANT �AT INTERIOR UNLIKEA�JOINING SURFACES: 1 "CHEM�CALK600'1605TIKCONSTRUCTIONPRODUCTSDIV 2 "AG20'1PECORACORP. 3 "SONOLAC",SONNEBORNBUILDINGPRODUCTS 4 "TREMCOACRYLICLATEX834'1TREMCO,INC. 000es nNo wiNoows INTERIOR �OOR FRAMES: PROVI�E HOLLOW METALFRAME 11NLESSNOTE�OTHERWISE.FRAMESTOBEPREPPE�AN�PNNTE� INTHEFIEL�. COLORSPECIFIE�BY�ESIGNER. INTERIOR �OORS: AWI SECTION 1300 "PREMIl1M GRA�E" PRE�MACHINE� 5� PLYPGSPARTICLEBOAR�SOLI�CORE. WOO�VENEERFACES: PNNTGRA�E. .1 MANUFACTURER'SSTANDARDFACTORYRRIMED. 2 WARRANTYLIFETIMEWARRANTYONALLARCHITECTURALFLUSH WOOD DOORS, INCW DING THOSE DOORS WITH VIEW PANELS AN D LOUVERS. PROVI�E �RAFT COPY OF WARRANTY WITH SUBMITTALS. DOORHARDWARE BUILDINGSTANDARDWIADALEVERHANDLELATCHAND LOCKSETS. GIASS: MEETASTMC1036RE�UIREMENTSFORGLASSANDASTMC1048 RE�WREMENTS FOR HEAT�STRENGTHENED GLASS. FINISHES GYPSUMBOAR�WALLFRAMING: COMPLYWITHASTMC645. ,� INSTALL"ELIMINATOR"iYPEHEADTRACKATWALLSTERMINATING ATCEILING. USEPREFORMEDOUTSIDECORNERS. GYPSUM BOAR�: PRON�E 518"THICK REGULARAN�TYPE "X"TAPERE� E�GE GYPSUM BOAR� WITH GAWANIZE� STEEL TRIM ACCESSORIES AN� JOINTCOMPOUN�COMPLYINGWITHASTMC475. FINISHINACCOR�ANCE WITH ASTM C840 TO THE HIGHEST QUALITY STAN�AR�S. DRYWALLFlNISHING: A. COMPLYWITHASTMC840STANDARDSPECIFICATIONFORAPPLICATION AND FINISHING OF GYPSUM BOARD', GA 214 RECOMMENDED LEVELS OF GYPSUM BOARD FINISH', AND GA 216�2000 APPLICATION AND FINISHING OFGYPSl1MB0ARD', B. PROVIDEGYPSl1MWALlBOARDMINIMl1MFINISHLEVELSMEETINGTHE CRITERIA ESTABLISHED IN GA 214 AS FOLLOWS: 1. LEVELI�GYPSl1MWALLBOAR�PERMANENTLYCONCEALE�FROMVIEW. 2. LEVEL2�GYPSl1MWALLBOAR�BEHIN�ANAPPLIE�WALLCOVERING, AND WALLS AND CEILINGS IN MECHANICAL AND E�l11PMENT ROOMS. 3. LEVEL4�GYPSl1MWALLBOARDONINTERIORWALLSFORALLTENANTSPACES. 4. LEVELS�GYPSl1MWALlBOARDONALLFINISHEDCEILINGSANDALLCOMMONAREAWALLS. PORCEIAINTILE�, INSTALLTILEINACCORDANCEWITHTILECOUNCILOF AMERICAGUIDELINES, .1 PROVI�EFACTORY-MA�ECORNERAN�TRIMSHAPES. MAKE INSIDE CORNERS S�UARE WITH FULL OR CUT FIELD TILES�, OUTSIDECORNERSWITHCORNERSHAPES�, WALL-TO-FLOOR CORNERS WITH COVE SHAPES, JOINTS TO MATCH UP. CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRl1E AND FREE FROM DAMAGED OR SOILED TILES. .1 COORDINATEPIACEMENTOFMECHANICALANDELECTRICALITEMS IN CEILING. WHERE CONFl1CTS OCCUR, THE ARCHITECTURAL REFLECTED CEILING PIAN SHALL GOVERN. 2 CENTERCEILINGELEMENTSINCEILINGTILE,INCLl1DINGDOWN LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS 11NLESS NOTE� OTHERWISE. INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF �OOR OR CASE� OPENING UNLE55 NOTE� OTHERWISE. .1 INSTALL JOHNSONITE TRIM STRIPS AT �OOR WHERE CARPEf MEEfS RESILIENTTILE WRH TRIM STRIP COLORTO MATCH CARPEf. 9.6 RESILIENTFLOORING�, ,1 UNLESSOTHERWISENOTED,LAYTILEFROMCENTERMARKS ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH, ADJUST TO AVOID USE OF CUT WIDTHS LE55 THAN 3"AT ROOM PERIMETER, 2 BASE�, FITJOINTSTIGHTANDVERTICALONCONTINUOUSSOLID BACKING INSTALLBASEINLONGESTPRACTICALLENGTHS,USING ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. 97 USEANAPPROVE�CEMENTITIOUSFILLERTOPATCHCRACKS,SMALL HOLESAN�LEVELING.ENSURETHATFLOORSARELEVELWITH MAXIMUM SURFACE VARIATION OF Y"IN 10 FEET, NON�CUMULATIVE. 9.8 CARPET INSTALLCARPETINGWHICHMEETSTHEFOLLOWING STANDARDS: FLAMMABILITY: ASTM2859 Sl1RFACEBl1RNING: ASTME84 SMOKEDENSITY: ASTME662 SOl1NDABSORPTION: ASTMCA23 FA�ERESISTANCE: AATCCi6E STATIC RESISTANCE: AATCC 134 WARRANTY: 10YEARS .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. 9.10 PAINT:l1SEPRIMERCOMPATIBLEWRHSl16STRATE. REMOVEOR PROTECT HAR�WARE, PLATES AN � SIMILAR TRIM. AFTER PAINT IS �RY, REINSTALL SUCH ITEMS. .1 INTERIOR PAINT SCHE�ULE: PROVI�E THE FOLLOWING PAINT SYSTEMS BASE� ON �EVOE TO ESTABLISH QUALITY STAN�AR� FOR THE VARIOUS SUBSTRATES, AS INDICATED. 1. FERROUS METAL: A. ACRYLICSEMFGLOSSENAMELFlNISH: 1. PRIMER: 1 COATtt41702METALCLADACRYLIC LATEX PRIMER. 2. FINISH:2COATS#83XXMIRROLAGWBACRYLIC SEM4GLOSSENAMEL. 2. NON�FERROl1S METAL: A ACYRLICSEM4GLOSSENAMELFINISH: 1. PRIMER:iC0ATp417�2MEfALCLADACRYLIC LATEX PRIMER. 2. FINISH:2COATSd83XXMIRROLACE�WBACRYLIC SEMI�GLO55 FINISH 3. FERROUS STRUCTURE: A. ACRYLIC�RYFOGFLATFINISH: 1. FINISk2C0AT5�57601UNI�GRIP�WHWATER REDUCIBLE ACRYLIC DRY FOG COATING 4. NON�FERROUSSTRUCTURE: A. ACRYLICDRYFOGFLATFlNISH: L FlNISH:2COATS#57601UNI�GRIP�WBWATER REDUCIBLE ACRYLIC DRY FOG COATING. 8. WOOD'. A. ACRYLICLATEXSEMI-GLOSSENAMELFINISH'. 1. PRIMER'.iC0ATq51701WONDER-PRIMELATEX PRIMER-SEALER. 2. FINISH'.2COATSk83XXMIRROIAGWBARCYLIC SEMbGLOSSENAMEL. B. STAIN�VARNISHRUBBEDFINISH'. 1, FILLER�,iC0ATN4800WONDERW00DSTAIN PASTE WOOD FILLER (OPEN GRAIN WOODS�, 2 STAIN�,iC0ATq9fiXXWONDERW00DSTAIN ALKYD STAIN, 3, SEALER�,ICOATq4900WONDERW00D5EALER �UICK DRY SEALER, 4. FINISH�.2COATSWtfi00WON�ERW00�5TAIN ALKY� S4TIN VARNISH. 10, GYPSUMWALLBOARD�, A. ACRYLICLATExSATINENAMELFINISH�. 1. PRIMER�.iC0ATq50801WONDERTONESLATEx PRIMER-SEALER. 2. FINISH'.2COAT5#35XXWONDERTONEACYRLIC LATEXSATIN ENAMEL. 9.11 WALLCOVERING:APPLYWALLCOVERINGSECl1RE,SM00TH,CLEANAND WITHOl1TWRINKLES, GAPS OR OVERIAPS. .1 KEEPSEAMSTOAMINIMUM.HORIZONTALSEAMSARENOT ACCEF�ABLE. 2 SEAMSMUSTBEATLEAST2"FROMINSI�ECORNERSAN�6"FROM ouTsioe coRNeRs. 10 SPECIALTIES �p� FIREEX�INGUISHERSAN�CABINEiS: BWL�INGSTAN�AR�,ORIFNO BWL�ING STAN�AR�, PROVI�E JL IN�USTRIES "AMBASSA�OR" SERIES, SEMI RECESSE�, �UO�PANEL, FIEL� PAINTE�. 12 FURNISHINGS 12.1 CASEWORK: MANUFACTURERS: PROVI�E PRO�UCTS BY ONE OF THE FOLLOWING: .1 LSICORPORATIONOFAMERICAINC. 2 MONITOR�,�IVISIONOFLJKELLEYCO. 3 STEVENSCABINEfCO.,INC. 15116 �sns.o 15116.1 151162 151163 151164 15116.5 15116.6 15116] 15116.8 15116.9 15116.10 15116.11 15116.12 15116.13 GN GN.1 GN2 GN3 GN,4 GN5 GN6 GNI GN,B GN.9 GN10 I�iIiN7I�J[N9I.TiU7qIiNl3[N91 MEP SHELL SPEQFICATIONS: IN ADDITION TO THE NOTES BELOW, THE PREVIOUSLY ISSUE� SPECIFICATION FOR �VISIOIN iSAN� i6 SHALLBEAPPLICABLETOALLWORKUNDERTHESECONTRACTDOCUMENTS. COPIES OF THESE SPECIFICATIONS ARE AVNLABLE FROM THE ARCHRECT (PEDCOR �ESIGN GROUP) AN�iHE GENERAL CONTRACTOR (SIGNATURE CONSTRUC110N�. MECHANICAL QNCLl1�ING PW MBING, FIRE PROTECTIN AN� HVAC) AN� ELECTRICAL SYSTEMS ARE TO BE �ESIGNE� AN� CONSTRUCTE� BY THE RESPECTIVE �ESIGNIBWL� CONTRACTORS OR SUBCONTRACTORS ACCOR�ING TO CRITERIA �EFINE� BY THE TENANT AN� AESTHETIC CRITERIA(ONLY�DEFINEDBYTHEARCHITECT. THECONTRACTORSHALL BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, INSTALlATION AND INTERSYSTEM COORDINATION OF MECHANICAL AND ELECTRICALSYSTEMS. GEN ERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF DESIGNIBUILD DRAWINGS FOR FIRE PROTECTION, MECHANICAL, AND PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A CERTIFIED ENGIN EER. IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S DRAWINGS IN LOCATION OF TERMINAL MATERIALSIE�l11PMENT, Sl1CH AS DIFFl1SERS, GRILLES, LIGHTS QF SHOWN ON REFLECTED CEILING PLAN) AN� Sl1RFACE MOl1NTE� ELECTRICAL �EVICES, THE ARCHITECTl1RAL �RAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF �ISCREPANCIES AN� OBTAIN WRRTEN CLARIFICATION PRIOR TO PROCEE�ING WRH WORK. SUBMIT FIRE SPRINKLER LAYOUT FOR COOR�INATIONIAPPROVAL BY THE OWNERORTHEOWNER'SAGENT PATTERNOFSPRINKLERLAYOUT SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL COORDINATE WITH OTHER CEILING COMPONENTS. DESIGNIBUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OWNER'S AGENT OUTLETIJUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED WITH THE E�l11PMENTIAPPLIANCE FOR WHICH IT WAS DESIGNATED. VERIFY E�WPMENT MOl1NTING RE�WREMENTS FOR SCHEDl1LED E�l11PMENT. SWITCHESSHALLBEGANGEDl1NDERONEPUTE. DIMMERSSHALLBE GANGE� 11NLESS OTHERWISE NOTE� BY MANl1FACTl1RER. �ATAAN� COMMl1NICATION CABLES ARE PROVI�E� BY OTHERS AN� INSTALLE� BY OTHERS UNLE55 OTHERWISE NOTE�. CONTRACTOR SHAl1 COOR�INATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AN� TENANT'S VEN �ORS TO �ETERMINE THE PHASE �URING WHICH THE INSTALUTION SHALL OCCUR. DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF OUTLETS, UNLE55 OTHERWISE NOTED. ALL SWITCHES AND SWITCHPlATES SHALL BE BUILDING STANDARD COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE IVORY WHERE FLOOR MONl1MENTS ARE SHOWN NEXi TO EACH OTHER, THEY SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL PROVIDING PROPER ACCESS TO RECEPTACLES. IF ADDITIONAL Ol1TLETS RE�l11RED, COORDINATE WRH ARCHITECTl1RAL FOR SPEQFIC LOCATION. CONTRACTOR SHALL MARKALLPOWERAN� COMMl1NICATION Ol1TLEf LOCATIONS ON SLAB AN� PROVI�E ACCESS TO SITE FOR ARCHITECT TO OBSERVE PRIORTOANY COMMENCEMENT OF "ROUGH�IN" CONSTRUCTION. GENERALNOTES CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONSAND REPORTANY DISCREPANGES FROM THIS PIAN TO DESIGNER PRIOR TO PROCEEDING WITH CONSTRUCTION. DIMENSIONS ARE AS FOLLOWS UNLESS OTHERWISE NOTED'. A. TO FINISHED FACE OF GYPSUM BOARD. B, TOINSIDEFACEOFJAMBATDOORSANDOTHEROPENINGS C, TOTOPOFFINISHEDFLOORS D, TOBOTTOMOFFINISHEDCEILINGS, SEE WALL LEGEND FOR SYMBOLS REIATED TO WALL CONSTRUCTION, ExISTING CONSTRUCTION AND WALL TYPES, TERMINATE WALLSAT UNDERSIDE OF CEILING UNLESS INDICATED OTHERWISE. �ONOTSCALE�RAWINGS. WRITTEN�IMENSIONSGOVERN. PARTITION LOCATIONS, DIMENSIONS AND iYPES, DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, NOTIFY DESIGNER FOR WRITTEN CU+RIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION. CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUTTHIS OBSERVATION, FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOTVARY BY MORE THAN'/<" IN 20'-0" NON- CUMULATNE NOTIFYDESIGNERIFTOLERANCEISExCEEDED, CONTRACTOR SH4LLCOOR�INATE PIACEMENTOF BLOCKING PRIOR TO CLOSE-IN OF WALLS. SOUN� INSULATE� AN� FIRE RATE� PARTITIONING SHALL BE CAULKE� AT PERIMETERWITHACOUSTICALOR FIRE RATE� SEALANTASAPPLICABLE. PLACESEALANTBETWEENGYPSUMBOARDANDADJACENTSUBSTRATE. PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED TO STUD FRAMING. ATTHESE PARTITIONS, BACKTO BACK ELECTRICAL JUNCTION BOXES ARE NOT PERMITTED. ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY CONTRACTOR. 00033126 � s1a1e or , � aoos.aauceuueao. : HPNOVERPLPCESUITE285 �'L1--`T1 2ND FLOOR N KEY PLAN � N T.S. �eveloper: P� pE D C O R oEVE�dPMENi c��� r Prqed: �.�..� � Q � J •- � � L (6 � w ccv � � �� � � � Z � �U�Q�� �i+ - NQ � � � Q wQ N () 00 � � z }+ _ M �J,J � f !1 � L.IJ z (n w VJ � � J c N��w � U � � � Q �U Q � U � � � O O � CONSTRUCTION DOCUMENTS Issue Oale Orawn By Checketl By fll&2019 TJ MC Revlslons: Slale Release SeL 11/8/19 Projed Number sheet iitle: SPECIFICATIONS Sheet Number RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �i `��¢m�' lamn�Ml1 � DATE: O1I3O/ZO ►l� 1 �� • I��