Loading...
HomeMy WebLinkAboutBaldwin-Chamberss-Bldg-Pedcor---Backflow TestingSprinkler Inspection Certificate For Baldwin Chamberss Bldg Pedcor - 61155 800 South Rangeline Road Carmel, IN 46032 Tested to NFPA 25 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Inspection Date Oct 25, 2019 Building: Baldwin Chamberss Bldg Pedcor - 61155 Company: Dalmatian Fire Contact: Mike Polston Contact: Chad Schmidt Title: Manager Title: inspector Page of 1 7Dalmatian Fire 11/21/2019 Executive Summary Generated by: BuildingReports.com Building Information Building: Baldwin Chamberss Bldg Pedcor - 61155 Contact: Mike Polston Address: 800 South Rangeline Road Phone: 317-690-0325 Address: Fax: City/State/Zip: Carmel, IN 46032 Mobile: Country: United States of America Email: mpolston@pedcor.net Inspection Performed By Company: Dalmatian Fire Inspector: Chad Schmidt Address: 5670 West 73rd Street Phone: 317-664-0182 Address: Fax: City/State/Zip: Indianapolis, IN 46278 Mobile: Country: United States of America Email: scmidtbeer21@gmail.com System Control Unit System Type System Location Protected Area Devices Wet Pipe 20 Inspection Summary Category: Total Items Serviced Passed Failed/Other Qty %Qty %Qty %Qty % Device 5 25.00%5 100.00%5 100.00%0 0% Alarm 4 20.00%4 100.00%4 100.00%0 0% Valve 8 40.00%8 100.00%8 100.00%0 0% Hose 1 5.00%1 100.00%1 100.00%0 0% Pump 1 5.00%1 100.00%1 100.00%0 0% Sprinkler 1 5.00%1 100.00%1 100.00%0 0% Totals 20 100%20 100.00%20 100.00%0 0% Certification Company: Dalmatian Fire Building: Baldwin Chamberss Bldg Pedcor - 61155 Inspector: Chad Schmidt Contact: Mike Polston Signed: Nov 1, 2019 Signed: Nov 1, 2019 Page of 2 7Dalmatian Fire 11/21/2019 Inspection & Testing Generated by: BuildingReports.com Building: Baldwin Chamberss Bldg Pedcor - 61155 The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or . Items are listed by Category. Each item includes the services performed, and the time & date at which testing Failed/Other occurred. Device Type Location Service Time Date Passed Wet Pipe Pressure Switch 139 dry system Annual 11:21:05 AM 10/25/2019 Pressure Switch 139 dry system Annual 11:21:50 AM 10/25/2019 Tamper Switch outside Annual 11:28:25 AM 10/25/2019 Waterflow Switch 139 wet system Annual 11:11:50 AM 10/25/2019 Drain 139 dry system Annual 11:20:16 AM 10/25/2019 Drain 139 wet system Annual 11:13:19 AM 10/25/2019 Gauge 139 dry system Annual 11:17:23 AM 10/25/2019 Gauge 139 dry system Annual 11:18:14 AM 10/25/2019 Gauge 139 wet system Annual 11:14:11 AM 10/25/2019 Fire Dep't Connection outside Annual 2:23:08 PM 10/25/2019 Air Compressor 139 dry system Annual 11:22:26 AM 10/25/2019 Sprinkler Box 139 Annual 11:25:37 AM 10/25/2019 Backflow Prevention 139 top Annual 11:04:32 AM 10/25/2019 Backflow Prevention 139 Bottom Annual 11:07:03 AM 10/25/2019 Backflow Prevention 139 Annual 11:08:39 AM 10/25/2019 Control Valve 139 dry system Annual 11:15:45 AM 10/25/2019 Control Valve 139 wet system Annual 11:10:19 AM 10/25/2019 Control Valve 139 wet system Annual 11:11:31 AM 10/25/2019 Dry Pipe Valve 139 dry system Annual 11:18:47 AM 10/25/2019 Post Indicator Valve outside Annual 11:29:35 AM 10/25/2019 Page of 3 7Dalmatian Fire 11/21/2019 Wet Pipe Fire Sprinkler Systems Generated by: BuildingReports.com Building: Baldwin Chamberss Bldg Pedcor - 61155 This section lists out all the devices and components that have been associated with a Wet Pipe System and provides details as to type of component, pressure readings, response time, etc. If a component has an OK checkbox that is checked, then that component was actually tested. However, for Pass/Fail test results, see the Inspection and Testing section. Air Compressor Location Mfr.Model #Phase On psi Off psi Serial No. 139 dry system C-Aire S261R- LD1- 115PD 1 21 30 CA201901128 Type Description Rated Speed Horsepower Volts Amps OK ScanID Automatic Tank 1 120 9 53758765 Alarms Pressure Switch Type Description Manufacturer Low High Zone/Address OK ScanID Low Supervisory Potter Electric 14 1 53758761 Pressure Switch Alarm Potter Electric 1 53758762 Tamper Switch Type Description Manufacturer Zone/Address OK ScanID Lever Supervisory Potter Electric 1 53758767 Waterflow Switch Type Manufacturer Model #Sec Size Zone/Address OK ScanID Vane Potter Electric VSR 60 6 1 53758755 Components Backflow Prevention Manufacturer Model #Size Type Service Type Install Date WATTS LF009M2QT 2" Reduced Pressure Potable 10/25/2019 ScanID Water Purveyor Location Meter Account #Serial Number 53758750 139 top 1544645904 091675 Initial Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker 10.1 9.8 2.3 Held At Repairs or Notes Final Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker Page of 4 7Dalmatian Fire 11/21/2019 Held At Condition of Control Valve 1 Condition of Control Valve 2 Backflow Prevention Manufacturer Model #Size Type Service Type Install Date WATTS LF009M2QT 2" Reduced Pressure Potable 10/25/2019 ScanID Water Purveyor Location Meter Account #Serial Number 53758751 139 Bottom 1544550618 091681 Initial Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker 9.4 9.1 2.4 Held At Repairs or Notes Final Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker Held At Condition of Control Valve 1 Condition of Control Valve 2 Backflow Prevention Manufacturer Model #Size Type Service Type Install Date Wilkins 350A 6" Double Check Fire Line 10/25/2019 ScanID Water Purveyor Location Meter Account #Serial Number 53758753 139 U51747 Initial Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker Held At Repairs or Notes Final Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker Held At Condition of Control Valve 1 Condition of Control Valve 2 4.0 2.5 Control Valve Type Manufacturer Model Location Size Position Status OK ScanID Butterfly Victaulic 139 dry system 3" Open Supervised 53758763 Description Main Control Control Valve Type Manufacturer Model Location Size Position Status OK ScanID Butterfly Wilkins 49 139 wet system 6" Open Supervised 53758752 Description Page of 5 7Dalmatian Fire 11/21/2019 Main Control Control Valve Type Manufacturer Model Location Size Position Status OK ScanID Butterfly Wilkins 49 139 wet system 6" Open Supervised 53758754 Description Main Control Dry Pipe Valve Manufacturer Model #Location Internal Date OK ScanID Viking F-2 139 dry system 10/25/2019 53758758 Type Status Position Size Serial # Grooved Sealed 3" W856521 Water psi Air Pressure Trip Air Trip Time Total Timing (sec) Partial Trip Date Full Trip Date 50 25 7 10/25/2019 10/25/2019 Post Indicator Valve Manufacturer Model Location AWWA outside Type Position Status Size OK ScanID Wall Open Supervised and locke 6" 53758768 Devices Drain Current Inspection Type Location Size Supply psi Restored psi Residual psi Sec OK ScanID Main 139 dry system 1.5" 50 48 53758764 Type Location Size Supply psi Restored psi Residual psi Sec OK ScanID Combination 139 wet system 2" 55 48 60 53758757 Fire Dep't Connection Location Type BallDrip Rotating Swivels Size OK ScanID outside Storz No 4" pipe 53758769 Gauge Location Service Date 139 dry system 10/25/2019 Type Manufacturer Model #Static psi Fill Type Size OK ScanID Supply Pressure Viking 50 1/4 53758760 Gauge Location Service Date 139 dry system 10/25/2019 Type Manufacturer Model #Static psi Fill Type Size OK ScanID Page of 6 7Dalmatian Fire 11/21/2019 Air Pressure Viking 25 1/4 53758759 Gauge Location Service Date 139 wet system 10/25/2019 Type Manufacturer Model #Static psi Fill Type Size OK ScanID TEST AN DRAIN 1011 55 53758756 Sprinkler Box Qty Tool Available?SIN List?Size Manufacturer Location OK ScanID 9 Yes 12 unit 139 53758766 Page of 7 7Dalmatian Fire 11/21/2019 Inventory & Warranty Report Generated by: BuildingReports.com Building: Baldwin Chamberss Bldg Pedcor - 61155 The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Device or Type Category % of Inventory Quantity Backflow Prevention Valve 15.00%3 Control Valve Valve 15.00%3 Waterflow Switch Alarm 5.00%1 Drain Device 10.00%2 Gauge Device 15.00%3 Dry Pipe Valve Valve 5.00%1 Pressure Switch Alarm 10.00%2 Air Compressor Pump 5.00%1 Sprinkler Box Sprinkler 5.00%1 Tamper Switch Alarm 5.00%1 Post Indicator Valve Valve 5.00%1 Fire Dep't Connection Hose 5.00%1 Device Type Qty Model #Type Description Install Date New (under 90 days) Wet Pipe Post Indicator Valve 1 AWWA Wall 10/25/2019 Sprinkler Box 1 10/25/2019 Air Compressor 1 S261R-LD1-115PD Automatic Tank 10/25/2019 Fire Dep't Connection 1 Storz 10/25/2019 Pressure Switch 1 PS10-2 Pressure Switch Alarm 10/25/2019 Pressure Switch 1 PS40-2 Low Supervisory 10/25/2019 Tamper Switch 1 PCVS-2 Lever Supervisory 10/25/2019 Waterflow Switch 1 VSR Vane Alarm 10/25/2019 Drain 1 Main 10/25/2019 Drain 1 1011 Combination 10/25/2019 Gauge 1 1011 10/25/2019 Control Valve 1 Butterfly Main Control 10/25/2019 Dry Pipe Valve 1 F-2 Grooved 10/25/2019 Gauge 1 Air Pressure 10/25/2019 Gauge 1 Supply Pressure 10/25/2019 Backflow Prevention 2 LF009M2QT Reduced Pressure 10/25/2019 Backflow Prevention 1 350A Double Check 10/25/2019 Control Valve 2 49 Butterfly Main Control 10/25/2019