HomeMy WebLinkAboutS102 - FLOOR FRAMING PLAN7'-6 1/2" 7'-6 1/2" 10"6'-7 1/4"6'-7 1/4" 7'-6 1/2" 7'-6 1/2" 10"
JOISTS @ 12" O.C.
UNDER FIREPLACE2X10 JOISTS @ 16" O.C. 2X10 JOISTS @ 16" O.C.
3 1/2" X 9 1/2" TREATED GLULAM
6X6 POST
NOTES:FLOOR FRAMING NOTES:
FURNISH & INSTALL (7) TREATED 6X6 POSTS
ON POST BASE ANCHORS AT NEW FOOTERS
AS SHOWN ON PLANS.
FURNISH & INSTALL 3 1/2" X 9 1/2" TREATED
GLULAM BEAMS AT NEW POSTS AS SHOWN ON
PLANS.
FURNISH & INSTALL TREATED 2X10 FLOOR
JOISTS @ 16" O.C. FOR NEW SUNROOM FLOOR
AS SHOWN ON PLANS. FLOOR JOISTS UNDER
FIREPLACE AREA TO BE 12" O.C. AS SHOWN
ON PLANS.
CONSTRUCTION
#0
ISSUE DATE:
2020-01-03
REV:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been prepared
by Case Design & Remodeling solely
for its use and should not be
reproduced or relied upon by any
other parties. Dimensions shown or
scaled are subject to change per
actual job condition and must be
verified. Materials are to be supplied
as specified as equal or standardwhen not uniquely specified. Installed
materials may vary in appearance
from drawings. Reference
manufacturer's product data for actual
appearance and specifications.IMLER RESIDENCE3-SEASON ROOM ADDITIONTIM & GERI IMLER708 NOTTINGHAM COURTCARMEL, INDIANA 46032Approved By:
Date:
S102
Jordan Stocklin
Designer
jstocklin@caseindy.com
Dawn Ashburn
Lead Designer
dashburn@caseindy.com
242590157
JOB NUMBER:
FLOOR FRAMING PLAN
SCALE: 3/8" = 1'
01/31/20
Adam Schriner