Loading...
HomeMy WebLinkAboutT202-SECOND-LEVEL-TECHNOLOGY-FLOOR-PLAN-Rev.4DNAVAVSSSSAUDAVAVCTLS SSSSSSAVAVSSCTLSSSS SSS SS SSSSSSSSSCTLCTLSAVCTLMCSSSSSDSAP3AP5AP5AP5AP3AP5AP5AP5AP3AP5AP5AP3AP3AP3AP5AP5AP5AP5AP5AP3AP4AP4AP5AP5AUDCTLAP5MONAP5SSS S SSSSS SS SS SS SSSSSSSSSSSSSAP3AP3AP4DSMEETING201LOBBY202ELEVATORLOBBY208STAIR #22ST2STAIR #12ST1COVEREDPORCH205STORAGE206CORRIDOR203VEST213REVENUE214LIBRARY210VEST215FURNITURESTORAGE217CORRIDOR247CATERING218F&B219VEST221MEN222WOMEN223JAN224RETAIL226WORK227VEST228SERV229WELCOMEDESK230F.O. MANAGER231LUGGAGE232BELL ACCESS233CORRIDOR234CORRIDOR235SERVICE236HOLDINGKITCHEN237WOMEN238MEN239COATS240STORAGE241PREFUNCTION242BREAKOUT243JAN245A/V ROOM244VESTIBULE204BOARDROOM211LOBBY BAR207MECHANICAL248CART STOR209CART STOR.216BALLROOM246CORRIDOR203204-AP207-AP210-AP214-AP203-AP2217-AP247-AP2247-AP1226-AP234-AP2234-AP1203-AP1208-AP242-AP2242-AP1237-AP242-AP3248-AP1249-AP2248-AP2246-AP1201-AP2201-AP1243-AP246-AP2UNISEX225249-AP1Z6Z6Z6Z6Z8Z8Z7Z7Z7Z7Z9Z9Z9Z9Z9Z9Z9Z9Z9Z9Z9Z9Z9Z9Z9Z9Z9Z11Z11Z11Z11Z11Z11Z10Z1090"Z6Z6Z6Z6Z6Z6Z6Z6PREFUNCTION242CORRIDOR20355"22"GM212CORR220Room200211-AP215-AP246-AP3TELECOM LEGENDWALL MOUNT ONT LOCATIONWIRELESS ACCESS POINT -WALL MOUNTEDREFER TO T400 FOR # INFORMATIONDIGITAL SIGNAGE LOCATIONTV/MONITOR LOCATIONAUDIO INPUT LOCATIONMOBILE CART LOCATIONMIXING LOCATIONAV INPUT LOCATIONAV INPUT LOCATION 2FITNESS ROOM TV LOCATIONAV FLOORBOX LOCATIONAV CONTROL LOCATIONTECHNICAL FACILITIES PANEL LOCATIONVOLUME CONTROL LOCATIONSPEAKER -CEILING MOUNTEDSPEAKER -WALL MOUNTEDAV CAMERA LOCATION -WALLAV CAMERA LOCATION -CEILINGSPKAP#SAVAVCTLONTMONDSCAMCAMAUDAVMCTFPMIXVCTV1. DIGITAL SIGNAGE LOCATION MOUNTED AT 6' TO CENTER AFF.2. DIGITAL SIGNAGE LOCATION MOUNTED AT 5' TO CENTER AFF.SHEET NOTESDRAWING NO.DATEGSB PROJECT NO.DRAWING TITLE3555 NW 58TH StreetSuite 700-WOklahoma City, OK 73112T: 405.848.9549F: 405.848.9783www.gsb-inc.comCopyright ©GSB, Inc ISSUED FOR CONSTRUCTION09/24/18T202SECOND LEVELTECHNOLOGY FLOOR PLAN171528CARMEL, INCARMEL, IN2018ARCHITECTGSB, INC3555 NW 58th Street, Suite 700WOklahoma City, OK 73112405 / 848-9549CIVIL ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 706-2075STRUCTURAL ENGINEERStructurePoint7260 Shadeland StationIndianapolis, IN 46256317 / 547-5580MEP ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 706-2075INTERIOR DESIGNERHBA Hirsch Bedner Associates171 17th Street NW, Suite 600Atlanta, GA 30363404 / 873-4379FOOD SERVICE CONSULTANTRicca Design Studios5325 South Valentia WayGreenwood Village, CO 80111303 / 928-1333 1/8" = 1'-0"1LEVEL 2 TECHNOLOGY FLOOR PLANGENERAL HORIZONTAL CABLING NOTESA MINIMUM CATEGORY 6 COMPLIANT 4-PAIR UNSHIELDEDTWISTED PAIR (UTP) . ALL HORIZONTAL CABLING MUSTBE PLENUM RATED.B MANUFACTURER CERTIFIED INCLUDING THE MINIMUMPERFORMANCE AND APPLICATIONS WARRANTY.C PAINTING OF THE STRUCTURED CABLING WILL VOIDTHE WARRANTY. ENSURE PROPER COORDINATIONWITH PAINTING CONTRACTOR SO THAT ALLSTRUCTURED CABLING IS PROTECTED PRIOR TO ANYPAINTING.D PROVIDE A MINIMUM 10 FOOT MAINTENANCE LOOP ONEACH HORIZONTAL CABLING RUN. MAINTENANCELOOPS SHALL BE STORED ABOVE ACCESIBLE CEILINGS,IN CABLE TRAY, AND IN TELECOMMUNICATION ROOMCABLE TRAY. CABLING ABOVE CEILING SHALL BESUSPENDED FROM APPROPRIATE SUPPORTS ANDSHALL NOT TOUCH THE CEILING.E ALL PIN/PAIR ASSIGNMENTS SHALL BE T568B.F CABLE JACKET COLOR SHALL BE AS REQUIRED BYSPECIFICATIONS.G LABELING SHALL BE COMPLETED AS DEFINED IN THECONTRACT DOCUMENTS AND SHALL BE COORDINATEDWITH THE OWNER.H PROVIDE ALL TELECOMMUNICATION OUTLETS ASSHOWN ON THE DRAWINGS AND AS REQUIRED TOPROVIDE CONNECTIONS FOR EACH DEVICE SHOWN ONTHE DRAWINGS.I ALL TESTING OF HORIZONTAL CABLING SHALL BECOMPLETED AS DIRECTED BY THE PROJECTSPECIFICATIONS. ALL CABLING MUST BE TESTED ANDCERTIFIED TO THE APPLICABLE STANDARDS.GENERAL PATHWAYS NOTESA ALL CABLING SHALL BE TERMINATED IN THE ER/TRNOTED IN THE TELECOM SCHEDULES.B CONTRACTOR SHALL SUPPLY ALL CONDUIT, BOXES,AND CABLE TRAY AS REQUIRED TO ENSURE ALLTRANSMISSION MEDIA IS FULLY SUPPORTED FROM ALLDEVICE LOCATIONS TO THE POINT OF TERMINATION.C ALL TELECOM PATHWAY SYSTEMS SHALL BEINDEPENDENTLY SUPPORTED FROM AND ATTACHED TOTHE BUILDING STRUCTURE.D ALL TELECOM PATHWAY SYSTEMS SHALL BECOMPLETELY AND PROPERLY LABELED AS REQUIREDIN REFERENCED STANDARDS.E CONDUIT SYSTEMS SHALL BE PROVIDED FOR ALLPATHWAYS IN INACCESSIBLE CEILING SPACES ANDWHERE EXPOSED TO PUBLIC VIEW. ALL CONDUITSYSTEMS THROUGHOUT THE BUILDING SHALL INCLUDEPROPERLY SIZED SLEEVED PENETRATIONS THROUGHALL BARRIERS.F ALL TELECOM OUTLET BOXES SHALL BE A MINIMUMDOUBLE GANG BOX NO LESS THAN 2 1/8" DEEP.G CORRIDOR SUPPORT SYSTEMS SHALL BE PROVIDED ASREQUIRED BY THE CONTRACT DRAWINGS. REFER TODIVISION 27 SPECIFICATIONS FOR ADDITIONALPRODUCT DETAILS AND REQUIREMENTS.H CONTRACTOR SHALL NOT EXCEED 40% FILL RATIOWITHIN ANY CONDUIT MEANT FORTELECOMMUNICATIONS CABLING.I CONTRACTOR SHALL CALCULATE FILL RATIOS BASEDON ACTUAL HORIZONTAL CABLING USED. TYPICAL FILLRATIOS FOR THE CABLE ARE SHOWN HERE FORREFERENCE PURPOSES ONLY:1" EMT = 6 CABLES;1¼" EMT = 11 CABLES;2" EMT = 24 CABLES;3" EMT = 64 CABLES;4" EMT = 107 CABLESJ CONDUIT RUNS SHALL NOT INCLUDE MORE THAN TWO90° BENDS BETWEEN PULLING POINTS. IF THE PATH OFTHE CONDUIT RUN REQUIRES BENDS EXCEEDING ATOTAL OF 180°, INSTALLATION OF AN APPROPRIATELYSIZED JUNCTION BOX IS REQUIRED WITHIN A STRAIGHTCONDUIT SECTION.K CONTRACTOR SHALL PROVIDE CONTINUOUSACCESSIBLE CONDUIT PATHWAY FOR ALL EXPOSEDDATA CABLING.L CONTRACTOR SHALL PROVIDE FIRE STOPS TO SEALALL PENETRATIONS THROUGH FLOORS, WALLS, STAIRS,AND ELEVATORS AS NECESSARY TO MEET CODEREQUIREMENTS. FIRE STOPS SHALL BE PROVIDED INACCORDANCE WITH ALL APPLICABLE CODES ANDSTANDARDS.M CONTRACTOR SHALL PROVIDE PROPERLY RATED FIRESTOP SYSTEMS FOR ALL CONDUIT AND/OR CABLE TRAYENTERING THE TELECOMMUNICATIONS ROOMS. EACHCONTRACTOR IS RESPONSIBLE FOR SEALINGPENETRATIONS AFTER EACH SCOPE OF WORK ISCOMPLETED.REVISIONSNO. DATE DESCRIPTION1 08/27/2018 Issued for construction2 09/12/2018 Addendum #23 09/20/2018 Addendum #44 06/07/2019 Revision #135 10/28/2019 Revision #1915255