HomeMy WebLinkAboutT203-THIRD-LEVEL-TECHNOLOGY-FLOOR-PLAN-Rev.4AP1TVAP1AP1AP1AP1AP1AP1AP 1 AP 1 AP 1 AP1AP 1 AP1AP1AP1AP1S S S S AP1AP 3 S TV TV TV TV TV TV CORRIDOR 301 CORRIDOR 302 CORRIDOR 303 STAIR #1 3ST1 STAIR #2 3ST2 ELEVATOR LOBBY 308 ELEC 306 HOUSEKEEPING 307 MECH 309 FITNESS 310 MECH 304 GUESTROOM KING STUDIO 310 GUESTROOM KING STUDIO 311 GUESTROOM QQ 314 GUESTROOM KING 313 GUESTROOM KING 316 GUESTROOM KING 318 GUESTROOM KING 319 GUESTROOM KING 320 GUESTROOM LUXURY SUITE A 321 GUESTROOM QQ W/ ADA COMM. 322 GUESTROOM KING 323 GUESTROOM KING 324 GUESTROOM KING 325 GUESTROOM KING 326 GUESTROOM KING 327 GUESTROOM KING 328 GUESTROOM KING 329 GUESTROOM KING 330 GUESTROOM KING 331 ADA GUESTROOM KING W/ ADA COMM. 332 GUESTROOM KING 333 GUESTROOM KING 334 GUESTROOM KING 335 GUESTROOM KING 336 GUESTROOM KING 337 GUESTROOM QQ W/BALCONY 338 GUESTROOM JUNIOR SUITE W/ ADA COMM. 339 GUESTROOM QQ 340 VEST 305 ADA GUESTROOM LUXURY SUITE B 312 340-AP 336-AP328-AP 325-AP 323-AP 312-AP1 310-AP 339-AP 332-AP 310-AP CORRIDOR 301 321-AP2 321-AP1 335-AP331-AP327-AP 313-AP 316-AP 319-AP TELECOM LEGEND WALL MOUNT ONT LOCATION WIRELESS ACCESS POINT -WALL MOUNTED REFER TO T400 FOR # INFORMATION DIGITAL SIGNAGE LOCATION TV/MONITOR LOCATION AUDIO INPUT LOCATION MOBILE CART LOCATION MIXING LOCATION AV INPUT LOCATION AV INPUT LOCATION 2 FITNESS ROOM TV LOCATION AV FLOORBOX LOCATION AV CONTROL LOCATION TECHNICAL FACILITIES PANEL LOCATION VOLUME CONTROL LOCATION SPEAKER -CEILING MOUNTED SPEAKER -WALL MOUNTED AV CAMERA LOCATION -WALL AV CAMERA LOCATION -CEILING SPK AP # S AV AV CTL ONT MON DS CAM CAM AUD AV MC TFP MIX VC TV 1. COAXIAL CONNECTIONS UTILIZING POKE-THRU'S FOR FITNESS ROOM EQUIPMENT 2. 46" DISPLAY MOUNTED AT 5'-6" AFF TO CENTER SHEET NOTES DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc ISSUED FOR CONSTRUCTION09/24/18 T203 THIRD LEVEL TECHNOLOGY FLOOR PLAN 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/8" = 1'-0"1 LEVEL 3 TECHNOLOGY FLOOR PLAN GENERAL HORIZONTAL CABLING NOTES A MINIMUM CATEGORY 6 COMPLIANT 4-PAIR UNSHIELDED TWISTED PAIR (UTP) . ALL HORIZONTAL CABLING MUST BE PLENUM RATED. B MANUFACTURER CERTIFIED INCLUDING THE MINIMUM PERFORMANCE AND APPLICATIONS WARRANTY. C PAINTING OF THE STRUCTURED CABLING WILL VOID THE WARRANTY. ENSURE PROPER COORDINATION WITH PAINTING CONTRACTOR SO THAT ALL STRUCTURED CABLING IS PROTECTED PRIOR TO ANY PAINTING. D PROVIDE A MINIMUM 10 FOOT MAINTENANCE LOOP ON EACH HORIZONTAL CABLING RUN. MAINTENANCE LOOPS SHALL BE STORED ABOVE ACCESIBLE CEILINGS, IN CABLE TRAY, AND IN TELECOMMUNICATION ROOM CABLE TRAY. CABLING ABOVE CEILING SHALL BE SUSPENDED FROM APPROPRIATE SUPPORTS AND SHALL NOT TOUCH THE CEILING. E ALL PIN/PAIR ASSIGNMENTS SHALL BE T568B. F CABLE JACKET COLOR SHALL BE AS REQUIRED BY SPECIFICATIONS. G LABELING SHALL BE COMPLETED AS DEFINED IN THE CONTRACT DOCUMENTS AND SHALL BE COORDINATED WITH THE OWNER. H PROVIDE ALL TELECOMMUNICATION OUTLETS AS SHOWN ON THE DRAWINGS AND AS REQUIRED TO PROVIDE CONNECTIONS FOR EACH DEVICE SHOWN ON THE DRAWINGS. I ALL TESTING OF HORIZONTAL CABLING SHALL BE COMPLETED AS DIRECTED BY THE PROJECT SPECIFICATIONS. ALL CABLING MUST BE TESTED AND CERTIFIED TO THE APPLICABLE STANDARDS. GENERAL PATHWAYS NOTES A ALL CABLING SHALL BE TERMINATED IN THE ER/TR NOTED IN THE TELECOM SCHEDULES. B CONTRACTOR SHALL SUPPLY ALL CONDUIT, BOXES, AND CABLE TRAY AS REQUIRED TO ENSURE ALL TRANSMISSION MEDIA IS FULLY SUPPORTED FROM ALL DEVICE LOCATIONS TO THE POINT OF TERMINATION. C ALL TELECOM PATHWAY SYSTEMS SHALL BE INDEPENDENTLY SUPPORTED FROM AND ATTACHED TO THE BUILDING STRUCTURE. D ALL TELECOM PATHWAY SYSTEMS SHALL BE COMPLETELY AND PROPERLY LABELED AS REQUIRED IN REFERENCED STANDARDS. E CONDUIT SYSTEMS SHALL BE PROVIDED FOR ALL PATHWAYS IN INACCESSIBLE CEILING SPACES AND WHERE EXPOSED TO PUBLIC VIEW. ALL CONDUIT SYSTEMS THROUGHOUT THE BUILDING SHALL INCLUDE PROPERLY SIZED SLEEVED PENETRATIONS THROUGH ALL BARRIERS. F ALL TELECOM OUTLET BOXES SHALL BE A MINIMUM DOUBLE GANG BOX NO LESS THAN 2 1/8" DEEP. G CORRIDOR SUPPORT SYSTEMS SHALL BE PROVIDED AS REQUIRED BY THE CONTRACT DRAWINGS. REFER TO DIVISION 27 SPECIFICATIONS FOR ADDITIONAL PRODUCT DETAILS AND REQUIREMENTS. H CONTRACTOR SHALL NOT EXCEED 40% FILL RATIO WITHIN ANY CONDUIT MEANT FOR TELECOMMUNICATIONS CABLING. I CONTRACTOR SHALL CALCULATE FILL RATIOS BASED ON ACTUAL HORIZONTAL CABLING USED. TYPICAL FILL RATIOS FOR THE CABLE ARE SHOWN HERE FOR REFERENCE PURPOSES ONLY: 1" EMT = 6 CABLES; 1¼" EMT = 11 CABLES; 2" EMT = 24 CABLES; 3" EMT = 64 CABLES; 4" EMT = 107 CABLES J CONDUIT RUNS SHALL NOT INCLUDE MORE THAN TWO 90° BENDS BETWEEN PULLING POINTS. IF THE PATH OF THE CONDUIT RUN REQUIRES BENDS EXCEEDING A TOTAL OF 180°, INSTALLATION OF AN APPROPRIATELY SIZED JUNCTION BOX IS REQUIRED WITHIN A STRAIGHT CONDUIT SECTION. K CONTRACTOR SHALL PROVIDE CONTINUOUS ACCESSIBLE CONDUIT PATHWAY FOR ALL EXPOSED DATA CABLING. L CONTRACTOR SHALL PROVIDE FIRE STOPS TO SEAL ALL PENETRATIONS THROUGH FLOORS, WALLS, STAIRS, AND ELEVATORS AS NECESSARY TO MEET CODE REQUIREMENTS. FIRE STOPS SHALL BE PROVIDED IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. M CONTRACTOR SHALL PROVIDE PROPERLY RATED FIRE STOP SYSTEMS FOR ALL CONDUIT AND/OR CABLE TRAY ENTERING THE TELECOMMUNICATIONS ROOMS. EACH CONTRACTOR IS RESPONSIBLE FOR SEALING PENETRATIONS AFTER EACH SCOPE OF WORK IS COMPLETED. REVISIONS NO. DATE DESCRIPTION 1 08/27/2018 Issued for construction 2 06/07/2019 Revision #13 3 08/02/2019 Revision #15 4 9/26/2019 RFI-155 1 1 RFI-155 RFI-155 2 RFI-155