Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T206-SIXTH-LEVEL-TECHNOLOGY-FLOOR-PLAN-Rev.3
AP1AP1AP1AP1AP1AP1AP1AP 1 AP 1 AP 1 AP1AP 1 AP1AP1AP1AP1AP 1 AP 3 STAIR #1 6ST1 STAIR #2 6ST2 CORRIDOR 601 CORRIDOR 602 MECH 604 VEST 605 ELEC 606 ELEVATOR LOBBY 608 HOUSEKEEPING 607 GUESTROOM KING STUDIO 610 GUESTROOM KING 613 GUESTROOM KING 614 GUESTROOM KING 615 GUESTROOM KING W/ ADA COMM. 617 GUESTROOM KING 620 GUESTROOM KING 624 GUESTROOM KING 632 GUESTROOM KING 634 GUESTROOM KING STUDIO 611 ADA COMM. GUESTROOM LUXURY SUITE B 612 CORRIDOR 603 GUESTROOM KING 619 GUESTROOM KING 616 GUESTROOM KING 623 GUESTROOM QQ 622 ADA GUESTROOM LUXURY SUITE A 621 GUESTROOM KING 618 GUESTROOM KING 625 GUESTROOM KING 626 GUESTROOM QQ 628 GUESTROOM KING 630 GUESTROOM KING 636 GUESTROOM QQ W/BALCONY 638 GUESTROOM QQ W/ ADA COMM. 640 GUESTROOM JUNIOR SUITE 639GUESTROOM KING 637 GUESTROOM KING 635 GUESTROOM KING 633 GUESTROOM KING 631 GUESTROOM KING 629 GUESTROOM KING 627 ? ? 620-AP 614-AP 612-AP 629-AP 633-AP 637-AP 618-AP 608-AP T300 3 621-AP1 621-AP2 622-AP 624-AP 626-AP 630-AP 634-AP 638-AP 611-AP TELECOM LEGEND WALL MOUNT ONT LOCATION WIRELESS ACCESS POINT -WALL MOUNTED REFER TO T400 FOR # INFORMATION DIGITAL SIGNAGE LOCATION TV/MONITOR LOCATION AUDIO INPUT LOCATION MOBILE CART LOCATION MIXING LOCATION AV INPUT LOCATION AV INPUT LOCATION 2 FITNESS ROOM TV LOCATION AV FLOORBOX LOCATION AV CONTROL LOCATION TECHNICAL FACILITIES PANEL LOCATION VOLUME CONTROL LOCATION SPEAKER -CEILING MOUNTED SPEAKER -WALL MOUNTED AV CAMERA LOCATION -WALL AV CAMERA LOCATION -CEILING SPK AP # S AV AV CTL ONT MON DS CAM CAM AUD AV MC TFP MIX VC TV DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc ISSUED FOR CONSTRUCTION09/24/18 T206 SIXTH LEVEL TECHNOLOGY FLOOR PLAN 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/8" = 1'-0"1 LEVEL 6 TECHNOLOGY FLOOR PLAN GENERAL HORIZONTAL CABLING NOTES A MINIMUM CATEGORY 6 COMPLIANT 4-PAIR UNSHIELDED TWISTED PAIR (UTP) . ALL HORIZONTAL CABLING MUST BE PLENUM RATED. B MANUFACTURER CERTIFIED INCLUDING THE MINIMUM PERFORMANCE AND APPLICATIONS WARRANTY. C PAINTING OF THE STRUCTURED CABLING WILL VOID THE WARRANTY. ENSURE PROPER COORDINATION WITH PAINTING CONTRACTOR SO THAT ALL STRUCTURED CABLING IS PROTECTED PRIOR TO ANY PAINTING. D PROVIDE A MINIMUM 10 FOOT MAINTENANCE LOOP ON EACH HORIZONTAL CABLING RUN. MAINTENANCE LOOPS SHALL BE STORED ABOVE ACCESIBLE CEILINGS, IN CABLE TRAY, AND IN TELECOMMUNICATION ROOM CABLE TRAY. CABLING ABOVE CEILING SHALL BE SUSPENDED FROM APPROPRIATE SUPPORTS AND SHALL NOT TOUCH THE CEILING. E ALL PIN/PAIR ASSIGNMENTS SHALL BE T568B. F CABLE JACKET COLOR SHALL BE AS REQUIRED BY SPECIFICATIONS. G LABELING SHALL BE COMPLETED AS DEFINED IN THE CONTRACT DOCUMENTS AND SHALL BE COORDINATED WITH THE OWNER. H PROVIDE ALL TELECOMMUNICATION OUTLETS AS SHOWN ON THE DRAWINGS AND AS REQUIRED TO PROVIDE CONNECTIONS FOR EACH DEVICE SHOWN ON THE DRAWINGS. I ALL TESTING OF HORIZONTAL CABLING SHALL BE COMPLETED AS DIRECTED BY THE PROJECT SPECIFICATIONS. ALL CABLING MUST BE TESTED AND CERTIFIED TO THE APPLICABLE STANDARDS. GENERAL PATHWAYS NOTES A ALL CABLING SHALL BE TERMINATED IN THE ER/TR NOTED IN THE TELECOM SCHEDULES. B CONTRACTOR SHALL SUPPLY ALL CONDUIT, BOXES, AND CABLE TRAY AS REQUIRED TO ENSURE ALL TRANSMISSION MEDIA IS FULLY SUPPORTED FROM ALL DEVICE LOCATIONS TO THE POINT OF TERMINATION. C ALL TELECOM PATHWAY SYSTEMS SHALL BE INDEPENDENTLY SUPPORTED FROM AND ATTACHED TO THE BUILDING STRUCTURE. D ALL TELECOM PATHWAY SYSTEMS SHALL BE COMPLETELY AND PROPERLY LABELED AS REQUIRED IN REFERENCED STANDARDS. E CONDUIT SYSTEMS SHALL BE PROVIDED FOR ALL PATHWAYS IN INACCESSIBLE CEILING SPACES AND WHERE EXPOSED TO PUBLIC VIEW. ALL CONDUIT SYSTEMS THROUGHOUT THE BUILDING SHALL INCLUDE PROPERLY SIZED SLEEVED PENETRATIONS THROUGH ALL BARRIERS. F ALL TELECOM OUTLET BOXES SHALL BE A MINIMUM DOUBLE GANG BOX NO LESS THAN 2 1/8" DEEP. G CORRIDOR SUPPORT SYSTEMS SHALL BE PROVIDED AS REQUIRED BY THE CONTRACT DRAWINGS. REFER TO DIVISION 27 SPECIFICATIONS FOR ADDITIONAL PRODUCT DETAILS AND REQUIREMENTS. H CONTRACTOR SHALL NOT EXCEED 40% FILL RATIO WITHIN ANY CONDUIT MEANT FOR TELECOMMUNICATIONS CABLING. I CONTRACTOR SHALL CALCULATE FILL RATIOS BASED ON ACTUAL HORIZONTAL CABLING USED. TYPICAL FILL RATIOS FOR THE CABLE ARE SHOWN HERE FOR REFERENCE PURPOSES ONLY: 1" EMT = 6 CABLES; 1¼" EMT = 11 CABLES; 2" EMT = 24 CABLES; 3" EMT = 64 CABLES; 4" EMT = 107 CABLES J CONDUIT RUNS SHALL NOT INCLUDE MORE THAN TWO 90° BENDS BETWEEN PULLING POINTS. IF THE PATH OF THE CONDUIT RUN REQUIRES BENDS EXCEEDING A TOTAL OF 180°, INSTALLATION OF AN APPROPRIATELY SIZED JUNCTION BOX IS REQUIRED WITHIN A STRAIGHT CONDUIT SECTION. K CONTRACTOR SHALL PROVIDE CONTINUOUS ACCESSIBLE CONDUIT PATHWAY FOR ALL EXPOSED DATA CABLING. L CONTRACTOR SHALL PROVIDE FIRE STOPS TO SEAL ALL PENETRATIONS THROUGH FLOORS, WALLS, STAIRS, AND ELEVATORS AS NECESSARY TO MEET CODE REQUIREMENTS. FIRE STOPS SHALL BE PROVIDED IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. M CONTRACTOR SHALL PROVIDE PROPERLY RATED FIRE STOP SYSTEMS FOR ALL CONDUIT AND/OR CABLE TRAY ENTERING THE TELECOMMUNICATIONS ROOMS. EACH CONTRACTOR IS RESPONSIBLE FOR SEALING PENETRATIONS AFTER EACH SCOPE OF WORK IS COMPLETED. REVISIONS NO. DATE DESCRIPTION 1 08/27/2018 Issued for construction 2 06/07/2019 Revision #13 3 08/02/2019 Revision #15 3 3 3