Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A5-25-ROOF-DETAILS-Rev.4
ROOF DRAIN SINGLE PLY ROOFING MEMBRANE DRAIN PIPE CL AUX. DRAIN -SET INLET 2" ABOVE PRIMARY ROOF DRAIN 1/4" SLOPE . 1/2" SLOPE MIN . PRECAST CONCRETE DECK -ORIENTATION VARIESEDGE OFSUMP1/2" SLOPE MIN 2' - 0"2' - 0"4"3"LAP SEALANT ROOF INSULATION COVER BOARDEDGE OFSUMP1/4" SLOPE DRAIN PIPE FIRESTOP SYSTEM FIRESTOP SYSTEM SINGLE PLY ROOFING MEMBRANE ON COVER BD. PRECAST CONCRETE DECK - ORIENTATION VARIES TAPERED INSUL. ROOFING MEMBRANE FLASHING WITH S.S. CLAMP. SEAL EDGE W/ SEALANT 24 GA. S.S. SKIRT FLASHING W/ S.S. CLAMP 3" EXTRA STRONG GALV. PIPE @ 6'-0" 0.C. MAX 1' - 0"MECH. EQUIPMENT WITH ISOLATOR PAD CONT. 4X3X5/16 STEEL ANGLE 6" 10X10X1/2" STEEL PLATE W/ (4) LG. HEADED STUDS @ 6'-0" O.C. MAX URETHANE SEALANT 5X5X3/8" STEEL PLATE 3 A5-25 2' - 0" 4' - 0"4' - 0"EQ EQ EQEQAUX. DRAIN ROOF DRAIN 1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12" ROOF SUMP SINGLE PLY ROOFING MEMBRANE ON COVER BD. PRECAST CONCRETE DECK - ORIENTATION VARIES TAPERED INSULATION SINGLE-PLY ROOFING MEMBRANE FLASHING WITH S.S. CLAMP. SEAL EDGE W/ SEALANT 24 GA. S.S. SKIRT FLASHING W/ S.S. CLAMP VENT PIPE 6" URETHANE SEALANT FIRESTOP SYSTEM PLAN VIEW FRONT VIEW SIDE VIEW2' - 6"1' - 6"DIRECTION OF FLOW4"1"1"4"HOT-DIP GALVANIZED SHEET METAL PAN WITH CORRUGATED BOTTOM COPING CAP AND EDGE FLASHING, PREFINISHED PREFINISHED COPING CAP COVER AT JOINT APPLY CONTINUOUS BEAD OF SEALANT TO EACH SIDE, AND WIPE CLEAN ANY EXCESS 8 "E Q E Q PRECAST CONCRETE DECK - ORIENTATION VARIES PREFABRICATED, INSULATING CURB ASSEMBLY MECHANICAL EQUIPMENT EXTEND ROOFING MEMBRANE FLASHING SHEET UP AND OVER TOP OF CURB NAILER SINGLE-PLY ROOFING MEMBRANE FLASHING CURB FASTENER AS REQUIRED SINGLE-PLY ROOFING MEM- BRANE ON COVER BOARD ON ROOF INSULATION LINE OF DUCTWORK NOTE: DUCT WRAP: EXHAUST DUCTS TO BE COVERED WITH AN APPROVED 1-HOUR RATED MINERAL "FIRE WRAP". PRE-FIN ALUMINUM 2-PIECE COUNTER FLASHING & RECEIVER TOP OF CONC. SLAB 84' - 8"6"1" MIN.8 1/2"10 A5-25 9 A5-25 SINGLE-PLY ROOFING MEMBRANE 1' - 0" PREFINISHED METAL CONDUCTOR HEAD PREFINISHED METAL STRAP PREFINISHED METAL DOWNSPOUT PREFINISHED METAL SCUPPER SINGLE-PLY ROOFING SYSTEM ON PROTECTION BOARD TAPERED INSULATION METAL DECK ON STEEL STRUCTURE BATT INSULATION A5-25 13 SLOPE TOP OF CONC. SLAB 84' - 8" 11 A5-25 9 A5-25 8 1/2"1"6"2"2"1' - 0"2" SEALANT AT FLANGE -TOP AND SIDES CONDUCTOR HEAD DOWNSPOUT DOWNSPOUT STRAP SCUPPER 11 A5-25 10 A5-251/4" / 12"1/4" / 12"1/4" / 12" 1' - 11 1/4"1' - 0"1' - 0" EQ EQ CONDUCTOR HEAD DOWNSPOUT BELOW E.I.F.S. OVER SHEATHING DETAIL SINGLE-PLY ROOFING MEMBRANE SHEATHING METAL SCUPPER ASSEMBLY CONTINUOUS SEALANT -TOP AND SIDES HEM METAL AT PERIMETER OF SCUPPER OPENING EIFS WEATHER BARRIER SHEATHING WALL FRAMING SINGLE-PLY ROOFING MEMBRANE SHIM DETAIL SINGLE-PLY ROOFING MEMBRANE WRAPS INTO OPENING-SEAL SHEATHING METAL SCUPPER ASSEMBLY CONTINUOUS SEALANT -TOP AND SIDES HEM METAL AT PERIMETER OF SCUPPER OPENING EIFS WEATHER BARRIER SHEATHING WALL FRAMING SELF-ADHERED MEMBRANE SINGLE-PLY ROOFING MEMBRANE SHEATHING WALL FRAMING PREFINISHED METAL SCUPPER 2x WOOD NAILER TIE BACK ANCHOR -WELD DOWN TO EMBED PLATE CONTINUOUS SEALANT AT PERIMETER STAINLESS STEEL DRAWBAND CLAMP BOOT FLASHING ROOF MEMBRANE COVER BOARD ROOF INSULATION PRECAST CONCRETE DECK - ORIENTATION VARIES 1' - 6"POURABLE SEALER PREFAB COLUMN CURB AS MFR'D. BY CHEMLINK OR APPROVED SUBSTITUTE. INSTALLED IN ACCORDANCE w/ MFR RECOMMENDATIONS STRUCTURAL SEALANT ON STRUCTURE & ROOF MEMBRANE THREADED TENSION ROD & CLEVIS, COATED w/ INTUMESCENT PAINT - 2-hr RATED GALV. MOUNTING PLATE MTL ROOF DECK STRUCTURAL STEEL BEAM w/ SPRAY APPLIED FIREPROOFING - 2-hr RATED PROTECTION BOARD ROOF MEMBRANE TAPERED RIGID INSULATION BUT DUE TO SLOPED PENETRATION MAKE A WORKABLE DIM. TO MAINTAIN QUALITY INSTALL 1" MIN. PER MFR,1' - 1" MIN.20 DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc A5-25 09/12/18 ROOF DETAILS 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION 1 1/2" = 1'-0"A5-25 3 ROOF DRAIN DETAIL 3" = 1'-0"A5-25 5 ROOFTOP EQUIPMENT SUPPORT DETAIL 3/4" = 1'-0"A5-25 2 PLAN DETAIL - ROOF DRAIN 3" = 1'-0"A5-25 6 VENT PIPE DETAIL 1 1/2" = 1'-0"A5-25 8 SPLASH PAN 1 1/2" = 1'-0"A5-25 4 METAL COPING DETAIL ISOMETRIC 1 1/2" = 1'-0"A5-25 7 SECTION AT ROOF CURB 1 1/2" = 1'-0"A5-25 11 SECTION THROUGH SCUPPER 1 1/2" = 1'-0"A5-25 10 SCUPPER ELEVATION 1 1/2" = 1'-0"A5-25 9 SCUPPER PLAN 3" = 1'-0"A5-25 13 SECTION THROUGH SCUPPER - DETAIL 1 1/2" = 1'-0"A5-25 1 ROOF ANCHOR DETAIL 3 ADD #2 3" = 1'-0"A5-25 14 ROOF CURB AT MOUNT PLATE PENETRATION 1120 NO. DATE DESCRIPTION 3 12/03/2018 General Revisions 11 05/29/2019 General Revisions 20 11/06/2019 General Revisions