HomeMy WebLinkAboutA6-03-PARTITION-TYPES-Rev.5GENERAL PARTITION NOTES 1. HOLD GWB UP OFF OF THE SLAB 1/4" MIN. FOR ALL WALLS UNLESS OTHERWISE NOTED. 2. FOR SEALANT TYPE AND LOCATION REFER TO SEALANT SCHEDULE IN SPECIFICATIONS ON 07 92 00 -7. 3. REFER TO ROOM FINISH FOR FLOOR FINISH, BASE MATERIAL, WALL FINISH & CEILING MATERIAL. 4. WHERE PARTITIONS EXTEND TO STRUCTURAL DECK OR FLOOR SLAB SCRIBE, FIT & SEAL PARTITION TO THESE STRUCTURAL ELEMENTS AND ALL AROUND PENETRATING MEMBERS TO ACHIEVE A SMOKE AND SOUND TIGHT CONDITION. COMPLY W/ REFERENCED U.L. DESIGNS TO MEET INDICATED FIRE RATINGS. 5. SOUND TESTING AGENCIES SPECIFIED ON PARTITION TYPE TITLES: • SA -SHINER & ASSOCIATES • USG -UNITED STATES GYPSUM COMPANY 6. PROVIDE ACOUSTICAL RATED PARTITIONS AND WALLS IN ACCORDANCE WITH THE TESTED ASSEMBLY DESIGN AS INDICATED ON THIS SHEET. INCLUDE ALL COMPONENTS WHETHER OR NOT INDICATED ON THE DETAILS. 7. CONTRACTOR IS TO COORDINATE WITH ALL SUBCONTRACTORS TO ENSURE THAT ALL OPENINGS FOR PENETRATIONS THROUGH ACOUSTICALLY RATED WALLS ARE CUT TIGHT TO DUCTWORK CONDUIT. OTHER PENETRATING MEMBERS AND ALL GAPS ARE TO BE COMPLETELY SEALED TO ACHIEVE A SMOKE AND SOUND TIGHT CONDITION ON BOTH SIDES OF THE PARTITION. 8. GUESTROOM BATHS: ALL... SHOWER WALLS AND TUB SURROUNDS TO BE CONSTRUCTED OF CEMENTITIOUS TILE BACKERBOARD. THE REMAINING WET-ROOM WALLS TO BE CONSTRUCTED OF 1/2" MR GYP. BD. REFER TO PLANS AND PARTITION TYPES FOR LOCATIONS. 9. PUBLIC & BOH RESTROOMS: INSTALL 5/8" MR GYPSUM BD ON WALLS AND 5/8" ON FRAMING @ 16 O.C. ON CEILINGS, EXCEPT AT SHOWER WALLS. INSTALL 1/2" CEMENTITIOUS BACKERBOARD AT SHOWER WALLS. 10. ALL WALLS TO RECEIVE TILE FINISH TO HAVE 20 GA STUD FRAMING AT 16" O.C. MAX. 11. SEAL ALL HORIZONTAL AND VERTICAL CHANGE OF DIRECTION JOINTS IN WALL TILE (TYP.) 12. PROVIDE CONCEALED ANCHOR PLATE SUPPORT FOR GRAB BAR AND TOILET ACCESSORIES ATTACHMENT, AS REQUIRED BY EACH MANUFACTURER. 13. ALL GYPSUM BD. THAT IS WET OR SHOWING SIGNS OF MOLD & MILDEW SHALL BE REMOVED. 14. ALL GYPSUM BD. THAT IS WET OR SHOWING SIGNS OF MOLD AND MILDEW SHALL BE REMOVED. 15. UNLESS OTHERWISE NOTED, ALL STUDS TO BE 25 GA. BASIC MATERIAL: C CONCRETE M MASONRY (CMU) S STUD BASIC SIZE: 0 7/8" FURRING CHANNEL 1 1 5/8" STUD 2 2 1/2" STUD 3 3 5/8" STUD 4 4" CONCRETE, MASONRY OR STUD 6 6" CONCRETE, MASONRY OR STUD 8 8" CONCRETE, MASONRY OR STUD APPLIED LAYERS: A 1 LAYER 5/8" GYPSUM BOARD B 2 LAYERS 5/8" GYPSUM BOARD C 1 LAYERS 1/2" GYPSUM BOARD D 2 LAYERS 1/2" GYPSUM BOARD E AIR CAVITY F 1 LAYER 5/8" CEMENTITIOUS BACKER BOARD G 1 LAYER 1/2" CEMENTITIOUS BACKER BOARD H 1 LAYER 5/8" MOISTURE RESISTANT GYPSUM BOARD J 1 LAYER 1/2" MOISTURE RESISTANT GYPSUM BOARD K SHAFTWALL CONSTRUCTION L 3 LAYERS 5/8" GYPSUM BOARD MODIFYING CONDITIONS: 1. STC RATED ASSEMBLY. 2. FIRE RATED ASSEMBLY. 3. FIRE RATED ASSEMBLY AND STC RATED ASSEMBLY. 4. SPECIAL FIRE RATED ASSEMBLY AND STC RATED ASSEMBLY. PARTITION TYPE SYMBOL BASIC MATERIAL BASIC SIZE APPLIED LAYERS CODE MODIFYING CONDITIONS CODE M8C.1 PARTITION TYPE LEGEND M8CC.1 1 LETTER = LAYER ON ONE SIDE 2 LETTERS = LAYER ON EACH SIDE CONC. SLAB BOTTOM OF STRUCTURAL DECK CEILING, AS SCHED. RE: REFLECTED CLG. PLANS WALL BASE, AS SCHED M8.2 INTERIOR PARTITION 1 HR RATED NON-LOAD BEARING 8" CMU - CONC. SLAB BOTTOM OF STRUCTURAL DECK CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS WALL BASE, AS SCHEDULED M4 MASONRY WALL NON-RATED NON-LOAD BEARING 4" CMU (2) LAYERS 5/8" GYP. BD. EA. SIDE ON 25 GA. 6" MTL. STUDS @ 24" O.C. CONC. SLAB WALL BASE, AS SCHEDULED BOTTOM OF STRUCTURAL DECK CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS8 1/2" S6BB.1 INTERIOR PARTITION - STC NON-RATED NON-LOAD BEARING STC 57 NRCC 818-NV, 2-3-81 S6BB.2 INTERIOR PARTITION - FIRE RATED 2 HR RATED CONSTR. (1 HR REQ'D) NON-LOAD BEARING UL U411; WP 1548 S6BB.3 INTERIOR PARTITION - STC & FIRE RATED 2 HR RATED CONSTR. (1 HR REQ'D) NON-LOAD BEARING UL U411; WP 1548 STC 57 NRCC 818-NV, 2-3-81 5/8" GYP. BD. EA. SIDE ON 25 GA. 6" MTL. STUDS @ 24" O.C. CONC. SLAB WALL BASE, AS SCHEDULED BOTTOM OF STRUCTURAL DECK EXTEND STUDS & GYP. BD. TO STRUCTURE @ LOCATIONS W/O SUSP. CLG. CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS6"8 5/8" S6BB INTERIOR PARTITION NON-RATED NON-LOAD BEARING 3 1/2" SOUND INSULATION @ SOUND RATED PARTITIONS (2) LAYERS 5/8" GYP. BD. ON 25 GA. 6" MTL. STUDS @ 24" O.C. CONC. SLAB WALL BASE, AS SCHEDULED BOTTOM OF STRUCTURAL DECK CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS 8 1/4" S6BD.2 INTERIOR PARTITION - FIRE RATED 2 HR RATED CONSTR. (1 HR REQ'D) NON-LOAD BEARING UL U411; WP 1548 3 1/2" SOUND INSULATION @ SOUND RATED PARTITIONS (2) LAYERS 1/2" GYP. BD. 5/8" GYP. BD. EA. SIDE ON 25 GA. 6" MTL. STUDS @ 24" O.C. CONC. SLAB WALL BASE, AS SCHEDULED BOTTOM OF STRUCTURAL DECK CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS7 1/4" CONC. SLAB WALL BASE, AS SCHEDULED CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS SOUND INSULATION S6AA.1 INTERIOR PARTITION - STC NON-RATED NON-LOAD BEARING STC 47 NRCC 816-NV, 2-3-81 S6AA.2 INTERIOR PARTITION - FIRE RATED 1 HR RATED NON-LOAD BEARING WP 1350 S6AA.3 INTERIOR PARTITION - STC & FIRE RATED 1 HR RATED NON-LOAD BEARING WP 1350 STC 47 NRCC 816-NV, 2-3-81 5/8" GYP. BD. EA. SIDE ON 25 GA. 6" MTL. STUDS @ 24" O.C. CONC. SLAB WALL BASE, AS SCHEDULED BOTTOM OF STRUCTURAL DECK EXTEND STUDS & GYP. BD. TO STRUCTURE @ LOCATIONS W/O SUSP. CLG. CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS6"7 1/4" CONC. SLAB WALL BASE, AS SCHEDULED CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS S6AA INTERIOR PARTITION NON-RATED NON-LOAD BEARING (2) LAYERS 5/8" GYP. BD. CONC. SLAB WALL BASE, AS SCHEDULED BOTTOM OF STRUCTURAL DECK CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS 9 1/4" CONC. SLAB WALL BASE, AS SCHEDULED CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS 5 1/2" INSULATION S6BL.3 INTERIOR PARTITION - STC & FIRE RATED 2 HR RATED CONSTR. (1 HR REQ'D) NON-LOAD BEARING UL U411; WP 1548 STC 57 NRCC 818-NV, 2-3-81 (3) LAYERS 5/8" GYP. BD. ON 25 GA. 6" MTL. STUDS @ 24" O.C. CONC. SLAB WALL BASE, AS SCHEDULED BOTTOM OF STRUCTURAL DECK CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS CONC. SLAB WALL BASE, AS SCHEDULED CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS 7 1/2" INSULATION S8BB.1 INTERIOR PARTITION - STC & FIRE RATED NON-RATED NON-LOAD BEARING STC 57 NRCC 818-NV, 2-3-81 (2) LAYERS 5/8" GYP. BD. ON 25 GA. 8" MTL. STUDS @ 24" O.C. 5/8" GYP. BD. ON 25 GA. 6" MTL. STUDS @ 24" O.C. FUR STUDS OUT FROM CONC. OR CMU TO MAINTAIN A PLUMB FINISH. WHERE APPLICABLE. CONC. SLAB WALL BASE, AS SCHEDULED BOTTOM OF STRUCTURAL DECK EXTEND STUDS & GYP. BD. TO STRUCTURE @ LOCATIONS W/O SUSP. CLG. CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS6"S6A INTERIOR PARTITION NON-RATED NON-LOAD BEARING 6 5/8" 3 3 ADD #2 ADD #2 FULLY GROUTED AT FEINSTEIN CLUB (2) LAYERS OF 5/8" GYP. BD. ON 25 GA. 6" MTL. STUDS @ 24" O.C. FUR STUDS OUT FROM CONC. OR CMU TO MAINTAIN A PLUMB FINISH. WHERE APPLICABLE. CONC. SLAB WALL BASE, AS SCHEDULED BOTTOM OF STRUCTURAL DECK EXTEND STUDS & GYP. BD. TO STRUCTURE @ LOCATIONS W/O SUSP. CLG. & AT FEINSTEIN CLUB CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS6"S6B INTERIOR PARTITION NON-RATED NON-LOAD BEARING 7 1/4" AT FEINSTEIN CLUB: 3 1/2" FACED ACOUSTIC BATTS STAPLED TO STUDS 3 ADD #5 3 ADD #5 (2) LAYERS 1/2" GYP. BD. ON 25 GA. 3 5/8" MTL. STUDS @ 24 O.C. CONC. SLAB WALL BASE, AS SCHEDULED BOTTOM OF STRUCTURAL DECK CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS8 3/4"S8CD.3 INT PARTITION - CORRIDOR 1 HR RATED NON-LOAD BEARING UL U453 STC 50 SA-800504 CONC. SLAB WALL BASE, AS SCHEDULED CEILING, AS SCHEDULED RE: REFLECTED CLG. PLANS 9 1/2" 1/2" GYP. BD. 3 1/2" FACED SOUND INSULATION STAPLED TO STUDS 20 RFI #139 DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc A6-03 08/27/18 PARTITION TYPES 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION3 ADD #2 NO. DATE DESCRIPTION 1 08/27/2018 Issued for construction 3 12/03/2018 General Revisions 20 11/06/2019 General Revisions