Loading...
HomeMy WebLinkAboutA6-20-INTERIOR-DETAILS-Rev.5LEVEL 3 32' - 0" 7 6" MIN.ACOUST. ISO. CLG 14'-5" AFF FINISH CLG 12'-4" AFF FURR DOWN 11'-4" AFF MIN1/2".COMBO SPRING / NEOPRENE HANGERS - MASON TYPE 30N (1" DEFLECTION) SUSP. GYP BD CEILING (2) LAYERS OF 5/8" GWB ON 3 5/8" MTL STUDS @ 24" O.C. (2) LAYERS OF 5/8" GWB ON 7/8" HAT CHANNELS @ 24" O.C., ON 2 1/2" MTL STUDS @ 24" O.C.3" SAFB, TYP. STRUCTURAL BEAM w/ SPRAY APPLIED CEMENTITIOUS FIRE PROOFING (2/HR RATED) STRUCTURAL SLAB & CONC TOPPING SLAB 1' - 2"1' - 2" CORNICE TRIM - REF. I.D. 1' - 0"3 ADD #2 LEVEL 3 32' - 0" ACOUST. ISO. CLG 14'-5" AFF FINISH CLG 12'-4" AFF SUSP. GYP BD CEILING (2) LAYERS OF 5/8" GWB ON 7/8" HAT CHANNELS @ 24" O.C., ON 2 1/2" MTL STUDS @ 24" O.C. COMBO SPRING / NEOPRENE HANGERS - MASON TYPE 30N (1" DEFLECTION) 3" SAFB, TYP6" MINSTRUCTURAL SLAB & CONC TOPPING SLAB LEVEL 2 16' - 0" 25 FINISH CLG 11'-0" AFF SUSP. GYP BD CEILING (2) LAYERS OF 5/8" GWB ON 3 5/8" MTL STUDS @ 24" O.C. (2) LAYERS OF 5/8" GWB ON 7/8" HAT CHANNELS @ 24" O.C., ON 2 1/2" MTL STUDS @ 24" O.C. 1" MIN 1" MIN MIN1/2".COMBO SPRING / NEOPRENE HANGERS - MASON TYPE 30N (1" DEFLECTION) 3" SAFB, TYP. STRUCTURAL BEAM w/ SPRAY APPLIED CEMENTITIOUS FIRE PROOFING (2/HR RATED) STRUCTURAL SLAB & CONC TOPPING SLAB LEVEL 2 16' - 0" (2) LAYERS OF 5/8" GWB ON 7/8" HAT CHANNELS @ 24" O.C., ON 2 1/2" MTL STUDS @ 24" O.C. COMBO SPRING / NEOPRENE HANGERS - MASON TYPE 30N (1" DEFLECTION) 3" SAFB, TYP STRUCTURAL SLAB & CONC TOPPING SLAB RECESSED BOX SAFB CTR LINE DIMENSIONS INDICATED ON INTERIOR ELEVATIONS. WHERE WALL DEVICES OCCUR BACK-TO-BACK, STAGGER BOXES 4" EACH WAY OFF CTR LINE DIMENSION. FIRE RATED GYP. BD. RE: PARTITION TYPES FOR WALL CONSTRUCTION FIRE RATED PUTTY PAD 4" 4" 8" PROVIDE A MIN. OF ONE METAL STUD BTWN BOXES, TYP. ACOUSTICAL SEALANT ALL AROUND DEVICES, TYP. NOTE: RECESSED BOXES SHALL BE STAGGERED ON OPPOSITE SIDE OF WALL. NO BOXES TO BE LOCATED BACK TO BACK, TYP. NOTES: 1. DETAIL SIMILAR AT RATED PARTITIONS WITH SINGLE LAYER OF GYP. BD. ON EACH SIDE. 2. THIS DETAIL TO BE USED FOR RECESSED WALL DEVICE BOX INSTALLATION IN ACOUSTICALLY RATED PARTITIONS THROUGHOUT PROJECT. ACOUSTICAL SEALANT OR PUTTY PADS (NOT FIRE RATED) RECESSED BOXES SAFB HORIZONTAL NON- STRL MTL STUD 3" 3"6"CTR LINE DIMENSIONS INDICATED ON INTERIOR ELEVATIONS. WHERE WALL DEVICES OCCUR BACK-TO-BACK, STAGGER BOXES 3" EACH WAY OFF CTR LINE DIMENSION. 1/2" TYPE 'X' GYP. BD. ON MTL STUD BETWEEN BOXES. GYP. BD. TO BE TIGHT FITTING FOR FULL WIDTH OF STUD CAVITY. SEAL AROUND ANY PENETRATIONS ACOUSTICAL SEALANT OR PUTTY PADS (NOT FIRE RATED) ONE OR TWO LAYERS FIRE RATED GYP. BD. EACH SIDE OF WALL -RE: PARTITION TYPES FOR WALL CONSTRUCTION NOTES: 1. THIS DETAIL TO BE USED FOR RECESSED WALL DEVICE BOX INSTALLATION IN ACOUSTICALLY RATED PARTITIONS THROUGHOUT PROJECT. 3 ADD #5 9" x 12" x 3" BLOCKOUT IN CONC. STRUCTURE VERIFY W/ FINAL TUB AND DRAIN DIMENSIONS U.L. PENETRATION SYSTEM. REFERENCE SPECIFICATIONS FOR GUIDELINES AND ACCEPTABLE SYSTEMS. METAL STUD FRAMING BATHTUB SLEEVE ON C.L. OF TUB CTR. LINE E Q .E Q .9 " V E R IF Y W / M F G .12" VERIFY W/ MFG.3" VERIFY W/ MFG.TUB EDGE DETAIL RE: 8/ A6-20 3 ADD #2 WATERPROOF MEMBRANE ON 1/2" CEMENTITIOUS BACKER BD. WALL TILE SILICONE SEALANT BATH TUB ALUM. SHIMS AS REQ'D FOR LEVELING BATH TUB FLANGE TUB SUPPORT STRINGER THREADED ROD TURNBUCKLE FORGED CLEVIS PIPE CLAMP 3" MIN. CLEARLEVEL 1 0' - 0"5"9"5"CONC. SLAB ON GRADE FLOOR FINISH - REF I.D. 7/8" FURRING CHANNELS @ TOP & BTM 5/8" FRT PLYWD. SHEATHING FLOOR FINISH 1/4" MIN TOPPING SLAB1' - 2"CONC. SLAB ON GRADE ESCUTCHEON PLATES @ EACH POST 4"3"MILLWORK, REF I.D. DOCUMENTS 14 GA BREAK METAL BRACKET @ EACH POST • (4) 2" SELF-TAPPING MASONRY SCREWS @ EACH BRACKET 6"2"DECORATIVE MTL RAIL POST FASTENED TO EACH BRACKET WITH (2) SCREWS 6 6 DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc A6-20 08/27/18 INTERIOR DETAILS 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION 1 1/2" = 1'-0"A6-20 1 ACOUSTIC ISOLATION FURR DOWN @ BALLROOM 1 1/2" = 1'-0"A6-20 2 ACOUSTIC ISOLATION CEILING @ BALLROOM 1 1/2" = 1'-0"A6-20 3 ACOUSTIC ISOLATION FURR DOWN @ FEINSTEIN CLUB 1 1/2" = 1'-0"A6-20 4 ACOUSTIC ISOLATION CEILING @ FEINSTEIN CLUB 3" = 1'-0"A6-20 5 OUTLET BOX DETAIL HORIZONTAL 3" = 1'-0"A6-20 6 OUTLET BOX DETAIL VERTICAL 1 1/2" = 1'-0"A6-20 7 TUB EDGE DETAIL 6" = 1'-0"A6-20 8 TUB EDGE DETAIL 3 ADD #2 1 1/2" = 1'-0"A6-20 9 PIPE GRID HANGER DETAIL 3 ADD #5 3" = 1'-0"A6-20 10 WALL AT SLAB RECESS WITH RAILING 1 1/2" = 1'-0"A6-20 11 ISOMETRIC REVISIONS NO. DATE DESCRIPTION 1 08/27/2018 Issued for construction 3 12/03/2018 General Revisions 6 01/15/2019 General Revisions