A7-03-DOOR-DETAILS-Rev.4
2"10" CAULK (3) LAYERS 5/8" GYP. BD. SCHEDULED DOOR 6" METAL STUDS JAMB ANCHORS PACK FRAME W/INSUL. 1 1/2" RIGID INSULATION WEATHER BARRIER ON (3) LAYERS OF 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION BACKER ROD & SEALANT HOLLOW METAL FRAME 1/2" FIBER CEMENT BOARD SEAL JOINTS FRT WD NAILER 11 1/2"FACE OF STL. STUD 10" 2"8 1/4"CAULK 5/8" GYP. BD. SCHEDULED DOOR 6" METAL STUDS JAMB ANCHORS PACK FRAME W/INSUL. 3" THICK E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION BACKER ROD & SEALANT HOLLOW METAL FRAME BRICK BELOW D SLIDING WOOD/GLASS DOOR PANELS 5/8" GYP. BD. CEILING ON SUSP. MTL. FRAMING (2) LAYERS 5/8" GYP. BD. ON 3 5/8" METAL STUDS - EXTEND TO DECK WOOD TRIM, COUNTERSINK AND & PLUG FASTENERS C 6 X 10.5 WELDED TO VERT. STRUTS 3" FACED S.A.F.B., SECURE TO STUD FRAMING CONTINUOUS TO DECK ABOVE -TYP. EACH SIDE L 4 X 4 X 1/4" STRUTS @ 24" O.C. -FASTEN TO STEEL ANGLE WITH (1) 3/4" BOLT IN 1" LONG SLOTTED HOLE IN EACH STRUT 1 1/2" x 1 1/2" x 20 GA. STEEL ANGLE CONTINUOUS L 5 x 5 x 5/16" WELDED TO BEAM, EACH SIDE (2) LAYERS 5/8" GYPSUM BOARD ON 3 5/8" METAL STUDS @ 16" O.C. - EXTEND TO DECK. ACOUSTIC SEALANT, TYP. FIXED WOOD/GLASS DOOR PANEL WOOD NAILER WOOD TRIM, COUNTERSINK AND & PLUG FASTENERS 9' - 6" A.F.F.1' - 8"SEAL TRACK TO DECK WITH ACOUSTIC SEALANT, TYPICAL NOTE: SEAL AROUND ALL PENETRATIONS IN GYPSUM BOARD BULKHEAD WITH ACOUSTIC SEALANT.1"6" STRUCTURAL STEEL STUD BOX HEADER 10"10" 6 3/8" 1/4" 2 1/4" 1/4" 2 1/4" 1/4" 2 1/4"2"4 1/8" 11' - 2" A.F.F. 5/8" GYP. BD. CEILING ON SUSP. MTL. FRAMING 33 3 CONT. 6" STRUCT. STEEL STUD FASTENED TO STEEL CHANNEL 3 3" SAFB 7 7 D 2 LAYERS 5/8" GYP. BD. ON 3 5/8" METAL STUDS SLIDING WOOD/GLASS DOOR PANELS WOOD JAMB1"1" FIXED WOOD/GLASS DOOR PANEL10"10"4 1/8"2"2 1/4"1/4"2 1/4"1/4"2 1/4"1/4"1/4"6 1/8"1' - 8"2"3 3" FACED S.A.F.B. TYP. EACH SIDE D 2 LAYERS 5/8" GYP. BD. ON 3 5/8" METAL STUDS STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) SLIDING WOOD/GLASS DOOR PANEL WOOD JAMB 10"10"4 1/8"6 3/4"1/4"2 1/4"1/4"1/4"6 1/8"2 LAYERS 5/8" GYP. BD. ON 3 5/8" METAL STUDS 1' - 8"1"1"3" FACED S.A.F.B. TYP. EACH SIDE 2"3 APPLIED STOP ALUMINUM DOOR AND FRAME AS SCHEDULED SHIM AS REQUIRED BACKER ROD & SEALANT METAL HEADER FRAMING R-19 BATT INSULATION 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS RETURN WEATHER BARRIER CORNER TRIM 1" VENEER BRICK SELF ADHERED MEMBRANE FLASHING -WRAP AROUND OPENING BACKER ROD & SEALANT, EACH SIDE 8" STRIP SELF ADHERED MEMBRANE FLASHING -LAP OVER ALUM. FLASHING STL ANGLE LINTEL FLEXIBLE FLASHING w/ WEEPS @ 48" O.C.ALUMINUM DOOR AND FRAME AS SCHEDULED SHIM AS REQUIRED BACKER ROD & SEALANT BACKER ROD & SEALANT BRICK VENEER WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS CORNER TRIM RETURN WEATHER BARRIER 1" PAVERS BELOW 11 APPLIED STOP GLAZING AS SCHED. ALUMINUM DOOR AND FRAME AS SCHEDULED4"APPLIED STOP GLAZING AS SCHED. ALUMINUM DOOR AND FRAME AS SCHEDULED 4" 28 7"10 3/4"1/2"CAULK 5/8" GYP. BD. SCHEDULED DOOR 6" METAL STUDS JAMB ANCHORS PACK FRAME W/INSUL. 3" THICK E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION BACKER ROD & SEALANT HOLLOW METAL FRAME BRICK BELOW 8 1/4"2" 2 LAYERS 1/2" GYP. BD. 1 LAYER 1/2" GYP. BD. HOLLOW METAL FRAME W/ SOUND ATTENUATION IN ACOUSTICALLY RATED WALLS (TYP.) CAULK (EA. SIDE) CORRIDOR 1/2"5 1/8"1/2" 3 5/8" METAL STUD TRACK SCHEDULED DOOR2"6 1/8" NOTE: RE: FLOOR PLANS & PARTITION TYPE LEGEND FOR REQUIRED FIRE RATING & ACOUSTICAL RATING. WHERE SOUND BATTS ARE REQUIRED BY PARTITION TYPE, FRAMES SHALL HAVE BATTS WOOD CASING, WHERE VISIBLE TO PUBLIC VIEW 7 2 LAYERS 1/2" GYP. BD. 1 LAYER 1/2" GYP. BD. HOLLOW METAL FRAME W/ SOUND ATTENUATION IN ACOUSTICALLY RATED WALLS (TYP.) CAULK (EA. SIDE) CORRIDOR 5 1/8"3 5/8" METAL STUDS SCHEDULED DOOR 2"6 1/8"WOODCASING, WHERE VISIBLE TO PUBLIC VIEW 7 3/8" TYP CAULK (EA. SIDE) 3 5/8" METAL STUD TRACK SCHEDULED DOOR 2"1/2" 6 1/8" 1/2" HOLLOW METAL FRAME W/ SOUND ATTENUATION IN ACOUSTICALLY RATED WALLS (TYP.) NOTE: RE: FLOOR PLANS & PARTITION TYPE LEGEND FOR REQUIRED FIRE RATING & ACOUSTICAL RATING. WHERE SOUND BATTS ARE REQUIRED BY PARTITION TYPE, FRAMES SHALL HAVE BATTS 2 LAYERS 5/8" GYP. BD. ON EACH SIDE 7 1/8" WOOD CASING, WHERE VISIBLE TO PUBLIC VIEW. REF. I.D. DOCS FOR ADD'L. INFO. 7 3/8" TYPSCHEDULED DOOR1/2" 6 1/8" 1/2" HOLLOW METAL FRAME W/ SOUND ATTENUATION IN ACOUSTICALLY RATED WALLS (TYP.) NOTE: RE: FLOOR PLANS & PARTITION TYPE LEGEND FOR REQUIRED FIRE RATING & ACOUSTICAL RATING. WHERE SOUND BATTS ARE REQUIRED BY PARTITION TYPE, FRAMES SHALL HAVE BATTS 2 LAYERS 5/8" GYP. BD. ON EACH SIDE CAULK (EA. SIDE) 3 5/8" METAL STUDS JAMB ANCHORS 7 1/8"2" CAULK (EA. SIDE) 3 5/8" METAL STUD TRACK SCHEDULED DOOR 2"4 7/8" 5 7/8" 1/2"1/2" HOLLOW METAL FRAME W/ SOUND ATTENUATION IN ACOUSTICALLY RATED WALLS (TYP.) NOTE: RE: FLOOR PLANS & PARTITION TYPE LEGEND FOR REQUIRED FIRE RATING & ACOUSTICAL RATING. WHERE SOUND BATTS ARE REQUIRED BY PARTITION TYPE, FRAMES SHALL HAVE BATTS 1 LAYER 5/8" GYP. BD. ON EACH SIDE 3/8" TYP1/2" 4 7/8"1/2"5 7/8"1 LAYER 5/8" GYP. BD. ON EACH SIDE CAULK (EA. SIDE) SCHEDULED DOOR 3 5/8" METAL STUDS HOLLOW METAL FRAME W/ SOUND ATTENUATION IN ACOUSTICALLY RATED WALLS (TYP.) NOTE: RE: FLOOR PLANS & PARTITION TYPE LEGEND FOR REQUIRED FIRE RATING & ACOUSTICAL RATING. WHERE SOUND BATTS ARE REQUIRED BY PARTITION TYPE, FRAMES SHALL HAVE BATTS JAMB ANCHORS 2" WOOD CASING, WHERE VISIBLE TO PUBLIC VIEW CAULK (EA. SIDE) 3 5/8" METAL STUD TRACK SCHEDULED DOOR 2"1/2" 6 3/4" 1/2" HOLLOW METAL FRAME W/ SOUND ATTENUATION IN ACOUSTICALLY RATED WALLS (TYP.) NOTE: RE: FLOOR PLANS & PARTITION TYPE LEGEND FOR REQUIRED FIRE RATING & ACOUSTICAL RATING. WHERE SOUND BATTS ARE REQUIRED BY PARTITION TYPE, FRAMES SHALL HAVE BATTS 3 LAYERS 5/8" GYP. BD. 7 3/4" 2 LAYERS 5/8" GYP. BD. WOOD CASING, WHERE VISIBLE TO PUBLIC VIEW. REF I.D. DOCS FOR ADD'L INFO 7 FRIEZE AT CORRIDOR SIDE OF DOORS 101B, 141A, 201C, 211B, 238A, 239A, 240A, 242E, & 243B. -REF I.D. DET 11/PA-DT 5.3 3/8" TYPSCHEDULED DOOR1/2" 6 3/4" 1/2" HOLLOW METAL FRAME W/ SOUND ATTENUATION IN ACOUSTICALLY RATED WALLS (TYP.) 3 LAYERS 5/8" GYP. BD. CAULK (EA. SIDE) 3 5/8" METAL STUDS JAMB ANCHORS7 3/4"2" 3 LAYERS 5/8" GYP. BD. WOOD CASING, WHERE VISIBLE TO PUBLIC VIEW -REF I.D. DOCS FOR ADD'L INFO 7 SCHEDULED DOOR HOLLOW METAL FRAME 2 1/2" METAL STUDS 5/8" GYP. BD. BACKER ROD & SEALANT 6 1/4"4 3/4" BACKER ROD & SEALANT 11 5/8" CMU WALL SCHEDULED DOOR HOLLOW METAL FRAME METAL STUDS 5/8" GYP. BD. BACKER ROD & SEALANT BACKER ROD & SEALANT JAMB ANCHORS CMU WALL REINFORCED CELL EQ.EQ.CAULK (EA. SIDE) 3 5/8" METAL STUD TRACK SCHEDULED DOOR 2"1/2" 5 1/2" 1/2" HOLLOW METAL FRAME W/ SOUND ATTENUATION IN ACOUSTICALLY RATED WALLS (TYP.) NOTE: RE: FLOOR PLANS & PARTITION TYPE LEGEND FOR REQUIRED FIRE RATING & ACOUSTICAL RATING. WHERE SOUND BATTS ARE REQUIRED BY PARTITION TYPE, FRAMES SHALL HAVE BATTS 1 LAYER 5/8" GYP. BD. 6 1/2" 2 LAYERS 5/8" GYP. BD. WOOD CASING, WHERE VISIBLE TO PUBLIC VIEW. REF I.D. DOCS. 7 SCHEDULED DOOR1/2" 5 1/2" 1/2" HOLLOW METAL FRAME W/ SOUND ATTENUATION IN ACOUSTICALLY RATED WALLS (TYP.) NOTE: RE: FLOOR PLANS & PARTITION TYPE LEGEND FOR REQUIRED FIRE RATING & ACOUSTICAL RATING. WHERE SOUND BATTS ARE REQUIRED BY PARTITION TYPE, FRAMES SHALL HAVE BATTS 2 LAYERS 5/8" GYP. BD. CAULK (EA. SIDE) 3 5/8" METAL STUDS JAMB ANCHORS 6 1/2"2"1 LAYER 5/8" GYP. BD. WOOD CASING, WHERE VISIBLE TO PUBLIC VIEW. -REF. I.D. DOCS FOR ADD'L INFO 7 APPLIED STOP ALUMINUM OR GALVANEALED DOORS AND FRAMES AS SCHEDULED 4" 7 APPLIED STOP ALUMINUM OR GALV- ANEALED DOOR AND FRAME AS SCHEDULED BACKER ROD & SEALANT BRICK VENEER WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING SHIM AS REQUIRED 5/8" GYP. BD. ON 6" METAL STUDS R-19 BATT INSULATION CORNER TRIM BACKER ROD & SEALANT RETURN WEATHER BARRIER4" 7 1"RIGID INSUL 11 DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc A7-03 09/12/18 DOOR DETAILS 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION 3" = 1'-0"A7-03 2 DOOR JAMB 3" = 1'-0"A7-03 3 DOOR JAMB 3" = 1'-0"A7-03 8 DOOR HEAD AT SLIDING DOOR PANELS 3" = 1'-0"A7-03 9 DOOR JAMB AT SLIDING PANELS 3" = 1'-0"A7-03 10 DOOR JAMB AT SLIDING PANELS 3" = 1'-0"A7-03 11 DOOR HEAD 3" = 1'-0"A7-03 12 DOOR JAMB 3" = 1'-0"A7-03 13 HEAD @ STOREFRONT 3" = 1'-0"A7-03 14 JAMB @ STOREFRONT 3" = 1'-0"A7-03 1 DOOR JAMB 3" = 1'-0"A7-03 15 DOOR HEAD 3" = 1'-0"A7-03 16 DOOR JAMB 3" = 1'-0"A7-03 4 DOOR HEAD 3" = 1'-0"A7-03 5 DOOR JAMB 3" = 1'-0"A7-03 6 DOOR HEAD 3" = 1'-0"A7-03 7 DOOR JAMB 3" = 1'-0"A7-03 19 DOOR HEAD 3" = 1'-0"A7-03 20 DOOR JAMB 3" = 1'-0"A7-03 17 DOOR HEAD 3" = 1'-0"A7-03 18 DOOR JAMB 3" = 1'-0"A7-03 21 DOOR HEAD 3" = 1'-0"A7-03 22 DOOR JAMB 3" = 1'-0"A7-03 23 JAMB @ STOREFRONT 3" = 1'-0"A7-03 24 DOOR JAMB 3ADD #2 NOTE: INSTALL WD CASING ON HM FRAMES WHERE VISIBLE TO PUBLIC VIEW, TYP. - REF. I.D. DOCS FOR ADD'L. INFO. 7 7 11 REVISIONS NO. DATE DESCRIPTION 3 12/03/2018 General Revisions 7 02/13/2019 General Revisions 11 05/29/2019 General Revisions