HomeMy WebLinkAboutA8-05-COLUMN-DETAILS-Rev.76 Z 1' - 10 5/8"8"1' - 0"1' - 8" 2' - 0" S3A S3A S3A STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 5/8" GYP. BD. ON 6" STRUCT. STL. STUDS BRICK VENEER WATERTABLE, BELOW ALUM. FRAME / GLAZING FACE OF STL. STUDS A7-14 7 SIM./ OPP. 11 8 Z 1' - 10 1/2"8"STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 5/8" GYP. BD. ON 6" STRUCT. STL. STUDS BRICK VENEER WATERTABLE BELOWALUM. FRAME/ GLAZING FACE OF STL. STUDS 8"S3A S3A S2A 2' - 0"10" A7-14 7SIM./ OPP. 11 11 Y S2A S3A1' - 0"1' - 0"1' - 0 1/4"8"6"1' - 0"1' - 0"FACE OF STL. STUD WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING 5/8" GYP. BD. ON 6" STRUCT. STL. STUDS R-19 BATT INSULATION STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) BRICK VENEER FACE OF STL. STUD WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING BRICK VENEER RIGID INSULATION WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 8" FACE OF STL. STUD AIR GAP RIGID INSULATION WATERTABLE, BELOW 11 17 Y 1' - 11 1/4"1' - 8 3/4"11 1/4"6"6"1' - 1 3/8"1' - 6 3/8" STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) BRICK VENEER WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING BRICK VENEER 6" STRUCT. STL. STUDS WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING 6" STRUCT. STL. STUDS 6" STRUCT. STL. STUDS A7-14 5SIM. OPP. ALUM. FRAME/ GLAZING VIF 5 1/4"F.O. STUDF.O. STUDLIMESTONE SURROUND IS CUT AT THIS LOCATION - REF. ELEVATION 3/A3-03 WATERTABLE, BELOW WATERTABLE, BELOW 1' - 9 1/2"2' - 2 1/2"2' - 7 3/8"2' - 4 7/8"4"4" 4"4"4"2 1/2"2 1/2"11 BACKER ROD & SEALANT 1' - 0 3/4"21 Y 1' - 2 7/8"1' - 4 7/8"2' - 0"11"1' - 6 1/2"1' - 1" STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) FACE OF STL. STUD A7-14 5 ALUM. FRAME/ GLAZING LIMESTONE SURROUND IS CUT AT THIS LOCATION - REF. ELEV 3/A3-03 WATERTABLE, BELOW WATERTABLE, BELOW 2 1/2" BACKER ROD & SEALANT BRICK VENEER LIMESTONE SURROUND F.O. STUDF.O. STUDRIGID INSULATION SIM. OPP. 5/8" GYP BD ON 6" STRUCT. STUDS S3A S3A F.O. STUD1' - 1 3/8" 11 16 E 6 3/4"5 3/8"10"11"4"STAIR #1 2ST1 S3BL.4 S3LED.3 1' - 0 1/8"10" STRUCT. STEEL DIAGONAL BRACING STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) STAIR HANDRAIL S1D.2 S3LED.3 1132 R STAIR #2 2ST2 8"1' - 3"2 1/4"FACE OF STL. STUD 5"7"8 1/2" FIBER CEMENT BOARD ON 1 1/2" CONTINUOUS RIGID INSULATION WEATHER BARRIER ON (3) LAYERS F.R. 1/2" GLASS MAT SHEATHING (3) LAYERS F.R. 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS R-19 BATT INSULATION STRUCT. STEEL COLUMN W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 3 LAYERS F.R. 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS S6C 3 ADD #2 3 ADD #43 3 ADD #4 3 ADD #4 S3C CONT. BEAD OF F.R. SEALANT AT JOINT, TYP. 32 K 7"8" STAIR #2 2ST2 10 1/2"9"FACE OF STL. STUD FACE OF STL. STUD S6C 6" STRUCT. STL. STUDS R-19 BATT INSULATION STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) S6C 1/4" FIBER CEMENT BOARD 1 1/2" RIGID INSUL.. WEATHER BARRIER ON 3 LAYERS F.R. 1/2" GLASS MAT SHEATHING 3 LAYERS F.R. 1/2" GYP. BD. R-19 BATT INSULATION 3 LAYERS F.R. 1/2" GYP. BD. NOTE: EAST WALL EXT'R SHEATHING ALTERNATE AT CONTRACTOR'S OPTION: (1) LAYER F.R. 1/2" GLASS MAT SHEATHING ON (2) LAYERS F.R. 1/2" GYP BD. CONTRACTOR CHOICE BASED ON SEQUENCING, CONSTRUCTION TIMING & EXPOSURE OF WALL PANELS TO WEATHER. ADD #2 3 3" THICK E.I.F.S. 3 3 ADD #4 ADD #4 3 ADD #4 3 ADD #4 BACKER ROD & SEALANT PRE-FINISHED 'U'-SHAPED ALUM. FLASHING FRT 2 X 8 NAILER 3 ADD #5 SEALANT BASIC MATERIAL: C CONCRETE M MASONRY (CMU) S STUD BASIC SIZE: 0 7/8" FURRING CHANNEL 1 1 5/8" STUD 2 2 1/2" STUD 3 3 5/8" STUD 4 4" CONCRETE, MASONRY OR STUD 6 6" CONCRETE, MASONRY OR STUD 8 8" CONCRETE, MASONRY OR STUD APPLIED LAYERS: A 1 LAYER 5/8" GYPSUM BOARD B 2 LAYERS 5/8" GYPSUM BOARD C 1 LAYERS 1/2" GYPSUM BOARD D 2 LAYERS 1/2" GYPSUM BOARD E AIR CAVITY F 1 LAYER 5/8" CEMENTITIOUS BACKER BOARD G 1 LAYER 1/2" CEMENTITIOUS BACKER BOARD H 1 LAYER 5/8" MOISTURE RESISTANT GYPSUM BOARD J 1 LAYER 1/2" MOISTURE RESISTANT GYPSUM BOARD K SHAFTWALL CONSTRUCTION L 3 LAYERS 5/8" GYPSUM BOARD MODIFYING CONDITIONS: 1. STC RATED ASSEMBLY. 2. FIRE RATED ASSEMBLY. 3. FIRE RATED ASSEMBLY AND STC RATED ASSEMBLY. 4. SPECIAL FIRE RATED ASSEMBLY AND STC RATED ASSEMBLY. PARTITION TYPE SYMBOL BASIC MATERIAL BASIC SIZE APPLIED LAYERS CODE MODIFYING CONDITIONS CODE M8C.1 PARTITION TYPE LEGEND M8CC.1 1 LETTER = LAYER ON ONE SIDE 2 LETTERS = LAYER ON EACH SIDE 32 Y 1' - 0"1' - 0"4 3/4"9"9" STRUCT. STEEL DIAGONAL BRACING W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) LIMESTONE NICHE R-19 BATT INSULATION 6" STRUCT. STL. STUDS WATERTABLE, BELOW BRICK VENEER 1/4" FIBER CEMENT BD. 1 1/2" RIGID INSULATION WEATHER BARRIER ON 3 LAYERS F.R. 1/2" GLASS MAT SHEATHING NOTE: EAST WALL EXT'R SHEATHING ALTERNATE AT CONTRACTOR'S OPTION: (1) LAYER F.R. 1/2" GLASS MAT SHEATHING ON (2) LAYERS F.R. 1/2" GYP BD. CONTRACTOR CHOICE BASED ON SEQUENCING, CONSTRUCTION TIMING & EXPOSURE OF WALL PANELS TO WEATHER. 3 ADD #2 3 3 ADD #4 ADD #4 3 LAYERS OF F.R. 1/2" GYP BD ON 3 5/8" STUDS 3ADD #4 FRT 2x8 WD NAILER CONT. SEALANT PRE-FINISHED 'L'-SHAPED ALUM. FLASHING -FULL HEIGHT BACKER ROD & SEALANT 3 ADD #5 11 17 U STONE PLINTH BELOW SEALANT & BACKER ROD (EACH SIDE) GFRG 2-PIECE DECORATIVE COLUMN COVER GUARDRAIL 6" STRUCT. STL. STUDS STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 'Z' CLIPS @ 16" O.C. SCREW CLIPS EMBEDDED IN THICKENED GFRC PANEL ENDS 1/4" SHIM STL. ANGLES WELDED TO INSIDE FACE OF FLANGES (VARIES) 2'-1" TO 1'-9 3/4"1' - 7 1/2"EQEQ3 1/4"3 1/4"6"6"2' - 7 1/2" 3/4"3/4" 3/4" 5/8"7/8" 1" EQ EQ 3 ADD #421 U 1'- 1 1/2" (MAX.)1' - 1 1/2" (MAX.)STRONG BACKS @ CORNERS, TYP. GFRC PANELS NESTED 4" STL. STUD BUCK 4" STRUCT. STEEL STUD FRAMING, TYP. SEALANT & BACKER ROD (EACH SIDE) SCREW CLIPS EMBEDDED IN THICKENED GFRC PANEL ENDS SHIM AS REQ'D.EQEQ1' - 7 1/2"6"6"(VARIES) 2'-1" TO 1'-9 3/4" 3 1/4"3 1/4" 3/4" 5/8"7/8" 1" EQ EQ 2' - 7 1/2" 3/4"3/4" GUARDRAIL U 25 1' - 0"1' - 0"1' - 0"1' - 0"STONE PLINTH BELOW BACKER ROD & SEALANT (EACH SIDE) GFRG 2-PIECE DECORATIVE COLUMN COVER STRONG BACKS @ CORNERS, TYP. 6" STRUCT. STEEL STUD FRAMING, TYP SCREW CLIPS EMBEDDED IN THICKENED GFRC PANEL ENDS SHIM, TYP.DOUBLE 6" STUDS @ SCREW CLIPS TYP.1/2"TYP.1"DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc A8-05 08/27/18 COLUMN DETAILS 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION 1 1/2" = 1'-0"A8-05 1 COLUMN 2nd LEVEL 1 1/2" = 1'-0"A8-05 2 COLUMN 2nd LEVEL 1 1/2" = 1'-0"A8-05 3 COLUMN 2nd LEVEL 1 1/2" = 1'-0"A8-05 4 COLUMN 2nd LEVEL 1 1/2" = 1'-0"A8-05 5 COLUMN 2nd LEVEL 1 1/2" = 1'-0"A8-05 9 COLUMN 2nd LEVEL 1 1/2" = 1'-0"A8-05 7 COLUMN 2nd LEVEL 1 1/2" = 1'-0"A8-05 8 COLUMN 2nd LEVEL 1 1/2" = 1'-0"A8-05 6 COLUMN 2nd LEVEL 1 1/2" = 1'-0"A8-05 11 INTERIOR GFRC TRIM AT STEEL COLUMNS 2nd LEVEL 1 1/2" = 1'-0"A8-05 12 INTERIOR ROUND GFRC PANELS - NO STEEL COLUMN 2nd LEVEL 1 1/2" = 1'-0"A8-05 13 COLUMN 2nd LEVEL NOTE: INSTALL INSULATION IN WALLS AS INDICATED IN DETAILS & AS REQUIRED BY PARTITION TYPE DESIGNATION FOR SOUND AND FIRE RATINGS. 3 ADD #2 1 1/2" = 1'-0"A8-05 10 NOT USED 11 REVISIONS NO. DATE DESCRIPTION 1 08/27/2018 Issued for construction 3 12/03/2018 General Revisions 8 03/22/2019 General Revisions 11 05/29/2019 General Revisions