Loading...
HomeMy WebLinkAboutA8-07-COLUMN-DETAILS-Rev.41 G 11 1/2"8" (TO F.O. STUD, TYP.) 3' - 3"2' - 2 1/2"1' - 1 1/4"1' - 1 1/4"11 1/2"2' - 3 1/2"1' - 7 1/2"10"2' - 2 1/2"GRANITE WATERTABLE, BELOW WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 6" STRUCT. STL. STUDS, TYP VENEER BRICK VENEER BRICK 2" TYP 3 5/8" TYP 4" 10 B 11 1/8"7 3/8"9 1/2"1' - 0"10 1/4"9 1/2" S3DD.3 S3D FACE OF STL. STUD FACE OF STL. STUD E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS R-19 BATT INSULATION STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 3 ADD #2 S3C 28 W 1' - 10 3/4"10"2' - 1"6 5/8"10" EQ EQ 10"10"2' - 1"6 5/8" EQ EQ S3DD.3 S3DED.3 S2K.2 S2K.2 S2K.2 S2K.2 S2D.3 S2D.3 STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) FIREPLACE FLUE 32 R 8"1' - 3"FACE OF STL. STUD 4"7"8" 1/4" FIBER CEMENT BD. WEATHER BARRIER ON 3 LAYERS F.R. 1/2" GLASS MAT SHEATHING 3 LAYERS F.R. 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS R-19 BATT INSULATION STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 3 LAYERS F.R. 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS STAIR #2 3ST2 S6C 1 1/2" RIGID INSULATION 3 ADD #2 NOTE: EAST WALL EXT'R SHEATHING ALTERNATE AT CONTRACTOR'S OPTION: (1) LAYER F.R. 1/2" GLASS MAT SHEATHING ON (2) LAYERS F.R. 1/2" M GYP BD. CONTRACTOR CHOICE BASED ON SEQUENCING, CONSTRUCTION TIMING & EXPOSURE OF WALL PANELS TO WEATHER. 3 3 ADD #4 ADD #4 3 ADD #4 3 33 ADD #44 7/8"1' - 1 1/8"S3C S3C S2K.3 11 K 31 1' - 6 1/2"1' - 4"9"1' - 0" STAIR #2 3ST2 FACE OF STL. STUD S3C S6C S3DD.4 10 1/2"S3D 3" THICK E.I.F.S. WEATHER BARRIER ON 3 LAYERS 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 3 LAYERS F.R. 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS 3 ADD #2 S6D.3 1 1/2" THICK E.I.F.S. WEATHER BARRIER ON F.R. 1/2" GLASS MAT SHEATHING EXTEND RATED PARTITION TO BACK SIDE OF EXTERIOR SHEATHING (TYP.) NOTE: EAST WALL EXT'R SHEATHING ALTERNATE AT CONTRACTOR'S OPTION: (1) LAYER F.R. 1/2" GLASS MAT SHEATHING ON (2) LAYERS F.R. 1/2" GYP BD. CONTRACTOR CHOICE BASED ON SEQUENCING, CONSTRUCTION TIMING & EXPOSURE OF WALL PANELS TO WEATHER. 3 ADD #4 3 ADD #4 3 ADD #4 BASIC MATERIAL: C CONCRETE M MASONRY (CMU) S STUD BASIC SIZE: 0 7/8" FURRING CHANNEL 1 1 5/8" STUD 2 2 1/2" STUD 3 3 5/8" STUD 4 4" CONCRETE, MASONRY OR STUD 6 6" CONCRETE, MASONRY OR STUD 8 8" CONCRETE, MASONRY OR STUD APPLIED LAYERS: A 1 LAYER 5/8" GYPSUM BOARD B 2 LAYERS 5/8" GYPSUM BOARD C 1 LAYERS 1/2" GYPSUM BOARD D 2 LAYERS 1/2" GYPSUM BOARD E AIR CAVITY F 1 LAYER 5/8" CEMENTITIOUS BACKER BOARD G 1 LAYER 1/2" CEMENTITIOUS BACKER BOARD H 1 LAYER 5/8" MOISTURE RESISTANT GYPSUM BOARD J 1 LAYER 1/2" MOISTURE RESISTANT GYPSUM BOARD K SHAFTWALL CONSTRUCTION L 3 LAYERS 5/8" GYPSUM BOARD MODIFYING CONDITIONS: 1. STC RATED ASSEMBLY. 2. FIRE RATED ASSEMBLY. 3. FIRE RATED ASSEMBLY AND STC RATED ASSEMBLY. 4. SPECIAL FIRE RATED ASSEMBLY AND STC RATED ASSEMBLY. PARTITION TYPE SYMBOL BASIC MATERIAL BASIC SIZE APPLIED LAYERS CODE MODIFYING CONDITIONS CODE M8C.1 PARTITION TYPE LEGEND M8CC.1 1 LETTER = LAYER ON ONE SIDE 2 LETTERS = LAYER ON EACH SIDE 5 T 9 5/8"8"8"10 1/2" 1' - 1 3/4"1' - 3"9 5/8"1 1/2"S3C S3C S3C S3DD.3 S3C E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) FACE OF STL. STUD FACE OF STL. STUD F 20 6"2 7/8"8"10 1/2"8" S3DED.3 STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS S2A FACE OF STL. STUD FACE OF STL. STUD 21 L 8"1' - 3"11"3"1' - 0 1/2"8"S2K.3 S2K.3 S1DS1C E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS 8 U EQ EQ 3/4"11 5/8"10 3/8"11 5/8" EQ EQ S3DD.3 S3C S3DD.3 S1C S1C S3C S1C S3C STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 8" 13 B EQEQ1' - 10"S2DED.3 S3DD.3 S3DD.3 (2) LAYERS 1/2" GYP. BD. STRONG BACK AT CORNERS, TYP. STRUCT COLUMN W/SPRAY APPLIED FIREPROOFING (2-HR F.R.) S2DED.3 S2DED.3 9 1/2"9 1/2" 30 U 8 1/4"11 5/8"11 3/8"2' - 10 1/2"S3BL.1 S3BB.1 S3B.1 STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) S3B 3 ADD #2 S3A 3 4 B CAST STONE GUARDRAIL 8"1' - 0 1/2"1' - 0 5/8"1' - 0"S3A S3A STRUCT. STEEL BEAM W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) RIGID INSULATION WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 5/8" GYP. BD. ON 6" STRUCT. STL. STUDS BRICK VENEER LIMESTONE SURROUND BRICK VENEER BACKER ROD & SEALANT WHERE GUARDRAIL MEETS BRICK1' - 8 1/8"1 1/2"2 1/2"3 5/8"LINE OF RECESSED NORMAN BRICKS, BELOW 2" AIR GAP F.O. STUDF.O. STUD 11 DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc A8-07 08/27/18 COLUMN DETAILS 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION 1 1/2" = 1'-0"A8-07 11 COLUMN 1st LEVEL EXTERIOR 1 1/2" = 1'-0"A8-07 5 COLUMN 3rd LEVEL 1 1/2" = 1'-0"A8-07 6 COLUMN 3rd LEVEL 1 1/2" = 1'-0"A8-07 7 COLUMN 3rd LEVEL 1 1/2" = 1'-0"A8-07 8 COLUMN 3rd LEVEL 1 1/2" = 1'-0"A8-07 4 COLUMN 3rd LEVEL 1 1/2" = 1'-0"A8-07 1 COLUMN 3rd LEVEL 1 1/2" = 1'-0"A8-07 2 COLUMN 3rd LEVEL 1 1/2" = 1'-0"A8-07 3 COLUMN 3rd LEVEL 1 1/2" = 1'-0"A8-07 9 COLUMN 3rd LEVEL 1 1/2" = 1'-0"A8-07 10 COLUMN 2nd LEVEL NOTE: INSTALL INSULATION IN WALLS AS INDICATED IN DETAILS & AS REQUIRED BY PARTITION TYPE DESIGNATION FOR SOUND AND FIRE RATINGS. 3 ADD #2 1 1/2" = 1'-0"A8-07 12 COLUMN 2nd LEVEL 11 REVISIONS NO. DATE DESCRIPTION 1 08/27/2018 Issued for construction 3 12/03/2018 General Revisions 11 05/29/2019 General Revisions