Loading...
HomeMy WebLinkAboutA8-08-COLUMN-DETAILS-Rev.5R 15 1' - 2 1/2"1' - 6"11" 1' - 6"11" FACE OF STL. STUD STRUCT. STEEL COLUMN W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED)S3C S3C E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 5/8" GYP. BD. ON 6" STRUCT. STL. STUDS PARAPET WALL BELOW LINE OF SHAFT WALL AROUND ELEVATOR BELOW8" 15 M 1' - 0"1' - 6"11" 8"9 1/4"9"STRUCT. STEEL COLUMN W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) S3C S3A FACE OF STL. STUD E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHINGR-19 BATT INSULATION 5/8" GYP. BD. ON 6" STRUCT. STL. STUDS PARAPET WALL BELOW LINE OF SHAFT WALL AROUND ELEVATOR BELOW FACE OF STL. STUD 5/8" GYP. BD. ON 6" STRUCT. STL. STUDS 18 N SERVICE ELEV. 7 1/4"7 1/4" 1' - 3 3/4" S3D S2K.3 S4K.3 STRUCT. STEEL COLUMN W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) STRUCT. STEEL FRAMING/BRACING W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 21 N SERVICE ELEV. 1' - 1" 11"7 1/4" 1' - 3 3/4" S2K.3 S4K.3 S3D STRUCT. STEEL COLUMN W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) FACE OF STL. STUD E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 5/8" GYP. BD. ON 6" STRUCT. STL. STUDS STRUCT. STEEL FRAMING/BRACING W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 11" 32 R PARAPET WALL S3C STRUCT. STEEL COLUMN W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) STAIR #2 7ST21' - 3" 1' - 3" 4" 7" 8" FACE OF STL. STUD WEATHER BARRIER ON 3 LAYERS F.R. 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 3 LAYERS F.R. 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS (2) LAYERS OF 1/2" GLASS MAT SHEATHING 8" S6C FACE OF STL. STUD (2) LAYERS 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS NOTE: EAST WALL EXT'R SHEATHING ALTERNATE AT CONTRACTOR'S OPTION: (1) LAYER 1/2" GLASS MAT SHEATHING ON (2) LAYERS 1/2" MR GTP BD. CONTRACTOR CHOICE BASED ON SEQUENCING, CONSTRUCTION TIMING & EXPOSURE OF WALL PANELS TO WEATHER. 3 ADD #2 1 1/2" RIGID INSUL. 1/4" FIBER CEMENT BD. 3 3 ADD #4 ADD #4 11 11 BASIC MATERIAL: C CONCRETE M MASONRY (CMU) S STUD BASIC SIZE: 0 7/8" FURRING CHANNEL 1 1 5/8" STUD 2 2 1/2" STUD 3 3 5/8" STUD 4 4" CONCRETE, MASONRY OR STUD 6 6" CONCRETE, MASONRY OR STUD 8 8" CONCRETE, MASONRY OR STUD APPLIED LAYERS: A 1 LAYER 5/8" GYPSUM BOARD B 2 LAYERS 5/8" GYPSUM BOARD C 1 LAYERS 1/2" GYPSUM BOARD D 2 LAYERS 1/2" GYPSUM BOARD E AIR CAVITY F 1 LAYER 5/8" CEMENTITIOUS BACKER BOARD G 1 LAYER 1/2" CEMENTITIOUS BACKER BOARD H 1 LAYER 5/8" MOISTURE RESISTANT GYPSUM BOARD J 1 LAYER 1/2" MOISTURE RESISTANT GYPSUM BOARD K SHAFTWALL CONSTRUCTION L 3 LAYERS 5/8" GYPSUM BOARD MODIFYING CONDITIONS: 1. STC RATED ASSEMBLY. 2. FIRE RATED ASSEMBLY. 3. FIRE RATED ASSEMBLY AND STC RATED ASSEMBLY. 4. SPECIAL FIRE RATED ASSEMBLY AND STC RATED ASSEMBLY. PARTITION TYPE SYMBOL BASIC MATERIAL BASIC SIZE APPLIED LAYERS CODE MODIFYING CONDITIONS CODE M8C.1 PARTITION TYPE LEGEND M8CC.1 1 LETTER = LAYER ON ONE SIDE 2 LETTERS = LAYER ON EACH SIDE U 14 10"8" FACE OF STL. STUD STRUCT. STEEL COL W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 5/8" GYP. BD. ON 6" STRUCT. STL. STUDS 18 M 9"1' - 2 1/2"1' - 0"1' - 11 1/2"7 1/4" FACE OF STL. STUD S4K.3 S2K.3 STRUCT. STEEL COLUMN W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) E.I.F.S. WEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS STRUCT. STEEL DIAGONAL BRACING W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) STRUCT. STEEL FRAMING / BRACING w/ SPRAY APPLIED FIREPROOFING (2 HR. RATED) 3" SERVICE ELEV. SHAFT 5/8" GYP. BD. ON 6" STRUCT. STL. STUDS K 31 STAIR #2 7ST2 1' - 0"1' - 0"9"9"10 1/2"FACE OF STL. STUD STRUCT. STEEL COL W/ SPRAY APPLIED FIRE- PROOFING (2 HR. RATED) 3" THICK E.I.F.S. WEATHER BARRIER ON 3 LAYERS 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS FACE OF STL. STUD S3D S6C FACE OF STL. STUD 3 LAYERS 1/2" GYP. BD. ON 6" STRUCT. STL. STUDS 13 G 11"11"11"10" S3A S2A S3A S2A STRUCT STEEL COLUMN W/ SPRAY APPLIED FIREPROOFING (2 HR RATED) S3AA 3 3 3 7 G S2A S3A S2A S3A11"11"11"11" STRUCT STEEL COLUMN w/ SPRAY APPLIED FIREPROOFING (2 HR RATED) 3 3 TRIM, WHERE OCCURS. -REF I.D. DRAWINGS J 19 1' - 0"1' - 0" STRUCT STEEL COLUMN W/ SPRAY APPLIED FIREPROOFING (2 HR RATED)8"8"FRP CORNER GUARDS, TYP. ALL CORNERS S3A S3A S3A S3A 3 A 16 1' - 2 1/2" 1 1/2" 1 1/2" WALK-IN FREEZER PANELS S3BED.3 1' - 1"1 1/2"1 1/2"1' - 7 5/8"F.O. CMU F.O. CMU1' - 9 1/8"F.O. BRICKF.O. BRICK 6" CMU 8" CMU 8" CMU WATERTABLE, BELOW AIR GAP RIGID INSULATION BRICK VENEER WEATHER BARRIER 11 1/2"7 3/8"A 13SLAB EDGE1' - 0"1' - 1"6 5/8"11 1/2"1/2"1 1/2"2' - 9" (6" STUD WALL)CMU WALL 2 1/2"2 5/8"1 1/2"1 1/2"LIMESTONE NICHE WATERTABLE, BELOW VENEER BRICK 1 1/2"5 3/8"7 5/8"F.O. BRICK2 1/2"WALK-IN FREEZER PANELS BACKER ROD & SEALANT RIGID INSUL. RIGID INSULATIONWEATHER BARRIER ON 1/2" GLASS MAT SHEATHING R-19 BATT INSULATION Z 1 1/2"1' - 10"8"1 1/2" THK EIFS (3) LAYERS OF 1/2" GLASS MAT SHEATHING WEATHER BARRIER (1) LAYER OF 1/2" GLASS MAT SHEATHING ON NORTH SIDE (1) LAYER OF 1/2" GLASS MAT SHEATHING (3) LAYERS OF 1/2" GYP BD(1) LAYER OF 1/2" GYP BD (3) LAYERS OF 1/2" GYP BD (3) LAYERS OF 1/2" GYP BD (1) LAYER OF 1/2" GYP BD LOAD BEARING STRUCTURAL STUD WALL -2-HR FIRE RATED EXTEND GYP BD TO INSIDE FACE OF SHEATHING, TYP 7/8" FURRING CHANNELS @ 16" O.C. VERT DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc A8-08 08/27/18 COLUMN DETAILS 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION 1 1/2" = 1'-0"A8-08 1 COLUMN 7th LEVEL 1 1/2" = 1'-0"A8-08 2 COLUMN 7th LEVEL 1 1/2" = 1'-0"A8-08 3 COLUMN 7th LEVEL 1 1/2" = 1'-0"A8-08 4 COLUMN 7th LEVEL 1 1/2" = 1'-0"A8-08 5 COLUMN 7th LEVEL 1 1/2" = 1'-0"A8-08 8 COLUMN 7th LEVEL 1 1/2" = 1'-0"A8-08 6 COLUMN 7th LEVEL 1 1/2" = 1'-0"A8-08 7 COLUMN 7th LEVEL NOTE: INSTALL INSULATION IN WALLS AS INDICATED IN DETAILS & AS REQUIRED BY PARTITION TYPE DESIGNATION FOR SOUND AND FIRE RATINGS. 1 1/2" = 1'-0"A8-08 9 KITCHEN COLUMN FURR OUT 1 1/2" = 1'-0"A8-08 10 TYP COLUMN FURR OUT @ RESTAURANT 3 ADD #2 3 1 1/2" = 1'-0"A8-08 11 COLUMN DETAIL - KITCHEN 1 1/2" = 1'-0"A8-08 13 COLUMN 1st LEVEL 1 1/2" = 1'-0"A8-08 12 COLUMN 1st LEVEL 11 1 1/2" = 1'-0"A8-08 14 LOAD BEARING WALL 17 RFI #107 REVISIONS NO. DATE DESCRIPTION 1 08/27/2018 Issued for construction 3 12/03/2018 General Revisions 11 05/29/2019 General Revisions 17 08/28/2019 General Revisions