HomeMy WebLinkAboutA9-06-ELEVATOR-SECTIONS-Rev.3LEVEL 2 16' - 0" LEVEL 1 0' - 0" NR M1 A9-07 16' - 0"5' - 0"EXISTING GARAGE LEVEL -3' - 7 3/4" ELEVATOR PIT ELEVATOR CAB STRUCTURAL DIVIDER FRAMING, TYP. ELEVATOR DOOR, TYP. RE:JAMB DETAIL . ELEVATOR PIT LADDER S4K.3 S2K.2/19 A7-05 AT LOCATIONS WHERE T.S. GUIDE COLUMN IS INSTALLED PER THE ECCENTRIC DETAIL SHOWN ON SHEET S501, THEN COVER THE GAP w/ 22ga GALV. SHEET METAL, CONTINUOUS 11 RFI #073 LEVEL 6 62' - 0" NR M 3 A9-07 LEVEL 7 (ROOF) 73' - 6" ELEVATOR CAB ELEC 606 ELEVATOR VENTS ROOF FRAMING DIVIDER BEAM, TYP. ELEVATOR DOOR, TYP. RE: JAMB DETAIL . S4K.3 S4K.3 /19 A7-05 S4K.3 S4K.3 A9-08 4 SIM. OPP.11 11 RFI #073 RFI #073 LEVEL 2 16' - 0" LEVEL 1 0' - 0" LEVEL 3 32' - 0" LEVEL 4 42' - 0" LEVEL 5 52' - 0" LEVEL 6 62' - 0" NR M A9-06 5 A9-06 6 LEVEL 7 (ROOF) 73' - 6" EXISTING GARAGE LEVEL -3' - 7 3/4"1' - 0 1/4"13' - 7 3/4"TOTAL TRAVEL DISTANCE = 62' - 0"5' - 0"PASSENGER ELEVATOR HOISTWAY PASSENGER ELEVATOR HOISTWAY A9-08 4 8 1/8" AT LOCATIONS WHERE T.S. GUIDE COLUMN IS INSTALLED PER THE ECCENTRIC DETAIL SHOWN ON SHEET S501, THEN COVER THE GAP w/ 22ga GALV. SHEET METAL, CONTINUOUS 11 TYP. 11 RFI #073 LEVEL 2 16' - 0" LEVEL 1 0' - 0" LEVEL 3 32' - 0" LEVEL 4 42' - 0" LEVEL 5 52' - 0" LEVEL 6 62' - 0" LNM A9-06 2 A9-06 3 LEVEL 7 (ROOF) 73' - 6" EXISTING GARAGE LEVEL -3' - 7 3/4"1' - 0 1/4"16' - 5 3/4"TOTAL TRAVEL DISTANCE = 62' - 0"5' - 0"SERVICE ELEVATOR HOISTWAY LEVEL 2 16' - 0" LEVEL 1 0' - 0" LNM1 A9-07 16' - 0"5' - 0"EXISTING GARAGE LEVEL -3' - 7 3/4" A9-08 1 ELEVATOR PIT ELEVATOR CAB (LOWEST POSITION) ELEVATOR PIT LADDER S4K.3S2K.2 LEVEL 6 62' - 0" LNM 1 A9-07 LEVEL 7 (ROOF) 73' - 6" S4K.3 S2K.3 DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc A9-06 09/12/18 ELEVATOR SECTIONS 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION 3/8" = 1'-0"A9-06 5 PASSENGER ELEVATORS #1 & #2 PARTIAL SECTION 3/8" = 1'-0"A9-06 6 PASSENGER ELEVATORS #1 & #2 PARTIAL SECTION 1/4" = 1'-0"A9-06 4 PASSENGER ELEVATORS #1 & #2 OVERALL SECTION 1/4" = 1'-0"A9-06 1 SERVICE ELEVATOR OVERALL SECTION 3/8" = 1'-0"A9-06 2 SERVICE ELEVATOR PARTIAL SECTION 3/8" = 1'-0"A9-06 3 SERVICE ELEVATOR PARTIAL SECTION 3 ADD #2 REVISIONS NO. DATE DESCRIPTION 3 12/03/2018 General Revisions 11 05/29/2019 General Revisions