Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A10-08-ENLARGED-REFLECTED-CEILING-PLANS-Rev.4
RCP LEGEND sCEILING MOUNTED SPEAKER CEILING MOUNTED SPRINKLER HEAD CEILING ACCESS PANEL WALL SCONCE SIDEWALL DIFFUSER RECESSED CAN LIGHT PENDANT FIXTURE EXHAUST GRILL STRIP FIXTURE WALL WASHER RESTROOM WALL SCONCE LINEAR DIFFUSER LSPLOUDSPEAKER PENDANT CHANDELIER PIN LIGHT GYPSUM BOARD CEILING *CEILING NOTES: 1. ALL CEILING HEIGHTS TAKEN FROM FINISH FLOOR LEVEL. 2. REFER TO INTERIOR DESIGN DRAWINGS FOR ADDITIONAL INFORMATION @ PUBLIC FRONT OF HOUSE SPACES AND GUEST UNIT CEILING RCPs. EXIT LIGHT 2X LAY-IN CEILING FIXTURE SUPPLY DIFFUSER 2X ACOUSTICAL CEILING TILE 11 11 D D F F 9 9 4 4 7 7 16 16 15 15 13 13 E G G B B 1 A5-06 3 A5-06 A.F.F.12' - 4" A.F.F.11' - 4" A.F.F.12' - 4" A.F.F.11' - 4" A.F.F.12' - 6" A.F.F.11' - 4" A.F.F.11' - 4" A.F.F.12' - 6" A.F.F.12' - 6" BALLROOM 2461' - 0"ACOUSTIC ISOLATION SOFFIT ACOUSTIC ISOLATION SOFFIT 5 A4-05 A.F.F.12' - 6" A.F.F.11' - 4" DRAPERY POCKET, TYP. GYPSUM BOARD ON MTL FRAMING SYSTEM SECURED TO ACOUSTIC ISOLATION FRAMING ABOVE, TYP. REF I.D. DRAWINGS FOR ADDITIONAL INFORMATION. A.F.F.12' - 6" A.F.F.11' - 4" 1 A4-05 3 DRAPERY POCKET DRAPERY POCKET DRAPERY POCKET DRAPERY POCKET DRAPERY POCKET 1' - 2"12' - 1 1/2"2' - 4"11' - 2"5' - 6"11' - 3 1/2"2' - 4"11' - 9 7/8" EQ EQ EQ EQ EQ EQ EQ EQ GFRG PILASTER 2' - 8 1/4"12' - 3 3/4"12' - 3 3/4"12' - 3 3/4"2' - 2"S S S S S S S S S S S S 1' - 6"3' - 0 1/2"4' - 3 1/2"4' - 3 1/2"3' - 8 1/2"4' - 3 1/2"4' - 3 1/2"3' - 8 1/2"4' - 3 1/2"4' - 3 1/2"3' - 0 1/2"1' - 0"10' - 7"12' - 3"12' - 4"4' - 1"TYP. 1' - 10" TYP. 1' - 10" TYP. 1' - 10" TYP. 1' - 10" A.F.F.12' - 4" CEILING CEILING CEILING A.F.F.12' - 4" A.F.F.11' - 4" ACOUSTIC ISOLATION SOFFIT CEILING CHANDELIER FIXTURE, TYP. RECESSED LIGHT FIXTURE, TYP. SPEAKER, TYP.LINEAR DIFFUSER, TYP. SOFFIT SOFFIT SOFFIT SOFFIT A.F.F.12' - 6" DRAPERY POCKET A.F.F.12' - 4" DRAPERY POCKET OCC SENSOR -ALIGN w/ FIXTURES ALIGN LINEAR DIFFUSERS AT WEST WALL w/ CHANDELIERS, TYP. 22 22 RFI #201 NOTE: ALIGN SPRINKLER HEADS w/ CEILING FIXTURES. CENTER BETWEEN FIXTURES. NOTE: VERIFY ALL HVAC DIFFUSER LOCATIONS w/ I.D. REFLECTED CEILING PLANS TO VERIFY COORDINATE w/ CEILING TRIM NOTE: REFER TO I.D. REFLECTED CEILING PLANS FOR ADDITIONAL CEILING HEIGHTS NOT NOTED IN THIS PLAN EX31 EX31 1' - 2" 11 11 D D F F 9 9 4 4 7 7 16 16 15 15 13 13 E G G B B 2 A9-03 1 A5-12 ACOUSTICAL ISOLATION CEILING SUSPENDED FROM STRUCTURE ABOVE ACOUSTICAL ISOLATION CEILING SUSPENDED FROM STRUCTURE ABOVE A.F.F.14' - 5" A.F.F.14' - 5" A.F.F.14' - 5" A.F.F.14' - 5" A.F.F.14' - 5" A.F.F.14' - 5" DUCTWORK FURRDOWN WALLS FURRDOWN WALLS DUCTWORK A.F.F.13' - 8" A.F.F.13' - 8"A.F.F.13' - 8" A.F.F.13' - 8" A.F.F.13' - 8" 1 A4-05 21 21 RFI # 189 RFI # 189 EX31 EX31 ACOUSTIC ISOLATION CEILING NOTES 1. LIMIT PENETRATIONS THRU CEILING. 2. ALL J-BOXES & OTHER DEVICES TO BE SURFACE MOUNTED. 3. RIGGING SHALL BE SURFACE MOUNTED USING ISOLATION BOLTS W/ NEOPRENE BUSHINGS/WASHERS. 4. FOR SYSTEMS THAT MUST BE SUPPORTED BY THE SLAB ABOVE, SUSPENSION SHALL BE PROVIDED VIA DROP RODS SUPPORTED FROM SOUND BARRIER CEILING ISOLATORS. DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc A10-08 09/12/18 ENLARGED REFLECTED CEILING PLANS 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"A10-08 1 ENLARGED BALLROOM RCP 1/4" = 1'-0"A10-08 2 ENL.BALLROOM RCP (ACOUSTIC ISOLATION CEILING) ADD #2 3 21 RFI #189 21RFI #189 NO. DATE DESCRIPTION 3 12/03/2018 General Revisions 21 12/04/2019 General Revisions 22 12/23/2019 General Revisions