Loading...
HomeMy WebLinkAboutA10-09-ENLARGED-REFLECTED-CEILING-PLANS-Rev.5H AP AP CAM CAMCAM ONTONTONTONTS S S S 26 282725 S Q WOMEN'S LOCKER 135 MEN'S LOCKER 134 CORRIDOR 120 A.F.F.8' - 0" A.F.F.9' - 0"A.F.F.9' - 0" A.F.F.8' - 0" 4 A4-05 RCP LEGEND sCEILING MOUNTED SPEAKER CEILING MOUNTED SPRINKLER HEAD CEILING ACCESS PANEL WALL SCONCE SIDEWALL DIFFUSER RECESSED CAN LIGHT PENDANT FIXTURE EXHAUST GRILL STRIP FIXTURE WALL WASHER RESTROOM WALL SCONCE LINEAR DIFFUSER LSPLOUDSPEAKER PENDANT CHANDELIER PIN LIGHT GYPSUM BOARD CEILING *CEILING NOTES: 1. ALL CEILING HEIGHTS TAKEN FROM FINISH FLOOR LEVEL. 2. REFER TO INTERIOR DESIGN DRAWINGS FOR ADDITIONAL INFORMATION @ PUBLIC FRONT OF HOUSE SPACES AND GUEST UNIT CEILING RCPs. EXIT LIGHT 2X LAY-IN CEILING FIXTURE SUPPLY DIFFUSER 2X ACOUSTICAL CEILING TILE J L 181513 G M 2 A4-02 19 3 A4-041' - 8 1/2"1' - 8 1/2"ALIGN SOFFIT WITH COLUMN FURROUT 20 RFI #158 A.F.F.7' - 10" A.F.F.7' - 10" A.F.F.7' - 10" A.F.F.8' - 10" A.F.F.7' - 10" J FITNESS 310 3' - 0"2' - 0"10"1' - 9"5' - 6"7' - 3"7' - 3"1' - 0"6' - 6"6' - 6"2' - 8 7/8" 2' - 0"2' - 11"4' - 6" 2' - 10" 11 17 21 U W 14 X 12' - 10"4' - 1"8' - 1 1/2"3' - 10 1/2"13' - 1"6' - 11"3' - 7"7' - 0"3' - 5"5' - 4 1/2"12' - 1 1/2"12' - 1 1/2"5' - 4 1/2"3' - 7" 5' - 11"15' - 0"15' - 0"6' - 1"4' - 6 3/8"4' - 2"4' - 2"4' - 7 5/8"10" 1' - 1 5/8" 1' - 5 3/8"17' - 6"17' - 6"1' - 5 3/8" 11 5/8" 1' - 2"10 5/8"1' - 1 5/8"6' - 8 1/8"6' - 8 1/8"11 1/2"1' - 2"S S S 6' - 3"RECESSED CAN FIXTURE, TYP. SPEAKER, TYP. CHANDELIERS, TYP. LINEAR HVAC GRILL, CENTER IN FURR-DOWN, TYP. EQ.EQ. LINEAR HVAC GRILL, CENTER IN FURR- DOWN, TYP. 21 23 26 28 30 32 Y Y U U 2925 1 A4-02 1 A4-03 ZZ 1 A5-04 1 A5-02 1 A5-03 2 A5-03 1 A5-01 3 A5-12 2 A5-16 4 A5-12 S 2' - 6"11' - 5 3/4"2' - 6" 1' - 1"4' - 8"4' - 8"1' - 1" OCC SENSOREQ EQ2' - 6"2' - 6"1' - 2" 1' - 2"11' - 8"1' - 2"1' - 2"24' - 2 3/4" 2' - 11 1/2" 8"12' - 1 3/4"10"5 3/4" 3' - 5"2' - 5"2' - 5"3' - 5"3' - 8 1/4"4' - 9 1/8"3' - 8 1/4" EQ EQ 4" EQ EQ EQ EQ S S S S SSS 3' - 10"2' - 0"2' - 0"3' - 10"1' - 2"1' - 2"23' - 11 3/8"1' - 0"1' - 0"4' - 3 1/2"4' - 8"4' - 8"6' - 0 1/4"4' - 3 1/2"1' - 3"1' - 3"1' - 3"1' - 3"1' - 3"1' - 3"4' - 8"2' - 0" 2' - 0" 6' - 10 1/4" 2' - 0" 2' - 0"4' - 8" 4' - 3"4' - 11 5/8"5' - 9"4' - 11 5/8"4' - 3" EQ EQ 2' - 5 3/4"2' - 5 3/4" 6' - 8" (VIF)6' - 5 3/8"4' - 8"4' - 8"10' - 5"1' - 11"EQ EQ1' - 0"1' - 0"2' - 10"18' - 5 1/8"5' - 2"1' - 0"1' - 0"2' - 10"6' - 4"4' - 2"2' - 7"2' - 7"4' - 3"5' - 0"4' - 11 1/8"4' - 3"1' - 5"1' - 5"SS 1' - 9"1' - 3"4' - 8"8' - 6"8' - 7"4' - 8"2' - 8"20' - 4"2' - 8"EQEQ1' - 2"1' - 2"EQ EQ EQ EQ 11"EQ EQ 11"1' - 9"11"SPEAKERS, TYP. LINEAR SUPPLY DIFFUSERS, TYP. SOFFITS S EQEQLINEAR SLOT DIFFUSER EQ EQ 2' - 3"5' - 6 3/4"3' - 1"CENTER DIFFUSERS IN OPENINGS 1' - 2" 1' - 2" 5' - 9 1/2"14' - 1"5' - 9 1/2" CEILING 10'-8" CEILING 11'-0" CEILING 11'-10" CEILING 11'-10" CEILING 11'-10" SOFFIT 10'-6" CEILING 10'-6" SOFFIT 10'-6" SOFFIT 12'-8" SOFFIT 12'-2" SOFFIT 12'-2" CEILING 13'-2" SOFFIT 11'-10" CORNICE TRIM SHOWN DASHED, TYP. -REF I.D. SHEETS FOR ADD'L INFO CEILING 13'-2" SOFFIT 11'-10" SOFFIT 12'-2" 11"CEILING 12'-4" CEILING 12'-8" SOFFIT 11'-2" SOFFIT 10'-10" SOFFIT 12'-8" SOFFIT 12'-2"7' - 6"11' - 0 1/4"7' - 11"SOFFIT 10'-6"EQEQLINEAR SUPPLY DIFFUSER, TYP. NOTE: VERIFY ALL HVAC DIFFUSER LOCATIONS w/ I.D. REFLECTED CEILING PLANS TO VERIFY COORDINATE w/ CEILING TRIM NOTE: REFER TO I.D. REFLECTED CEILING PLANS FOR ADDITIONAL CEILING HEIGHTS NOT NOTED IN THIS PLAN 1' - 2"1' - 2"SOFFIT 10'-6" SOFFITS 10'-6" CEILING 10'-6" OCC SENSOR 3' - 2"6' - 6 1/2"3' - 2"EQ EQ CEILING 12'-4" CEILING 9'-0" SOFFIT 10'-0"SOFFIT 10'-6"SOFFIT 10'-0" 1' - 2"1' - 2" 2' - 4"1' - 8"1' - 8"SOFFIT 10'-0" 1' - 2"1' - 2" SOFFIT 12'-2" SOFFIT 12'-8" LIGHT COVE, TYP. VESTIBULE 204 CART STOR. 216 CART STOR 209 LOBBY 202 LOBBY BAR 207 LIBRARY 210 BOARDROOM 211 GM 212 REVENUE 214 VEST 213 CORRIDOR 203CEILING 11'-10" NOTE: ALIGN SPRINKLER HEADS w/ CEILING FIXTURES. CENTER BETWEEN FIXTURES.DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc A10-09 09/12/18 ENLARGED REFLECTED CEILING PLANS 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION 1/4" = 1'-0"A10-09 1 ENL. RCP @ LOCKER ROOMS 3 ADD #2 1/4" = 1'-0"A10-09 2 ENLARGED RCP @ FITNESS 1/4" = 1'-0"A10-09 3 CEILING OVER GRAND STAIR 21 RFI #192 1/4" = 1'-0"A10-09 4 ENLARGED RCP - VESTIBULE, LOBBY, LOBBY BAR, & BOARDROOM 22 RFI #201 NO. DATE DESCRIPTION 3 12/03/2018 General Revisions 20 11/06/2019 General Revisions 21 12/04/2019 General Revisions 22 12/23/2019 General Revisions