Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E-000-Electrical-Symbols,-Schedules-and-Abbreviations-Rev.3
T T CT G M M TS M FT DK K FAA FACP EVAC FATC BATT ASFP TPR IAM ZAM CR DH H F S S D RTS S A S E S SC S V B R B S C F H H F H2 D FS FS PS TS PIV EOL W TV TV M M M S S S P P IC MI VC TCC C CCTV MTV B B B DR ES IC MI MD ML CR SCP DC K ? ? ? ? DT G H K KP LV LM MC P T WP D M CM D WM C J # M D S SP F CB C AUTO/MANUALNLETRANSFER SWITCH xxA-xP XX' xxxV WIRE WAY XX' xxxV BUS DUCT xxx KVA xxxV x∅xW PRI Tx xxxY/xxxV x∅xW SEC xxx KW xxxV x∅ GENERATOR G DRAWING BLOCK TITLE SCALE:1/8" = 1'-0"0 16'8'4' N xxAF yyAT xxAF yyAT xxAF yyAT xxAF yyAT xxAF yyAT zzA CT zzA zzA zzA K2 XX-XX-X-X 3 MO PANEL ST 1 GFCI (3) (3) 400-5A AFD 3 xx-x-x A1 E-401 A1 E-501 A1 E-301 GENERAL ELECTRICAL NOTES GENERAL NOTES:NOTES THAT APPLY EQUALLY TO ALL DISCIPLINES WITHIN THE DRAWING SET. GENERAL ELECTRICAL NOTES: NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN THE DISCIPLINE. GENERAL SHEET NOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR. SHEET KEYNOTES:NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR AND USE A KEYNOTE INDICATOR TO IDENTIFY ITEMS. SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA FOR ADDITIONAL INFORMATION. KEYNOTE INDICATOR: REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL INFORMATION. DETAIL INDICATOR:REFERENCE DETAIL LOCATION FOR ADDITIONAL INFORMATION. DRAWING BLOCK TITLE INDICATOR: REFERENCE DRAWING MODULE LOCATION FOR ADDITIONAL INFORMATION. MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL INFORMATION. REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. LIGHTING INDICATOR:REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. "A" = FIXTURE TYPE, REFER TO FIXTURE SCHEDULE, "2" = CIRCUIT NUMBER, "a" = SWITCH IDENTIFICATION SURFACE MOUNTED 2'x4' FIXTURE SURFACE MOUNTED 2'x4' EMERGENCY FIXTURE RECESSED MOUNTED 2'x4' FIXTURE RECESSED MOUNTED 2'x4' EMERGENCY FIXTURE SURFACE MOUNTED 1'x4' FIXTURE SURFACE MOUNTED 1'x4' EMERGENCY FIXTURE RECESSED MOUNTED 1'x4' FIXTURE RECESSED MOUNTED 1'x4' EMERGENCY FIXTURE SURFACE MOUNTED FIXTURE SURFACE MOUNTED EMERGENCY FIXTURE RECESSED MOUNTED FIXTURE RECESSED MOUNTED EMERGENCY FIXTURE POLE MOUNTED FIXTURE POLE MOUNTED EMERGENCY FIXTURE SUSPENDED FIXTURE SUSPENDED EMERGENCY FIXTURE WALL MOUNTED FIXTURE WALL MOUNTED EMERGENCY FIXTURE WALL MOUNTED FIXTURE WALL MOUNTED EMERGENCY FIXTURE LUMINAIRE STRIP TYPE FIXTURE (2 FOOT) LUMINAIRE STRIP TYPE FIXTURE (3 FOOT) LUMINAIRE STRIP TYPE FIXTURE (4 FOOT) EXIT LIGHTING FIXTURE, ARROWS AND EXIT FACE AS INDICATED ON DWGS (MOUNTING HEIGHTS TO BE DETERMINED BY JOB SPECIFICATION FIXTURE-DOUBLE OR SINGLE HEAD SPOT LIGHT EMERGENCY BATTERY UNIT WITH LIGHTING HEADS EMERGENCY BATTERY REMOTE LIGHTING HEADS LIGHT TRACK, LENGTH AS INDICATED ON DWGS WITH NUMBER OF LIGHTS INDICATED ON DWGS AND SCHEDULE IN-GROUND OR FLOOR MOUNTED FIXTURE SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE TWIN LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE ROADWAY LUMINAIRE-COBRA HEAD BOLLARD TYPE SITE LIGHTING FIXTURE LIGHTING OR POWER PANEL, RECESSED LIGHTING OR POWER PANEL, SURFACE DISTRIBUTION PANEL LIGHTING OR POWER PANEL ON NORMAL/GENERATOR FEEDER DISTRIBUTION PANEL ON NORMAL/GENERATOR FEEDER MOTOR CONTROL CENTER (MCC) DRY TYPE TRANSFORMER TRANSFORMER-PAD MOUNT CURRENT TRANSFORMER CABINET GENERATOR METER METER AND SOCKET TRANSFER SWITCH FIRE ALARM MASTER BOX FIRE FIGHTER'S PHONE CODE TRANSMITTER DRILL KEY SWITCH KEY REPOSITORY (KNOX BOX) FIRE ALARM ANNUNCIATOR PANEL, 2 LINES OF 4° CHARACTERS LCD DISPLAY FIRE ALARM CONTROL PANEL VOICE EVACUATION PANEL FIRE ALARM TERMINAL CABINET BATTERY PACK AND CHARGER AIR SAMPLING CONTROL/DETECTOR PANEL WITH ASSOCIATED AIR SAMPLING PIPING NETWORK TRANSPONDER INDIVIDUALLY ADDRESSABLE MODULE- MONITOR (PROVIDES ADDRESS FOR CONTACT) INDIVIDUALLY ADDRESSABLE MODULE- RELAY (PROVIDES CONTACT CLOSURE) CONTROL RELAY DOOR HOLDER WITH RELAY HORN AND STROBE HORN UNIT ONLY STROBE UNIT ONLY SPEAKER AND STROBE MANUAL PULL STATION SMOKE DETECTOR DUCT SMOKE DETECTOR WITH TWO AUXILIARY CONTACTS REMOTE STATION FOR DUCT DETECTOR USED AT DUCT WORK OPENING AREA TYPE SMOKE DETECTOR USED AT DUCT WORK OPENING ELEVATOR RECALL WITH AUXILIARY CONTACTS SELF CONTAINED SMOKE DETECTOR-SINGLE STATION TYPE SMOKE DETECTOR-VISUAL AND AUDIBLE SIGNAL BEAM SMOKE DETECTOR, "R"-INDICATES RECEIVER BEAM SMOKE DETECTOR, "S" INDICATES SENDING UNIT CARBON MONOXIDE DETECTOR. LINE VOLTAGE WITH BATTERY BACKUP FLAME DETECTOR AUTOMATIC HEAT DETECTOR, "R" INDICATES RATE OF RISE AUTOMATIC HEAT DETECTOR, "F" INDICATES FIXED TEMPERATURE 190°F HYDROGEN DETECTOR MOTOR OPERATED FIRE/SMOKE DUCT DAMPER WATER FLOW SWITCH, BY DIVISION 15 LOW PRESSURE SWITCH, BY DIVISION 15 TAMPER SWITCH, BY DIVISION 15 POST INDICATOR VALVE, BY DIVISION 15 END-OF-LINE RESISTOR DATA OUTLET DATA OUTLET FLOOR TYPE TELEPHONE/DATA OUTLET TELEPHONE/DATA OUTLET FLOOR TYPE TELEPHONE OUTLET TELEPHONE OUTLET-WALL MOUNTED TELEPHONE OUTLET FLOOR TYPE CALL IN SWITCH CABLE ANTENNA SYSTEM OUTLET (CATV) MASTER ANTENNA SYSTEM OUTLET (MATV) MICROPHONE OUTLET-FLOOR MOUNTED MICROPHONE OUTLET-WALL MOUNTED SPEAKER-CEILING MOUNTED SPEAKER-WALL MOUNTED SPEAKER HORN SPEAKER BI-DIRECTIONAL PAGING-WALL MOUNTED SPEAKER BI-DIRECTIONAL PAGING-CEILING MOUNTED INTERCOM UNIT-FLUSH MOUNTED MASTER INTERCOM AND DIRECTORY UNIT VOLUME CONTROL EQUIPMENT CABINET EQUIPMENT RACK-WALL MOUNTED EQUIPMENT RACK-FREE STANDING TERMINAL CABINET WITH 3/4" PLYWOOD BACKING PLYWOOD BACKBOARD CCTV CAMERA "WP" INDICATES WEATHER-PROOF EXTERIOR CAMERA CCTV COAXIAL CABLE OUTLET AND POWER OUTLET CCTV MONITOR OUTLET DOORBELL DOOR BUZZER DOOR CHIME ELECTRIC DOOR OPENER ELECTRIC DOOR STRIKE INTERCOM UNIT - FLUSH MOUNT MASTER INTERCOM AND DIRECTORY UNIT MOTION DETECTOR SECURITY DOOR ALARM MAGNETIC LOCK SECURITY CARD READER. "WP" INDICATES WEATHER-PROOF SECURITY CONTROL PANEL SECURITY DOOR CONTACTS SECURITY EXIT PUSH BUTTON SECURITY KEYPAD &AND EMT ELECTRICAL METALLIC TUBING OCP OVERCURRENT PROTECTION ∅PHASE ETR EXISTING TO REMAIN OD OUTSIDE DIAMETER, OVERFLOW DRAIN °F DEGREES FAHRENHEIT EWC ELECTRIC WATER COOLER OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED A/C AIR CONDITIONING EX EXISTING OL OVERLOAD A AMPERES FCU FAN COIL UNIT OZ OUNCE ACCU AIR COOLED CONDENSING UNIT FLR FLOOR P POLE, PHASE, PARALLEL AF AMPERE FUSE FP FIRE PUMP PE PNEUMATIC ELECTRIC AFC ABOVE FINISHED COUNTER FPVAV FAN POWERED VAV UNIT PF POWER FACTOR AFF ABOVE FINISHED FLOOR FT FOOT, FEET PH PHASE AFG ABOVE FINISHED GRADE FURN FURNACE PTAC PACKAGED TERMINAL AIR CONDITIONER AHU AIR HANDLING UNIT G GROUND, GALLONS PVC POLYVINYL CHLORIDE CONDUIT/PIPE AIC AMPERES INTERRUPTING CAPACITY GC GENERAL CONTRACTOR RCPT RECEPTACLE AL ALUMINUM GFI GROUND FAULT INTERRUPTING REV REVOLUTIONS ANSI AMERICAN NATIONAL STANDARDS INSTITUTE GFCI GROUND FAULT CIRCUIT RGS RIGID GALVANIZED CONDUIT ARCH ARCHITECT GRD GROUND RM ROOM ATS AUTOMATIC TRANSFER SWITCH GND GROUND RPM REVOLUTIONS PER MINUTE AVG AVERAGE HHWP HEATING HOT WATER PUMP RPS REVOLUTIONS PER SECOND BAS BUILDING AUTOMATION SYSTEM HOA HAND-OFF-AUTOMATIC RTU ROOF TOP UNIT B/I BYPASS ISOLATION HORIZ HORIZONTAL SF SQUARE FOOT BE BOTTOM ELEVATION HP HORSEPOWER SPEC SPECIFICATION BLDG BUILDING HR HOUR(S)SQ SQUARE BMS BUILDING MANAGEMENT SYSTEM HRTU HEATING ONLY ROOFTOP UNIT ST SHUNT TRIP BSMT BASEMENT Hz HERTZ STD STANDARD C CONDUIT IAC INSTRUMENTATIONS AND CONTROLS SW SWITCH CB CIRCUIT BREAKER ID INSIDE DIAMETER TBD TO BE DETERMINED CBA COLOR BY ARCHITECT IN INCH, INCHES TBI TO BE INSTALLED CCW COUNTERCLOCKWISE INT INTERIOR TBR TO BE REMOVED CH CHILLER JP JOCKEY PUMP TC TEMPERATURE CONTROLS CHWP CHILLED WATER PUMP K KELVIN, KEYED TCC TEMPERATURE CONTROLS CONTRACTOR CLG CEILING kW KILOWATT TR TAMPER RESISTANT CMT CONDUIT EMPTY KVA KILOVOLT AMPS TEMP TEMPERATURE COMPR COMPRESSOR LBS POUNDS TF TRANSFER FAN COND CONDENSER LSI, LSIG TRIP TYPE - LONG, SHORT, INSTANTANEOUS, GROUND FAULT TRANS TRANSITION CONV CONVECTOR LTG LIGHTING TYP TYPICAL CT COOLING TOWER MAX MAXIMUM UH UNIT HEATER CU CONDENSING UNIT, COPPER MC MECHANICAL CONTRACTOR UON UNLESS OTHERWISE NOTED CUH CABINET UNIT HEATER MCA MINIMUM CIRCUIT AMPS UV UNIT VENTILATOR CUV CLASSROOM UNIT VENTILATOR MCC MOTOR CONTROL CENTER V VOLTS CW CLOCKWISE MFR MANUFACTURER VAV VARIABLE AIR VOLUME CWP CONDENSER WATER PUMP MIN MINIMUM VB VACUUM BREAKER D DEDICATED CIRCUIT MISC MISCELLANEOUS VERT VERTICAL DC DIRECT CURRENT MOP MAXIMUM OVERCURRENT PROTECTION VF VENTILATION FAN DS DISCONNECT SWITCH MTD MOUNTED VFD VARIABLE FREQUENCY DRIVE DWH DOMESTIC WATER HEATER MV MEDIUM VOLTAGE W WIRE, WATT DWG DRAWING NA NOT APPLICABLE WP WEATHERPROOF EA EACH NEC NATIONAL ELECTRIC CODE W/ WITH EC ELECTRICAL CONTRACTOR NIC NOT IN CONTRACT W/O WITHOUT EF EXHAUST FAN NL NIGHT LIGHT WSHP WATER SOURCE HEAT PUMP EFF EFFICIENCY NOM NOMINAL EL ELEVATION NTS NOT TO SCALE SINGLE POLE SWITCH SWITCH (EDIT AS NEEDED FOR 2-WAY, 3-WAY, a SWITCH LEG ETC. SWITCH (EDIT AS NEEDED FOR 2-WAY, 3-WAY, OR a SWITCH LEG ETC. CIRCUIT BREAKER SWITCH SINGLE POLE/DOUBLE THROW SWITCH GLOW SWITCH TOGGLE, GLOWS IN OFF POSITION HORIZONTALLY MOUNTED-WITH ON POSITION TO THE LEFT KEY OPERATED SWITCH KEY OPERATED SWITCH WITH PILOT LIGHT ON WHEN SWITCH IS ON LOW VOLTAGE SWITCH LOW VOLTAGE MASTER SWITCH MOMENTARY CONTACT SWITCH SWITCH WITH PILOT LIGHT ON WHEN SWITCH IS ON TIMER SWITCH WEATHERPROOF SINGLE POLE SWITCH DIMMER SWITCH. RATED 1000W, UNLESS OTHERWISE INDICATED. "LV" = LOW VOLTAGE "FL" = FLUORESCENT OCCUPANCY SENSOR, WALL MOUNTED WITH OFF-AUTO OVERRIDE SWITCH OCCUPANCY SENSOR, CEILING MOUNTED, "P"- INDICATES MULTIPLE SWITCHES WIRED IN PARALLEL OCCUPANCY SENSOR, CEILING MOUNTED, "N"- INDICATES NETWORKED DEVICE. CUSTOMER METER DEMAND METER (UTILITY) WATTHOUR METER (UTILITY) SINGLE CONVENIENCE RECEPTACLE DUPLEX CONVENIENCE RECEPTACLE. 20A 125V. WALL MOUNT DEVICE DOUBLE DUPLEX CONVENIENCE RECEPTACLE. DUPLEX RECEPTACLE. 20A 125V. HORIZONTAL WALL MOUNT DEVICE. SINGLE CONVENIENCE RECEPTACLE ON EMERGENCY/STANDBY CIRCUIT DUPLEX CONVENIENCE RECEPTACLE ON EMERGENCY/STANDBY CIRCUIT DOUBLE DUPLEX CONVENIENCE RECEPTACLE ON EMERGENCY/STANDBY CIRCUIT SPECIAL RECEPTACLE CLOCK HANGER OUTLET RECESSED MOUNTED 8'-0" AFF OR 8" BELOW CEILING AS INDICATED MULTI-OUTLET ASSEMBLY MULTI-OUTLET ASSEMBLY FLOOR DUPLEX CONVENIENCE RECEPTACLE. FLUSH MOUNT FLOOR BOX, ADJUSTABLE, WITH BOTH POWER AND VOICE/DATA RECEPTACLES JUNCTION BOX MOTOR PUSH-BUTTON ON/OFF PUSH-BUTTON STATION THREE FUNCTION PUSH-BUTTON SWITCH (UP/DOWN/STOP) MOTOR STARTER SWITCH TOGGLE DISCONNECT SWITCH THERMAL MOTOR SWITCH WITH HANDLE GUARD AND PADLOCK CAPABILITY, "P"-INDICATES PILOT LIGHT DISCONNECT SWITCH, UNFUSED TYPE DISCONNECT SWITCH, FUSED TYPE ENCLOSED CIRCUIT BREAKER MAGNETIC CONTACTOR MAGNETIC MOTOR STARTER COMBINATION MAGNETIC STARTER AND DISCONNECT SWITCH PHASE, NEUTRAL, GROUND PHASE, PHASE, NEUTRAL, GROUND PHASE, PHASE, PHASE, NEUTRAL, GROUND PHASE, PHASE, NEUTRAL, NEUTRAL, GROUND PHASE, PHASE, GROUND PHASE, PHASE, PHASE, GROUND HOMERUN PHASE, NEUTRAL, GROUND, HOMERUN GROUND CONNECTION 3/4"x10' COPPER GROUND ROD CAPACITOR CIRCUIT BREAKER (OPEN), "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE CIRCUIT BREAKER (ENCLOSED), "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE PRIMARY DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER. WITH CURRENT LIMITING FUSES, "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE, "zzA" INDICATES FUSE RATING CONTACT NORMALLY OPEN (NO) ("TC"-WITH TIMED CLOSING) CONTACT NORMALLY CLOSED (NC) ("TO"-WITH TIMED OPENING) CURRENT TRANSFORMER CABINET FUSED CUTOUTS, "zzA" INDICATES FUSE RATING DISCONNECT SWITCH UNFUSED DISCONNECT SWITCH AIR BREAK WITH FUSE,"zzA" INDICATES FUSED RATING FUSE, "zzA" INDICATES FUSED RATING OVERLOAD RELAY GROUNDING CONNECTION-SYSTEM AND OR EQUIPMENT KIRK KEY INTERLOCK SYSTEM LIGHTNING ARRESTER AND GROUNDING TO PROTECT ALL PHASES MOTOR AND LABEL, "3" DENOTES HORSEPOWER MOTOR OPERATOR FOR CIRCUIT BREAKERS OR SWITCH NETWORK PROTECTOR PANEL BOARD POTHEAD STRESS CONE RESISTOR SHUNT TRIP MAGNETIC STARTER WITH NEMA SIZE INDICATED GROUND FAULT CIRCUIT INTERRUPTER, PERSONNEL PROTECTION GENERATOR TRANSFORMER, DRY TYPE, UNLESS OTHERWISE INDICATED POTENTIAL TRANSFORMER, "3" INDICATES QUANTITY CURRENT TRANSFORMER, "3" INDICATES QUANTITY, "400-5A" INDICATED RATIO 3-PHASE, 3-WIRE DELTA CONNECTION CORNER GROUNDED DELTA 3-PHASE, 4-WIRE WYE CONNECTION (GROUNDED NEUTRAL) ADJUSTABLE FREQUENCY DRIVE 3 REFERENCES DETAIL NUMBER BUS DUCT OR BUS WAY WIRE WAY TRANSFER SWITCH NOTATION DESIGNATORS REFERENCE SYMBOLS LIGHTING IDENTITY SYMBOLS DISTRIBUTION IDENTITY SYMBOLS FIRE ALARM COMM IDENTITY SYMBOLS FIRE ALARM IDENTITY SYMBOLS COMMUNICATION IDENTITY SYMBOLS SECURITY IDENTITY SYMBOLS ABBREVIATIONS AND TERMS SWITCH IDENTITY SYMBOLS SWITCHBOARD METER IDENTITY SYMBOLS POWER IDENTITY SYMBOLS ONE-LINE IDENTITY SYMBOLS S S F 1 NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECTSEE E-102 REFER TO ADDITIONAL SHEET FOR CONTINUATION FLOOR PLAN OVERLAP BEYOND AREA EXTENSION PLAN A. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE APPROXIMATE. ALL LOCATIONS SHALL BE FIELD VERIFIED. B. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE - LATEST EDITION ADOPTED BY INDIANA, THE INDIANA ELECTRICAL CODE AMENDMENTS, LOCAL/MUNICIPAL CODES, AND THE AUTHORITY HAVING JURISDICTION. C.ALL CONNECTIONS TO EQUIPMENT SUBJECT TO MOVEMENT OR VIBRATION SHALL BE LIQUID TIGHT FLEXIBLE METAL CONDUIT, NOT LESS THAN 12" IN LENGTH, NOR GREATER THAN 36" IN LENGTH. D. ALL CONDUIT PENETRATIONS SHALL BE SEALED WITH APPROPRIATE CONDUIT SEALING MATERIAL. E. ALL CABLE SIZES SHALL UTILIZE COPPER CONDUCTORS. F.FIELD VERIFY LOCATIONS OF BUILDING EXPANSION JOINTS WHEN ROUTING CONDUIT. ALL CONDUITS CROSSING EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION FITTINGS. EXPANSION FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC, AND MANUFACTURER'S WRITTEN RECOMMENDATIONS. G.FEEDERS FROM PANEL BOARDS BACK TO MAIN SWITCHBOARD, BETWEEN AUTO TRANSFER SWITCHES AND THEIR SOURCES/LOADS, BETWEEN DRY-TRANSFORMERS AND THEIR SOURCES/LOADS. ARE NOT INDICATED ON THE FLOOR PLAN DRAWINGS. FEEDERS ARE PART OF THE WORK, AND SHALL BE SIZED AS INDICATED ON THE ONE LINE DIAGRAM. H.CABLE TRAY IS SHOWN ON THE PLANS. IF PORTIONS OF CABLE TRAY CANNOT BE INSTALLED DUE TO CONFLICT WITH STRUCTURE OR OTHER EQUIPMENT, THE CONTRACTOR SHALL PROVIDE (2) 4" C. WITH INSULATED BUSHINGS THAT OVERLAP 1" INTO THE TRAY TO AVOID CONFLICTS IN THESE LOCATIONS. I.HOME RUNS SHALL NOT BE COMBINED IN A RACEWAY UNLESS SHOWN ON THE CONTRACT DRAWINGS. SINGLE PHASE BRANCH CIRCUIT HOME RUNS MAY BE COMBINED AT THE CONTRACTOR'S DISCRETION NOT GREATER THAN (3) PHASE CONDUCTORS, (3) NEUTRAL CONDUCTORS, AND A GROUNDING CONDUCTOR. J. EACH SINGLE PHASE BRANCH CONDUCTOR SHALL HAVE A DEDICATED NEUTRAL BACK TO THE PANEL. K.CONDUITS 2" AND LARGER THAT PENETRATE EXTERIOR WALLS SHALL USE LINK-SEALS. L.WHERE LOW VOLTAGE (CONTROL) CABLING IS ALLOWED TO BE INSTALLED WITHOUT A RACEWAY, IT SHALL BE SUPPORTED PER SECTION 260523 NOT EXCEEDING INTERVALS OF 48 INCHES, AND NOT MORE THAN 6 INCHES FROM CABINETS, BOXES, FITTINGS, OUTLETS, RACKS, FRAMES AND TERMINALS. A a 2 DRAWING MODULE LOCATION (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) GRAPHIC SCALENUMERIC SCALE NORTH ARROW SECTION LOCATION IN DRAWING MODULE SECTION LOCATION AT SUBSET SHEET PLAN BEYOND AREA EXTENSION DETAIL LOCATION IN DRAWING MODULE DETAIL LOCATION AT SUBSET SHEET LARGE SCALE VIEW LOCATION IN DRAWING MODULE LARGE SCALE VIEW LOCATION AT SUBSET SHEET REVISION CLOUD REVISION INDICATOR 11 1 KEYNOTE INDICATORS AREA LEADER LINE LEADER POINT LEADER NUMERICAL CHARACTER RELATES TO ITEM CLNG. WALL CLNG. WALL CLNG. WALL A1 M P M N H S F S GFCI DUPLEX CONVENIENCE RECEPTACLE GFCI MOUNT CENTER 6" ABOVE TOP OF COUNTERTOP BACKSPLASH DUPLEX MOUNT CENTER 6" ABOVE TOP OF COUNTERTOP BACKSPLASH FIRE ALARM RELAYR SMOKE DAMPER REMOTE INDICATORRI DOORBELL PUSH BUTTON OVERRIDE SHUTOFF SWITCHS DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc E-000 08/27/18 Electrical Symbols, Schedules and Abbreviations 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 928-1333 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NO. DATE DESCRIPTION 1 08/27/2018 Issued for Construction 7 05/15/2019 Revision 10 17 10/28/2019 Revision 19 17