E-502-Electrical-Details-Rev.5
C CONTROL SVT 1. ALL EQUIPMENT SHOWN DARK IS TO BE PROVIDED AND INSTALLED. 2. ALL EQUIPMENT SHOWN LIGHT IS BY ELECTRICAL CONTRACTOR. 3. SHOULD THE FREEZER EQUIPMENT CONTRACTOR PROVIDE A FREEZER UNIT MANUFACTURER THAT REQUIRED ADDITIONAL CONDUIT AND WIRING THAN SHOWN, THE COST FOR SUCH WORK SHALL BE THE RESPONSIBILITY OF THE FREEZER EQUIPMENT CONTRACTOR. NOTES: 208V, FREEZER POWER FEED PER EQUIPMENT CABLE AND CONDUIT SCHEDULE 240V, 2P FUSED DISCONNECT SWITCH TO 208/120V PANEL PER PLANS EVAPORATOR EQUIPMENT (THERMOSTAT, SOLENOID VALVE, DRAIN HEATER AND AND TERMINAL BLOCK BY FREEZER MFR). WIRING. 4#10, #10G., 3/4"C OR AS SUGGESTED BY MANUFACTURER EVAPORATOR EQUIPMENT (THERMOSTAT, SOLENOID VALVE, DRAIN HEATER AND AND TERMINAL BLOCK BY FEEDER MFR). WIRING. DOUBLE DUPLEX RECEPTACLE IN FLUSH MOUNTED 4" OR 4-11/16" SQUARE BOX WITH SINGLE-GANG PLASTER RING. MOUNT AT +20" AFF TO TOP. DUPLEX RECEPTACLE IN FLUSH MOUNTED 4" OR 4-11/16" SQUARE BOX WITH SINGLE-GANG PLASTER RING. MOUNT AT +20" AFF TO TOP. CONDUIT STUBBED TO NEAREST CABLE TRAY ON SAME FLOOR AS OUTLET. SEE OUTLET DETAILS ON E501 FOR CONDUIT SIZES. FACEPLATE. FLUSH MOUNTED, 3" DEEP, 4" OR 4-11/16" SQUARE BOX. PROVIDE WITH DOUBLE-GANG PLASTER RING IN GYPSUM BOARD OR PLASTER FINISHED WALL. PROVIDE 3-1/2 INCH DEEP MASONRY BOX IN MASONRY WALL.MAX.HEIGHT 5 3/4""FS" BOX WITH STAINLESS STEEL COVER PLATE AS REQ'D. THREADLESS CONNECTOR FINISHED FLOOR THREADLESS CONNECTOR COUPLING BUILDING STRUCTURE J BRANCH CIRCUIT CONDUIT DOWN TO OUTLET WALL OUTLET LAY-IN TYPE CEILING BRANCH CIRCUIT CONDUITJUNCTION BOX STRUCTURE DANIEL WOODHEAD (RECEPT.) 3000 WITH (2) DUPLEX RECEPTACLES OR EQUAL. 3#12 TYPE SO CABLE CABLE GRIP (KELLEMS OR EQUAL) J-BOX (2) 1/2" RODS MTD. AT +78" A.F.F. STEEL JOIST OR BEAMS TIE WIRE LAY-IN CEILING LAY-IN CEILING CHANNELS ADDITIONAL ROD OR WIRE SUPPORT 1/FIXTURE. ADJUSTABLE SUPPORT BRACKET, 2/FIXTURE (ATTACH TO CEILING CHANNELS) FIXTURE CEILING T-BAR CEILING STRUCTURE 1. LIGHTING FIXTURES SHALL BE SUPPORTED INDEPENDENTLY OF CEILING SYSTEM. UPONWRITTEN REQUEST TO THE ENGINEER, OTHER MEANS OF SUPPORT WILL BE CONSIDERED FOR APPROVAL. NOTE: FLEXIBLE CONDUIT DOUBLE LOOP SAFETY CHAIN MIN. 2 PER FIXTURE ANGLE IRON OR SLOTTED CHANNEL AS REQUIRED SECURELY SUPPORTED FROM STRUCTURE ABOVE CADDY CLAMPS OR EQUAL OUTLET BOX & SUPPORT ROD LAY-IN TYPE FIXTURE J F CONTROL C SVT 1. ALL EQUIPMENT SHOWN DARK IS TO BE PROVIDED BY DIVISION 26. 2. ALL EQUIPMENT SHOWN LIGHT IS BY OTHER DIVISION. 3. SHOULD THE COOLER EQUIPMENT CONTRACTOR PROVIDE A COOLER UNIT MANUFACTURER THAT REQUIRES ADDITIONAL CONDUIT AND WIRING THAN SHOWN, THE COST FOR SUCH WORK SHALL BE THE RESPONSIBILITY OF THE COOLER EQUIPMENT CONTRACTOR. NOTES: 208V, 2P COOLER POWER FEED PER EQUIPMENT CABLE AND CONDUIT SCHEDULE 240V, 2P FUSED DISCONNECT SWITCH (BY COOLER MFR.) TO 208/120V PANEL PER PLANS 4#10, #10G., 3/4"C OR AS SUGGESTED BY MANUFACTURER 2#10, #10G., 3/4"C. JUNCTION BOX EVAPORATOR MOTOR(S) BY COOLER MFR. THERMOSTAT AND SOLENOID VALVE BY COOLER MFR. TO 208/120V PANEL PER PLANS PHOTO-CONTROL 20 AMP. DPST MANUAL BYPASS WITH PILOT LIGHT 120 VAC CONTROL CIRCUIT "DUSK-TO-TIMED OFF" CONTACTOR TIME SWITCH PHOTO CELL "ON" SET "OFF" TIME AS DIRECTED BY OWNER. "DUSK-TO-DAWN" CONTACTOR, MECHANICALLY HELD WITH 20A. CONTACTS - 120v.,2 WIRE CONTROL -NEMA 1 ENCLOSURE -ASCO 917 OR ACCEPTABLE EQUIVALENT T C C L1 OUTDOOR LIGHTSHN1-1L2 FACADE UP LIGHTSHN3-3L1 OUTDOOR SCONCESLN1B-23L1 OUTDOOR FANSLN1B-25LN2A-35LN2A-39L2 EXTERIOR SCONCESL2 CANOPY LIGHTSLN2B-35L2 OUTDOOR LIGHTSLN2B-37L2 OUTDOOR FANS LN2B-46L2 COVERED PORCH FANSL1 OUTDOOR PENDANTSLN1B-42LN2B-48L2 OUTDOOR PENDANTSPHOTO-CONTROL 20 AMP. DPST MANUAL BYPASS WITH PILOT LIGHT 120 VAC CIRCUIT "DUSK-TO-TIMED OFF" CONTACTOR TIME SWITCH PHOTOCELL "ON" SET "OFF" TIME AS DIRECTED BY OWNER. "DUSK-TO-DAWN" CONTACTOR, MECHANICALLY HELD WITH 20A. CONTACTS - 120v.,2 WIRE CONTROL -NEMA 1 ENCLOSURE -ASCO 917 OR ACCEPTABLE EQUIVALENT T C C LEVEL 1 EXTERIOR EGRESS LIGHTSHLR1-16LEVEL 2 CANOPY LIGHTSHLR2-8L1 OUTDOOR LIGHTINGLLR1-3LLR1-7L1 OUTDOOR LIGHTINGLEVEL 1 EXTERIOR EXIT SIGNSHLR1-18LEVEL 2 OUTDOOR DINING LIGHTSHLR2-7DUCT/PIPE 1/2" GAP AROUND ENTIRE PERIMETER FRAME OPENING WITH STUDS PROVIDE BEAD OF NON- HARDENING CAULK AIR GAP TO BE STUFFED WITH FIBERGLASS INSULATION PARTITION, AS SCHEDULED DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc E-502 08/27/18 Electrical Details 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 928-1333 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NOT TO SCALE Freezer Wiring Diagram1 NOT TO SCALE Typical Flush Mounted Double Duplex Outlet5 NOT TO SCALE Typical Flush Mounted Duplex Outlet6 NOT TO SCALE Typical Flush Mounted Systems Outlet7 NOT TO SCALE Kitchen Waterproof Pedestal Receptacle12 NOT TO SCALE Overhead Feed to Interior Wall8 NOT TO SCALE Pendant Receptacle9 NOT TO SCALE Lay-In Ceiling Exit Sign Mounting10 NOT TO SCALE Lay-In Fixture Support11 NOT TO SCALE Cooler Wiring Diagram4 NOT TO SCALE Lighting Contractor LC-N2 NOT TO SCALE Lighting Contractor LC-LR3 NOT TO SCALE Duct/Pipe Penetration Detail13 NO. DATE DESCRIPTION 1 08/27/2018 Issued for Construction 8 05/31/2019 Revision 12 8