Loading...
HomeMy WebLinkAboutE-503-Electrical-Details-Rev.3277V CIRCUIT H N BLACK WHITE RED RED NORMAL LIGHTING LOAD CONTROL UNIT RED BLACK BLUE BLUEBLKREDBLUEBLKREDOCCUPANCY SENSOR(S) QUANTITY AS REQUIRED 277V CIRCUIT 1 CONTROL UNIT BLACK WHITE RED RED RED BLACK BLUE BLUEBLKREDSWITCH LEG (N/C)NORMAL LIGHTING LOAD BLUEBLKREDOCCUPANCY SENSOR(S) QUANTITY AS REQUIRED UL924 EMERGENCY RELAY H N 277V CIRCUIT 2 N H RED RED EMERGENCY LIGHTING LOAD SWITCH LEG (N/C) N H 277V CIRCUIT 1 H N CONTROL UNIT BLACK WHITE RED RED RED BLACK BLUE SWITCH LEG (N/C)NORMAL LIGHTING LOAD BLUEBLKREDBLUEBLKREDOCCUPANCY SENSOR(S) QUANTITY AS REQUIRED UL924 EMERGENCY RELAY 277V CIRCUIT 2 N H H N RED RED SWITCH LEG (N/C)EMERGENCY LIGHTING LOAD ADDITIONAL RELAY 120V CIRCUIT 1 H N RED RED DECORATIVE LIGHTING LOAD SWITCH LEG (N/C) 277V CIRCUIT 1 N H BLACK WHITE RED RED CONTROL UNIT RED BLACK BLUE 277V CIRCUIT 2 N H H N RED RED NORMAL LIGHTING LOAD SWITCH LED (N/C) UL 924 EMERGENCY RELAY SWITCH LEG (N/C) EMERGENCY LIGHTING LOAD BLUEBLKREDBLUEBLKREDOCCUPANCY SENSOR(S) QUANTITY AS REQUIRED CONTROL UNIT 277V CIRCUIT 1 N H BLACK WHITE RED RED RED BLACK BLUE NORMAL LIGHTING LOAD BLUEBLKREDBLUEBLKREDOCCUPANCY SENSOR(S) QUANTITY AS REQUIRED 5' J-BOXAP 16" CAT 6 FURNISHED AS PART OF THE LOW VOLTAGE DRAWINGS SHOW FOR REFERENCE ONLY. T.V RECEPTACLES 1" C. 1" C.1" C. 1 - CAT 6 TO NEAREST IDF RACK. CL 14" 12" 15" J-BOX 43" CL DOCK LEVELER PIT DOCK LEVELER PIT 48" VERIFY J-BOX -CORE DRILL HOLE THRU WALL FOR CONNECTION TO OUTSIDE CAUTION SIGN DOCK LEVELER CONTROL UNIT BY OTHERS INSTALLED BY E.C. PUSH BUTTON UNIT BY OTHERS INSTALLED BY E.C. 4-PLEX RECEPTACLE AT +48" A.F.F. DATA OUTLET EXTEND 3/4"FC TO 6" ABOVE CEILING STRUCTURE J-BOX OUTSIDE CAUTION SIGN J-BOX DOCK LEVELER CONTROLS & COMMUNICATION INSIDE LIGHTS RED BLUE BLACK BLACK BLUE RED OUTSIDE LIGHTS WIRE NUT RED GREEN AC AC MERCURY SWITCH PROXIMITY SWITCH COMMON GREEN RED WHITE (ORANGE)BLACKBROWN BLUE REDGREEN (BLUE)BLUEBLUE12V ACBLACK WHITE GREEN MERCURY SWITCH PROXIMITY SWITCH 12V ACFINISHED FLOOR FINISHED FLOOR 1 2 3 4 5 4 5 3 2 1 1'-0" GRADEROAD ANCHOR BOLTS AT LENGTH RECOMMENDED BY MANUFACTURER ROUND CONCRETE BASE BY E.C.2"2'-0"2'-0" PROVIDE LEVEL SURFACE FOR INSTALLATION INTEGRAL J-BOX PROVIDE MIN. 6" OF PEA GRAVEL FOR DRAINAGE LED IN-GRADE UP-LIGHT CONCRETE BASE DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc E-503 08/27/18 Electrical Details 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 928-1333 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NOT TO SCALE Vac Sensor1 NOT TO SCALE Vacancy Sensor Diagram Normal and Emergency2 NOT TO SCALE Vac Sensor Diagram Normal Em and Decorative Its3 NOT TO SCALE Occupancy Sensor Normal and Emergency4 NOT TO SCALE Occupancy Sensor Diagram with Override5 NOT TO SCALE Guestroom Comunication Diagram6 NOT TO SCALE Dock Leveler Detail7 NOT TO SCALE Light Bollard Detail8 NOT TO SCALE Ingrade Uplight9 NO. DATE DESCRIPTION 1 08/27/2018 Issued for Construction 8 05/31/2019 Revision 12