Loading...
HomeMy WebLinkAboutEL103-Lighting-Reflected-Ceiling-Plan-Level-3-Rev.95 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 D D F F J J L L P P T T 1 1 Y Y U U A A 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE G G XX SS VV 2 23 3 10 10 22 22 24 24 B B QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 0.9 0.9 6.7 6.7 EX31 EX31 5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 D D F F J J L L P P T T 1 1 Y Y U U A A 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE G G XX SS VV 2 23 3 10 10 22 22 24 24 B B QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 0.9 0.9 6.7 6.7 GUESTROOM KING STUDIO 310GUESTROOM KING STUDIO 311 CORRIDOR 303 ADA GUESTROOM LUXURY SUITE B 312 GUESTROOM QQ 314 GUESTROOM KING 316 GUESTROOM KING 318 GUESTROOM KING 319 GUESTROOM KING 320 ELEVATOR LOBBY 308 FITNESS 310 GUESTROOM KING 313 MECH 304 STAIR #1 3ST1 CORRIDOR 302 HOUSEKEEPING 307 ELEC 306 GUESTROOM KING 327 GUESTROOM KING 329 GUESTROOM KING 331 GUESTROOM KING 333 GUESTROOM KING 335 GUESTROOM KING 337 GUESTROOM JUNIOR SUITE W/ ADA COMM. 339 STAIR #2 3ST2 VEST 305 CORRIDOR 301 GUESTROOM QQ 340 GUESTROOM QQ W/BALCONY 338GUESTROOM KING 336 GUESTROOM KING 334 ADA GUESTROOM KING W/ ADA COMM. 332 GUESTROOM KING 330 GUESTROOM KING 328 GUESTROOM KING 326 GUESTROOM KING 325GUESTROOM KING 324 GUESTROOM KING 323 GUESTROOM QQ W/ ADA COMM. 322 GUESTROOM LUXURY SUITE A 321 CORRIDOR 301 E-405 1 1 1 A A LN3C LN3B LN3A E-4063 E-406 2 E-406 1 L38 HLR3 - 2 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L38 HLR3 - 2 L38 HN3 - 1 1 X1 HLR3 - 7 X1 HLR3 - 7 L4 L4 X1 HLR3 - 2 X1 HLR3 - 2 X2 HLR3 - 7X2 HLR3 - 7 5 5 5 5 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 L14 HN3 - 1 1 1 1 L2 HN3 - 1 1 1 1 1 1 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L14 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 L15 HN3 - 1 1 18 18 A B 18 A B 18 A B A B 18 181818 18 18 1818 18 18 18 J B A A A B A 1 1 1 BB A B AAAAA B B A BB A A B 18 A B B A A B A B18 18 18 18 18 A B B B B A A A B A A A 4 J 1 1 B B A A 1 BA 4 1 1J X1 HLR3 - 7 AA AA A AAAA AA AAAAAAA 6 A A 6 6 6 6 AA A A A A 18 7 77777 X1 HLR3 - 77 7 7 7 7 7 7 7 8888 18 1818 8 LN3A-338 LN3A-368 LN3A-398 LN3A-428LN3A-458LN3A-488 8 A 4 1 1 X1 HLR3 - 2 8 LN3C-14 8 LN3C-17 8 LN3C-49 8 LN3C-24 8 LN3C-29 8 LN3C-32 8 LN3B-23 8 LN3B-26 8 LN3C-27 8 LN3B-56 8 LN3B-37 8 LN3B-34 LN3A-18LN3A-21LN3A-24LN3A-27LN3A-30LN3B-208LN3B-17 LN3B-498 BB LN3B-458 LN3B-428 LN3B-408 L26 HN3 - 4 L26 HN3 - 4 L26 HN3 - 4 L26 HN3 - 4 L26 HN3 - 4L26 HN3 - 4 NL NL 9 99 9 9 NL NL L25 HN3 - 3 L25 HN3 - 3 L25 HN3 - 3 L25 HN3 - 3 L25 HN3 - 3 L25 HN3 - 3 L25 HN3 - 3 L25 HN3 - 3 L25 HN3 - 3 L25 HN3 - 3 L25 HN3 - 3 LN3B - 59 LN3B - 60 LN3B - 61 LN3B - 60 LN3A - 62 LN3A - 62 LN3A - 61 LN3A - 61 LN3B - 61 7 7 10 101010 10 10 10 10 10 9 9 9 9 9 9 9 9 9 11 11 11 11 11 NL NL L26 HN3 - 4 9 11 L26 HN3 - 4 9 11 LN3C - 54 LN3C - 54 1 B 7 12 12121218 12 12 12 12 12 12 12 13 131312121212 12 13 1212 12 L38 HN3 - 1 12 12 12 12 12 13 141514151415141514151415 14151415 1415 14 15 141514 15 14 15 14151415141514151415 AA B 15 14 1415 4 14 15 14 15 14 15 14 15 14 15 14 15 14 15 A A 14 15 1 8 LN3C-55 14 15 J 16 C 16 C 8 LN3B-65 17 A A A A 6 6 A A 6 6 A A 6 6 A A 6 6 A A 6 6 A A 6 6 A A 6 6 A A 6 A 6 A A 6 6 A A 6 A 6 A 6 6 A A L4 L4 X1 HLR3 - 2 L2B HN3 - 1 4 J 17 B B F 2 10 9 L25 HN3 - 3 L3 HN3 - 1 L3 HN3 - 1 L3 HN3 - 1 1 A B B 1 F 2 JJ 4 1 A 1 1 X1 HLR3 - 7 19 19 19 19 W1 HN3 - 3 9 1 1 LLR3 HN3 HLR3 L38 HN3 - 1 L38 HN3 - 1 L38 HN3 - 1 L40 HN3-3 20 HLR3-7 HLR3-7 HLR3-7 HLR3-7HLR3-7 HLR3-7 HLR3-7 HLR3-7 HLR3-7 HLR3-7 HLR3-7 HLR3-7 HLR3-7 HLR3-2 HLR3-2 HLR3-2 HLR3-2 HLR3-2 HLR3-2 HLR3-7 X1 HLR3-7 A. SEE SHEET E-000 FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS. B. SEE E-400 SHEETS FOR ENLARGED AREA PLANS AND ELEVATIONS. C. SEE E-500 SHEETS FOR ELECTRICAL DETAILS. D. SEE E-600 SHEETS FOR LIGHTING FIXTURE SCHEDULE, LIGHTING CONTROL INTENT AND PANEL SCHEDULES. E. ALL WORK SHALL COMPLY WITH NATIONAL, STATE, AND LOCAL CODES AND ORDINANCES PERTAINING TO WORK ON THIS PROJECT. F. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. G. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE-RATED PARTITIONS, CABINET, CASEWORK, AND BUILT IN DETAILS. H. ALL LIGHTING AND LIGHTING CONTROLS ON THE PROJECT WILL BE IN ACCORDANCE WITH MARRIOTT AUTOGRAPH COLLECTION BRAND STANDARDS. I. EMERGENCY LIGHTING SHOWN ON THIS DRAWING INDICATES CODE REQUIRED EMERGENCY LIGHTING FED FROM THE `LEGALLY REQUIRED BRANCH' OF THE ESSENTIAL ELECTRICAL SYSTEM. J. LABEL ALL RELAYS AND POWER SUPPLIES (ON THE DEVICE OR ON THE BOX THEY ARE CONNECTED TO) WITH THE AREA THE DEVICE SERVES, THE BRANCH CIRCUIT IT CONTROLS, AND THE DEVICE ADDRESS (IF APPLICABLE). K. EXIT SIGNS MOUNTED ABOVE DOORS TO BE +0'-6" ABOVE FINISHED DOOR FRAME TO BOTTOM OF FIXTURE. EXITS NOT LOCATED ABOVE DOOR TO BE MOUNTED 7'-6" AFF TO BOTTOM OF FIXTURE UNLESS OTHERWISE NOTED. L. ALL DECORATIVE FIXTURES THAT ARE CONSIDERED PLUG LOAD AND ARE NOT HARDWIRED WILL BE SHOWN ON INTERIOR FF&E DRAWINGS. M. ALL CEILING MOUNTED OCCUPANCY SENSORS LOCATED IN PUBLIC AREAS TO BE RECESSED IN CEILING ACUITY RM-PDT-9 OR ENGINEER APPROVED SUBSTITUTE. FOR AREAS WHERE CEILINGS ARE GREATER THAN 10'-0" SENSORS TO BE ACUITY RM-PDT-9-6 OR ENGINEER APPROVED SUBSTITUTE. N. ALL CEILING MOUNTED OCCUPANCY SENSORS LOCATED IN BACK OF HOUSE AREAS TO BE SURFACE MOUNTED ACUITY CM-PDT10 OR ENGINEER APPROVED SUBSTITUTE. O. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT.COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. P. WHERE MULTIPLE SWITCHES ARE ADJACENT TO EACH OTHER, GANG TOGETHER ON SINGLE FACE PLATE WITH MULTIPLE SWITCH/OUTLET. Q. ALL DECORATIVE LIGHT FIXTURES NOT INCLUDED IN LIGHT FIXTURE SCHEDULE ON SHEET E-601 TO BE INCLUDED IN FF&E BUDGET AND WILL NOT BE BID WITH ARCHITECTURAL LIGHTING PACKAGE. GENERAL SHEET NOTES DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc EL103 08/27/18 Lighting Reflected Ceiling Plan Level 3 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 928-1333 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/8" = 1'-0" Lighting Reflected Ceiling Plan Level 31 SHEET KEYNOTES 1 DECORATIVE LIGHTING FIXTURE. REFER TO INTERIOR DESIGN, FF&E AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 2 LED STRIP MOUNTED ON TOP OF CASEWORK AND ENCLOSED IN NICHE PER INTERIOR DESIGN DETAIL DRAWINGS. REMOTE POWER SUPPLY PLACEMENT TO BE COORDINATED IN FIELD. 4 LED STRIP SURFACE MOUNTED IN NICHE AT DRAPERY POCKET. SEE INTERIOR DESIGN CEILING DETAILS FOR MOUNTING INFORMATION. REMOTE POWER SUPPLY PLACEMENT TO BE COORDINATED IN FIELD.. 5 MOUNT DEVICE 7'-6" ABOVE FINISHED FLOOR. 6 SET OF (2) WALL BOX DIMMERS IN SINGLE FACEPLATE WITH FINISH PER ARCHITECT. DIMMER CLOSEST TO DOOR TO CONTROL DOWNLIGHT AND DIMMER CLOSEST TO ROOM TO CONTROL CHANDELIER. 7 PROVIDE BODINE GTD20A GENERATOR TRANSFER DEVICE (GTD) OR SUBSTITUE PRODUCT AS APPROVED BY ENGINEER FOR LIGHTING LOAD. CONNECT TO LIFESAFETY PANEL & CIRCUIT AS INDICATED PER DRAWING. 8 CONNECT LIGHT FIXTURES IN THIS ROOM TO CIRCUIT AS INDICATED. 9 DEVICE CONTROLLED BY LIGHTING SCENE CONTROLLER SC-N. SEE ELECTRICAL DETAILS FOR SCHEMATIC DIAGRAM. 10 LED UPLIGHT SURFACE MOUNTED TO FACADE TO UPLIGHT AS INDICATED PER DRAWING. FINAL PLACEMENT TO BE COORDINATED IN FIELD.. 11 HIGH LUMEN LED FLOOD AFFIXED TO SIDE OF COLUMN WITH ADJUSTABLE MOUNTING BRACKET. AIM AND FOCUS OF FIXTURE TO BE CONDUCTED WITH OWNER, ARCHITECT AND LIGHTING DESIGNER FOLLOWING INSTALLATION. 12 QUANTITY OF (2) READING LIGHTS AS SPECIFIED BY INTERIOR DESIGNER TO BE INCORPORATED INTO THE KING GUESTROOM HEADBOARD. SEE INTERIOR DESIGN DRAWINGS FOR ADDITIONAL INFORMATION. 13 QUANTITY OF (4) READING LIGHTS AS SPECIFIED BY INTERIOR DESIGENR TO BE INCORPORATED INTO THE QUEEN GUESTROOM HEADBOARD. SEE INTERIOR DESIGN DRAWINGS FOR ADDITIONAL INFORMATION. 14 TOGGLE SWITCH TO HAVE INTEGRAL LED NIGHTLIGHT. CONNECT TO LOCAL CIRCUIT. SWITCH TO BE LUTRON DIVA OR ENGINEER APPROVED SUBSTITUTE. 15 FURNISH AND INSTALL ILLUMINATED MIRROR CENTERED OVER SINK. SEE INTERIOR DESIGN DRAWINGS FOR ADDITIONAL INFORMATION. 16 LINEAR LED STRIP MOUNTED INSIDE OF CLOSET AND CONTROLLED BY DOOR CONTACT SWITCH. 17 SET OF (2) 3-WAY DIMMERS IN SAME FACEPLATE WITH FINISH PER ARCHITECT TO CONTROL DECORATIVE LIGHT FIXTURES AND ARCHITECTURAL LIGHT FIXTURES SEPARATELY. 18 DECORATIVE CHANDELIER. SEE INTERIOR DESIGN DRAWINGS FOR ADDITIONAL INFORMATION. 19 SET OF (2) WALL BOX DIMMERS IN SINGLE FACEPLATE WITH FINISH PER ARCHITECT. DIMMERS TO CONTROL DECORATIVE AND ARCHITECTURAL LIGHTING SEPARATELY. 20 PROVIDE (1) RUN OF TYPE L40 LED TAPE IN NICHE AT TOP AND BOTTOM OF ENTRY SIGNAGE. EACH RUN TO BE 9'-9-1/4" IN LENGTH. REMOTE POWER SUPPLY PLACEMENT TO BE COORDIANTED. SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION. 0 16'8'4' N REVISIONS NO. DATE DESCRIPTION 1 08/27/2018 Issued for Construction 6 03/22/2019 Revision 8 11 08/02/2019 Revision 15 17 10/28/2019 Revision 19 19 11/14/2019 Revision 21 21 01/08/2020 RFI 217 21