Loading...
HomeMy WebLinkAboutEL107-Lighting-Reflected-Ceiling-Plan-Level-7-Rev.3JJJ J 5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 L L 1 1 U U 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE XX SS VV 2 23 3 10 10 22 22 24 24 QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 6.7 6.7 EX31 EX31 5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 D D F F J J L L P P T T 1 1 Y Y U U A A 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE G G XX SS VV 2 23 3 10 10 22 22 24 24 B B QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 6.7 6.7 MECHANICAL 702 STAIR #2 7ST2 L4 L4 L2 HLR7 - 7 L2 HN7 - 3 L2 HN7 - 3 L2 HN7 - 3 L2 HN7 - 3 L2 HN7 - 3 L2 HN7 - 3 L2 HN7 - 3 L2 HN7 - 3 1 1 3 1 1 A A W1 HN7 - 2 W1 HN7 - 2 W1 HN7 - 2 E-406 2 W1 HN7 - 2 W1 HN7 - 2 L27 L27L27 4 4 4 4 HN7 - 1 HN7 - 1 HN7 - 1 NL NL 3 L27 HN7 - 1 2 2 2 2 3WP3 WP 4 HLR7 HDPN7 L2 HLR7 - 7 L2 HN7 - 3 LN7 HN7 HLR7-7 HLR7-7 21 21 NL NL A. SEE SHEET E-000 FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS. B. SEE E-400 SHEETS FOR ENLARGED AREA PLANS AND ELEVATIONS. C. SEE E-500 SHEETS FOR ELECTRICAL DETAILS. D. SEE E-600 SHEETS FOR LIGHTING FIXTURE SCHEDULE, LIGHTING CONTROL INTENT AND PANEL SCHEDULES. E. ALL WORK SHALL COMPLY WITH NATIONAL, STATE, AND LOCAL CODES AND ORDINANCES PERTAINING TO WORK ON THIS PROJECT. F. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. G. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE-RATED PARTITIONS, CABINET, CASEWORK, AND BUILT IN DETAILS. H. ALL LIGHTING AND LIGHTING CONTROLS ON THE PROJECT WILL BE IN ACCORDANCE WITH MARRIOTT AUTOGRAPH COLLECTION BRAND STANDARDS. I. EMERGENCY LIGHTING SHOWN ON THIS DRAWING INDICATES CODE REQUIRED EMERGENCY LIGHTING FED FROM THE `LEGALLY REQUIRED BRANCH' OF THE ESSENTIAL ELECTRICAL SYSTEM. J. LABEL ALL RELAYS AND POWER SUPPLIES (ON THE DEVICE OR ON THE BOX THEY ARE CONNECTED TO) WITH THE AREA THE DEVICE SERVES, THE BRANCH CIRCUIT IT CONTROLS, AND THE DEVICE ADDRESS (IF APPLICABLE). K. EXIT SIGNS MOUNTED ABOVE DOORS TO BE +0'-6" ABOVE FINISHED DOOR FRAME TO BOTTOM OF FIXTURE. EXITS NOT LOCATED ABOVE DOOR TO BE MOUNTED 7'-6" AFF TO BOTTOM OF FIXTURE UNLESS OTHERWISE NOTED. L. ALL DECORATIVE FIXTURES THAT ARE CONSIDERED PLUG LOAD AND ARE NOT HARDWIRED WILL BE SHOWN ON INTERIOR FF&E DRAWINGS. M. ALL CEILING MOUNTED OCCUPANCY SENSORS LOCATED IN PUBLIC AREAS TO BE RECESSED IN CEILING ACUITY RM-PDT-9 OR ENGINEER APPROVED SUBSTITUTE. FOR AREAS WHERE CEILINGS ARE GREATER THAN 10'-0" SENSORS TO BE ACUITY RM-PDT-9-6 OR ENGINEER APPROVED SUBSTITUTE. N. ALL CEILING MOUNTED OCCUPANCY SENSORS LOCATED IN BACK OF HOUSE AREAS TO BE SURFACE MOUNTED ACUITY CM-PDT10 OR ENGINEER APPROVED SUBSTITUTE. O. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT.COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. P. WHERE MULTIPLE SWITCHES ARE ADJACENT TO EACH OTHER, GANG TOGETHER ON SINGLE FACE PLATE WITH MULTIPLE SWITCH/OUTLET. Q. ALL DECORATIVE LIGHT FIXTURES NOT INCLUDED IN LIGHT FIXTURE SCHEDULE ON SHEET E-601 TO BE INCLUDED IN FF&E BUDGET AND WILL NOT BE BID WITH ARCHITECTURAL LIGHTING PACKAGE. GENERAL SHEET NOTES DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc EL107 08/27/18 Lighting Reflected Ceiling Plan Level 7 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 928-1333 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/8" = 1'-0" Lighting Reflected Ceiling Plan Level 710 16'8'4' SHEET KEYNOTES 1 MOUNT FIXTURE 7'-6" AFF TO BOTTOM OF FIXTURE. 2 LINEAR LED FLOOD IN EXTRUSION WITH 10X60 DISTRIBUTION SURFACE MOUNTED INSIDE BASE OF PEDIMENT. 3 SURFACE MOUNT FIXTURES TO UNDERSIDE OF STRUCTURE. 4 MOUNT FIXTURE +9'-6" ABOVE FINSIHED FLOOR TO BOTTOM OF FIXTURE. N NO. DATE DESCRIPTION 1 08/27/2018 Issued for Construction 6 03/22/2019 Revision 8 21 01/08/2020 RFI 217