Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EP101-Power-Floor-Plan-Level-1-Rev.8
DWUP TT TT TTTT T TTTTTTT T TTT T T 24" x 42"24" x 36"24" x 42"18" x 42"18" x 42"18" x 48"18" x 36"18" x 42"18" x 48"24" x 36"24" x 36"24" x 36"18" x 42"18" x 42"18" x 42"18" x 48"14" x 60"18" x 30"18" x 36"18" x 30"18" x 48" 18" x 48" 18" x 48" 21" x 48"21" x 42"24" x 42" 24" x 36" 24" x 60" 24" x 42" SB J J J J SCPSCP J J 5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 D D F F J J L L P P T T 1 1 Y Y U U A A 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE G G XX SS VV 2 23 3 10 10 22 22 24 24 B B QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 0.9 0.9 6.7 6.7 TN1 LDPN1 HDPN ATS-LRLLR1 TLR1 CORRIDOR 121 HR 126 MDF 123 BREAK ROOM 125 CLEAN 127 SALES 129 SOILED 128 SALES 130 HOLDING 132 SECURITY 133 CORRIDOR 120 ELEVATOR LOBBY 108 RESTAURANT & BAR 145 COVERED DINING 146 HOTEL KITCHEN 140 RECYCLING 153 CAN 154STAIR #1 1ST1 PRIVATE DINING 152 VESTIBULE 150 VESTIBULE 144 MONON ENTRY 143 MEN 103 WOMEN 104 RAMP 105 VESTIBULE 106 MONON LOBBY 102 RECEPTION 109 PRIVATE DINING 111 FEINSTEIN'S CLUB 110 SERVICE 136 JANITOR 137 WOMEN'S LOCKER 135 MEN'S LOCKER 134 GREEN 115 SERVICE 114 CORRIDOR 122 CLUB OFFICE 119 VESTIBULE 113 OFFICE 117 CHEM 159 CLUB STOR 124 HOUSEKEEPING 118 STAIR #2 1ST2 DWBP-1 HN1 COATS & STORAGE 107 LN1A LN1B ELEC 156 MEETING 101 VESTIBULE 157 EMER POWER 155 FIRE PUMP 138 E-402 1 E-403 1 HK STORAGE 160 WORK 131 E-404 1 MEN 147 WOMEN 148 COLD STOR 151 UNISEX TLT 116 BAR 112 E-406 2 DRY STOR 149 CORRIDOR 139 COLLECTION 141 JAN. 158 2 2 LN1A - 60,62 LN1A - 63,65 LN1B - 55,57LN1B - 59,61 2 LN1B - 58,60 LN1A - 42 LN1A - 42 LN1A - 30 LN1A - 42 LN1B - 43 LN1B - 38LN1B - 38 LN1B - 38 LN1A - 48 LN1A - 48 LN1A - 48 LN1A - 48 LN1A - 44 LN1A - 44 LN1A - 44 LN1A - 44 LN1A - 45 LN1A - 45 LN1A - 45 LN1A - 45 LN1A - 35 LN1A - 53 LN1A - 53 LN1A - 47 LN1A - 53 LN1A - 53 LN1A - 51 LN1B - 43 LN1A - 51 LN1B - 43 LN1B - 5 LN1B - 5 LN1A - 17 LN1A - 9 LN1A - 10 LN1A - 34LN1A - 34 LN1B - 33 LN1B - 31 LN1B - 12 LN1B - 37 LN1B - 37 LN1B - 12 LN1B - 12 LN1B - 12 LN1B - 41 LN1B - 41 LN1A - 43 LN1A - 43 LN1A - 40 LN1A - 40 LN1A - 40 LN1A - 51 LN1A - 46 LN1A - 46 LN1A - 46 LN1A - 46 LN1A - 32 LN1A - 32 LN1A - 49 LN1A - 49 LN1B - 11 LN1B - 5 LN1B - 37 LN1A - 51 LN1A - 51 LN1A - 49 LN1A - 33 LN1A - 47 LN1B - 25 2 LN1B - 34 2 HLR1 2 4 4HN1 - 8,10,122 5 5 FP-1 7 LN1B - 11LN1B - 11 JOCKEY PUMP LN1B - 52,54 2 2 2 LN1B - 12 LN1B - 1 10 LN1B - 39LN1B - 39 LN1B - 39 LN1B - 39 LN1B - 46 LN1B - 46 LN1B - 46 LN1B - 46 LN1B - 32 LN1B - 32 1 LN1B - 11 2 LN1A - 36 LN1A - 36 LN1A - 39 LN1A - 39 8 8 8 88 8 8 2 LN1A - 47 LN1A - 47LN1A - 53 9 10 10 88 8 1 LN1A - 49 LN1A - 35 LN1A - 33 2 LN1B - 41 2 8 LN1A - 1 LLR1 - 4 LLR1 - 1 11 11 12 HN1 - 5,7,9 LN1A - 56,58 LLR1 - 11 LLR1 - 3 LLR1 - 9 LN1B - 48,50 10 LN1A - 27,29 LN1A - 23,25 14 15 16 LN1A - 43 HLR1 - 8,10,12 LN1A - 26,28 LN1B - 2 17 FACP LLR1 - 1 11 LN1B - 5 LN1B - 12 LN1B - 12 2 2 EWH-3 EWH-2 LN1B - 51,53 LN1B - 66,68 EWH-1 LN1B - 62,64 EDH-1-01HN1 - 13,15,17 FCU-1-1 FCU-1-3 LN1B - 27,29 EWH-4 FCU-1-19 FCU-1-18 FCU-1-20 FCU-1-22 EDH-1-22 FCU-1-21EDH-1-21 EAC-1 EUH-1 EUH-2 EF-1 EPUH-1 EWH-5 LN1A - 19,21 HN1 - 14,16,18 HN1 - 19,21,23 LN1A - 13,15 LN1A - 7 FCU-1-4 FCU-1-8 FCU-1-17 FCU-1-5 FCU-1-2 FCU-1-6 FCU-1-7 FCU-1-14FCU-1-12 FCU-1-15FCU-1-16 DS-1 DS-2 EWH-6 DS-3 EWH-7 FCU-1-13 FCU-1-9 FCU-1-10 FCU-1-11 EWH-8 HN1 - 20,22,24 LN1B - 22,24 LN1B - 21,23 EWH-14 LN1B - 26,28 LN1A - 12,14 LN1B - 47,49 19 4 TNK 20 LN1B - 12 BSB-2-2B BSB-1-1C BSB-1-1B BSB-1-1A LN1B - 1 6 A. SEE SHEET E-000 FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS. B. SEE E-400 SERIES SHEETS FOR ENLARGED PLANS. C. SEE E-500 SERIES SHEETS FOR ELECTRICAL DETAILS. D. SEE E-602 FOR ELECTRICAL CONNECTIONS TO MECHANICAL AND PLUMBING EQUIPMENT SCHEDULE. E. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL INTERCONNECT WIRING FURNISHED BY OTHER TRADES INCLUDING BUT NOT LIMITED TO HVAC, PLUMBING AND KITCHEN. F. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE RAINPROOF AND WEATHER TIGHT. G. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR. USE SOLID CONDUCTOR FOR SIZE #10AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. H. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY INTERIOR DESIGNER. I. ALL RECEPTACLES AND SWITCHES SHALL BE FLUSH MOUNTED UNLESS NOTED OTHERWISE. J. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWING FOR DIMENSIONS, ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE RATED PARTITIONS, CABINET AND CASEWORK DETAILS. K. FINAL DETERMINATION OF FIRE STOPPING REQUIREMENTS SHALL BE BASED ON LOCAL CODE REQUIREMENTS. SEE ARCHITECTURAL COVER SHEET FOR ADDITIONAL INFORMATION. L. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK ON THIS PROJECT. M. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO THE BUILDING LINES. N. SEE E-800 SERIES SHEETS FOR ONE-LINE DIAGRAMS. O. SEE SHEET E-611 FOR ELECTRICAL CONNECTIONS TO KITCHEN EQUIPMENT SCHEDULE. P. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT.COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. GENERAL SHEET NOTES DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc EP101 08/27/18 Power Floor Plan Level 1 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 928-1333 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/8" = 1'-0" Power Floor Plan Level 11016'8'4' N SHEET KEYNOTES 1 MOUNT CENTER OF DEVICE +5'-0" A.F.F. VERIFY FINAL LOCATION WITH INTERIOR DESIGN DRAWINGS. 2 MOUNT CENTER OF DEVICE AT +6" ABOVE COUNTERTOP BACK SPLASH. VERIFY FINAL LOCATION WITH INTERIOR DESIGNER. 3 NOT USED. 4 EXTEND CONDUCTORS TO HEAT PUMP. 5 MOUNT CENTER OF DEVICE 12" BELOW TOP OF ELEVATOR PIT. VERIFY FINAL LOCATION IN FIELD WITH ELEVATOR INSTALLER PRIOR TO ROUGH-IN. 6 HUBBEL #CFB10G55CR FLOOR BOX WITH (3) DUPLEX RECEPTICLES AND (1) PLATE CAPABLE OF HOLDING (6) KEYSTONE MODULES SEE LOW VOLTAGE DRAWINGS FOR ADDITIONAL REQUIREMENTS. VERIFY FINAL LOCATION IN FIELD WITH INTERIOR DESIGNER PRIOR TO ROUGH-IN. 7 CONNECT TO JOCKEY PUMP. VERIFY FINAL LOCATION IN FIELD WITH SPRINKLER CONTRACTOR. 8 MOUNT CENTER OF DEVICE +4'-0" AFF. 9 FLOOR BOX BY HUBBELL #CFBSIR4CFB WITH #CFBSIR4CVRXXX COVER. FINISH SELECTION BY INTERIOR DESIGNER. 10 MOUNT RECEPTACLE HORIZONTALLY WITH CENTER OF DEVICE 6" BELOW CEILING. 11 POWER SUPPLY FOR DOOR OPERATOR. 12 DOCK LEVELER CONTROL STATION. SEE DETAIL 7 ON SHEET E-503 FOR ADDITIONAL INTORMATION. 14 ACCESS SYSTEM CONTROL PANEL. 15 CCTV SYSTEM CONTROL PANEL. 16 FIRE ALARM CONTROL PANEL. 17 IRRIGATION CONTROL PANEL. VERIFY FINAL LOCATION, ELECTRICAL CHARACTERISTICS AND TERMINATION TYPE WITH IRRIGATION SYSTEM INSTALLER PRIOR TO ROUGH-IN. 19 UNDERGROUND. (2) 4" C.& (4) 1" C. 20 FUSED DISCONNECT FOR PANEL LSK LOCATED IN HOTEL KITCHEN 140. NO. DATE DESCRIPTION 1 08/27/2018 Issued for Construction 3 12/03/2018 Revision 3 6 03/22/2019 Revision 8 7 05/15/2019 Revision 10 8 05/31/2019 Revision 12 20 12/20/2019 Revision 22