Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EP105-Power-Floor-Plan-Level-5-Rev.6
TTTTT TTT T T T T T TT T T T T T T T T T T T TTTTTTT T C C C C C CCC CCCCCC C CCC J J 5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 L L 1 1 U U 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE XX SS VV 2 23 3 10 10 22 22 24 24 QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 6.7 6.7 LN5A LDPN5LN5BHLR5HN5 LN5C LN5C - 2,4 LN5C - 6,8 LN5C - 44,46 LN5C - 5,7 LN5C - 1,3 LN5B - 2,4 LN5B - 51,53 LN5B - 9,11 LN5B - 1,3 LN5B - 5,7 LN5A - 50,52 LN5A - 9,11 LN5A - 10,12 LN5A - 5,7 LN5A - 6,8 LN5A - 1,3 LN5A - 2,4 CORRIDOR 502 E-4063 E-406 2 1 2 7 2 7 11 7 2 2 7 1 1 7 2 1 7 22 7 1 1 7 2 1 7 2 2 7 1 1 7 2 1 2 7 1 7 22 7 1 1 7 22 7 7 2 1 2 7 1 7 2 1 2 1 1 4 2 2 7 1 1 7 2 2 71 2 7 1 1 7 2 17 2 2 71 2 7 1 1 2 4 1 2 2 7 1 1 7 2 LN5C - 82,84 LN5A - 82,84 LN5A - 60 LN5A - 15LN5A - 15 LN5A - 17 LN5A - 16 LN5A - 16 LN5A - 19 LN5A - 19 LN5A - 18 LN5A - 21 LN5A - 21 LN5A - 20 LN5A - 20 LN5A - 21 LN5A - 23 LN5A - 22 LN5A - 22 LN5A - 22 LN5A - 25 LN5A - 25 LN5A - 24 LN5A - 27 LN5A - 27 LN5A - 26 LN5A - 27 LN5A - 26 LN5A - 29 LN5A - 28 LN5A - 28 LN5A - 28 LN5A - 31 LN5A - 31 LN5A - 30 LN5A - 33 LN5A - 33 LN5A - 32 LN5A - 32 LN5A - 33 LN5A - 35 LN5A - 34 LN5A - 34 LN5A - 34 LN5A - 34 LN5A - 37 LN5A - 37 LN5A - 36 LN5A - 39 LN5A - 38 LN5A - 38 LN5A - 39 LN5A - 39 LN5A - 41 LN5A - 40 LN5A - 40 LN5A - 40 LN5A - 43 LN5A - 43 LN5A - 42 LN5A - 45 LN5A - 45 LN5A - 45 LN5A - 44 LN5A - 44 LN5A - 47 LN5A - 46 LN5A - 46 LN5A - 46 LN5A - 49 LN5A - 49 LN5B - 12 LN5B - 12 LN5B - 12 LN5B - 13 LN5B - 14 LN5B - 14 LN5B - 14 LN5B - 15 LN5B - 16 LN5B - 17 LN5B - 17 LN5B - 18 LN5B - 19 LN5B - 19 LN5B - 19 LN5B - 20 LN5B - 20 LN5B - 21 LN5B - 22 LN5B - 23LN5B - 23LN5B - 22 LN5B - 22 LN5B - 24 LN5B - 25 LN5B - 25LN5B - 25 LN5B - 26 LN5B - 26 LN5B - 29LN5B - 29 LN5B - 29 LN5B - 27 LN5B - 28 LN5B - 29 LN5B - 29 LN5B - 29 LN5B - 30 LN5B - 30 LN5B - 30 LN5B - 30 LN5B - 30 LN5B - 31 LN5B - 31 LN5B - 31 LN5B - 31 LN5B - 31 LN5B - 32 LN5B - 34 LN5B - 34 LN5B - 34 LN5B - 33 LN5B - 33 LN5B - 35 LN5B - 37 LN5B - 37 LN5B - 36 LN5B - 36 LN5B - 37 LN5B - 38 LN5B - 40LN5B - 40 LN5B - 39 LN5B - 39 LN5B - 40 LN5B - 41 LN5B - 43 LN5B - 43 LN5B - 43LN5B - 42 LN5B - 42 LN5B - 44 LN5B - 46 LN5B - 46 LN5B - 45 LN5B - 45 LN5B - 46 LN5B - 47 LN5B - 49 LN5B - 48 LN5B - 48 LN5B - 49 LN5B - 49 CORRIDOR 503 LN5C - 13 LN5C - 12 LN5C - 12 LN5C - 12 LN5C - 15 LN5C - 15 LN5C - 14 LN5C - 17 LN5C - 16 LN5C - 16 LN5C - 17 LN5C - 17 LN5C - 19 LN5C - 18 LN5C - 20 LN5C - 21 LN5C - 21 LN5C - 21 LN5C - 21 LN5C - 57 LN5C - 20 LN5C - 20 LN5C - 20 LN5C - 20 LN5C - 23 LN5C - 25 LN5C - 22LN5C - 22 LN5C - 25 LN5C - 24 LN5C - 26 LN5C - 27LN5C - 27 LN5C - 26 LN5C - 26 LN5C - 29 LN5C - 31 LN5C - 28LN5C - 28 LN5C - 31 LN5C - 31 LN5C - 30 LN5C - 32 LN5C - 32 LN5C - 33 LN5C - 33 LN5C - 35 LN5C - 37 LN5C - 34 LN5C - 34 LN5C - 37 LN5C - 36 LN5C - 38 LN5C - 38 LN5C - 39 LN5C - 39 LN5C - 41 LN5C - 41 LN5C - 41 3 LN5A - 15 LN5A - 61 LN5A - 61LN5A - 61 LN5A - 61 LN5A - 61 LN5A - 61 LN5B - 65 LN5B - 65 LN5B - 65 LN5B - 65 LN5C - 54 LN5C - 54 LN5C - 54 LN5C - 54 LN5A - 33 LN5A - 34 LN5A - 39 LN5A - 39 LN5A - 40 LN5A - 40 LN5A - 45 LN5A - 45 LN5A - 46 LN5A - 46 LN5B - 49LN5B - 46 LN5B - 46LN5B - 43 LN5B - 43 LN5B - 40 LN5B - 40 LN5B - 37 LN5B - 37 LN5B - 34 LN5B - 30 LN5A - 16 LN5A - 16 LN5A - 21 LN5A - 21 LN5A - 27 LN5A - 27 LN5A - 22 LN5A - 22 LN5A - 16 LN5A - 28 LN5A - 28 LN5B - 19 LN5B - 19 LN5B - 16 LN5B - 16 LN5B - 16 LN5B - 16 LN5B - 25LN5B - 25 LN5B - 22 LN5B - 22 LN5C - 31 LN5C - 31 LN5C - 26LN5C - 26 LN5C - 25 LN5C - 25 LN5C - 57 LN5C - 17 LN5C - 17 LN5C - 12 LN5C - 12 LN5C - 37 LN5C - 37 LN5C - 33 LN5C - 33 LLR5 FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-BFCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B FCU-B BSB-5-1FCU-BFCU-BBSB-5-2 FCU-B BSB-5-3 FCU-B FCU-B BSB-5-4 FCU-B FCU-B FCU-B FCU-B FCU-A FCU-BFCU-B FCU-B FCU-B FCU-B FCU-B LN5B - 6,8 2 LN5B - 30 LN5B - 50,52 DS-7 LN5B - 55,57 EWH-11 LN5C - 21 LN5C - 21 6 LN5C - 20 6 EWH-12 LN5C - 38 LN5C - 38 LLR5 - 14 LLR5 - 13 11 GUESTROOM KING 526 GUESTROOM QQ W/ ADA COMM. 528 GUESTROOM KING 530 GUESTROOM KING 525 GUESTROOM KING 524 GUESTROOM KING 523 ADA GUESTROOM QQ 522 ADA COMM. GUESTROOM LUXURY SUITE A 521 GUESTROOM KING 532 GUESTROOM KING 534 GUESTROOM KING 536 GUESTROOM QQ W/BALCONY 538 GUESTROOM QQ 540 CORRIDOR 501 ADA GUESTROOM JUNIOR SUITE 539 GUESTROOM KING 537 GUESTROOM KING 535 GUESTROOM KING 533 GUESTROOM KING W/ ADA COMM. 531GUESTROOM KING 529 GUESTROOM KING 527 HOUSEKEEPING 507 ELEVATOR LOBBY 508 ELEC 506 GUESTROOM KING 520 CORRIDOR 502 GUESTROOM KING 519 GUESTROOM KING 518 GUESTROOM KING 517 GUESTROOM KING 515 GUESTROOM KING 516 GUESTROOM QQ 514 GUESTROOM KING 513 GUESTROOM LUXURY SUITE B 512 GUESTROOM KING STUDIO 511 GUESTROOM KING STUDIO 510 STAIR #1 5ST1 MECH 504 +30"AFF USB +30"AFF USB +30"AFF USB LN5C - 20 +30"AFF USB +30"AFFUSB +30"AFFUSB +30"AFFUSB +30"AFF USB +30"AFFUSB +30"AFF USB LN5C - 32 LN5C - 37 LN5C - 38 LN5B - 29 +30"AFF USB +30"AFF USB +30"AFF USB +30"AFF USB +30"AFF USB +30"AFF USB +30"AFF USB +30"AFF USB +30"AFF USB +30"AFF USB +30"AFF USB +30"AFF USB +30"AFF USB+30"AFF USB+30"AFF USB+30"AFF USB A. SEE SHEET E-000 FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS. B. SEE E-400 SERIES SHEETS FOR ENLARGED PLANS. C. SEE E-500 SERIES SHEETS FOR ELECTRICAL DETAILS. D. SEE E-602 FOR ELECTRICAL CONNECTIONS TO MECHANICAL AND PLUMBING EQUIPMENT SCHEDULE. E. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL INTERCONNECT WIRING FURNISHED BY OTHER TRADES INCLUDING BUT NOT LIMITED TO HVAC, PLUMBING AND KITCHEN. F. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE RAINPROOF AND WEATHER TIGHT. G. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR. USE SOLID CONDUCTOR FOR SIZE #10AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. H. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY INTERIOR DESIGNER. I. ALL RECEPTACLES AND SWITCHES SHALL BE FLUSH MOUNTED UNLESS NOTED OTHERWISE. J. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWING FOR DIMENSIONS, ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE RATED PARTITIONS, CABINET AND CASEWORK DETAILS. K. FINAL DETERMINATION OF FIRE STOPPING REQUIREMENTS SHALL BE BASED ON LOCAL CODE REQUIREMENTS. SEE ARCHITECTURAL COVER SHEET FOR ADDITIONAL INFORMATION. L. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK ON THIS PROJECT. M. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO THE BUILDING LINES. N. SEE E-800 SERIES SHEETS FOR ONE-LINE DIAGRAMS. O. SEE SHEET E-611 FOR ELECTRICAL CONNECTIONS TO KITCHEN EQUIPMENT SCHEDULE. P. VERIFY MOUNTING HEIGHT FOR ALL CLOCK RECEPTACLES WITH INTERIOR DESIGN DRAWINGS PRIOR TO ROUGH-IN. Q. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT. COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. R. FOR ALL FAN COIL UNITS (FCU) INSTALL A THERMAL SWITCH CONNECTION. GENERAL SHEET NOTES DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc EP105 08/27/18 Power Floor Plan Level 5 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 928-1333 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/8" = 1'-0" Power Floor Plan Level 51016'8'4' N SHEET KEYNOTES 1 MOUNT CENTER OF DEVICE AT +5'-0" AFF. VERIFY FINAL LOCATION WITH INTERIOR DESIGNER 2 MOUNT CENTER OF DEVICE AT +6" ABOVE COUNTERTOP BACK SPLASH. VERIFY FINAL LOCATION WITH INTERIOR DESIGNER 3 EXTEND 2-#12, 1-#12 GROUND, 3/4" CONDUIT TO CONDENSER. 4 MOUNT CENTER OF DEVICE +3'-6" AFF. 5 NOT USED. 6 CONNECT TO SWITCH CONTROLLED LIGHTING CIRCUIT. 7 IN WALL ABOVE TOP OF CABINET. TWO (2) DUPLEX RECEPTACLES IN QUAD BACK BOX WITH WHIP MOUNTED AT TOP OF CLOSEST SYSTEM. NO. DATE DESCRIPTION 09/12/2018 ADD #2 1 08/27/2018 Issued for Construction 6 03/22/2019 Revision 8 7 05/15/2019 Revision 10 8 05/31/2019 Revision 12 11 08/02/2019 Revision 15 1111