Loading...
HomeMy WebLinkAboutEP107-Power-Floor-Plan-Level-7-Rev.5T J J J J SJ J J J J J J J J J J J JJ J J J J J JJ J J JJJJ J J J J J 5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 L L 1 1 U U 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE XX SS VV 2 23 3 10 10 22 22 24 24 QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 6.7 6.7 HLR7 HLR7 - 1,3,5 HDPN7 - 13,15,17 HLR7 - 2,4,6HDPN7 LN7 DET-1 WP WP MECHANICAL 702 DWH-1 DWH-2 LN7 - 23 LN7 - 12 WP WP WP WP WP WP WP WP WP WP LN7 - 7 LN7 - 7 LN7 - 14 LN7 - 14 LN7 - 7 LN7 - 7 333 3 3 3 3 WP LN7 - 7 LN7 - 7 2 LN7 - 14 2 2 HN7 - 6 HN7 - 46 6 LLR5 - 16 LLR5 - 17 LLR5 - 15 5 8 8 LN7 - 2,4 DTMV-1 LN7 - 5 LN7 - 17 9 LN7 - 6 LN7 - 6 LN7 - 22 LN7 - 20 LN7 - 24 LN7 - 18 LN7 - 16 EWH-13 ERV-2 ERV-1 CU-3-1 CU-4-1 CU-5-1 CU-6-1 HDPN7 - 1,3,5 HDPN7 - 32,34,36 HDPN7 - 31,33,35 HDPN7 - 38,40,42 HDPN7 - 37,39,41 CU-5-2 CU-6-2 CU-2-1A CU-1-1A CU-3-2 CU-4-2 CU-2-2A HDPN7 - 55,57,59 HDPN7 - 56,58,60 HDPN7 - 62,64,66 HDPN7 - 61,63,65 HDPN7 - 80,82,84 HDPN7 - 67,69,71 HDPN7 - 73,75,77 ERV-4 HDPN7 - 7,9,11 ERV-3 HDPN7 - 8,10,12 CU-5-4 CU-3-4 CU-6-4 CU-4-4 HDPN7 - 19,21,23 HDPN7 - 25,27,29 HDPN7 - 26,28,30 HDPN7 - 20,22,24 CU-3-3 CU-5-3 HDPN7 - 43,45,47 HDPN7 - 49,51,53 HDPN7 - 50,52,54 HDPN7 - 44,46,48 DHWST-2 DHWST-1 DSCU-5 DSCU-6 DSCU-7 DSCU-8 EUH-4 HN7 EF-3 LN7 - 8,10 LN7 - 26,28 CU-4-3 CU-6-3 1 TN5 10 11 LN7 - 3 HDPN7 - 2,4,6 CU-2-2B CU-2-1B CU-1-1B HDPN7 - 79,81,83 HDPN7 - 68,70,72 HDPN7 - 74,76,78 HDPN7 - 68,70,72 EUH-3 ELEV #3 ELEV #1 ELEV #2 A. SEE SHEET E-000 FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS. B. SEE E-400 SERIES SHEETS FOR ENLARGED PLANS. C. SEE E-500 SERIES SHEETS FOR ELECTRICAL DETAILS. D. SEE E-602 FOR ELECTRICAL CONNECTIONS TO MECHANICAL AND PLUMBING EQUIPMENT SCHEDULE. E. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL INTERCONNECT WIRING FURNISHED BY OTHER TRADES INCLUDING BUT NOT LIMITED TO HVAC, PLUMBING AND KITCHEN. F. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE RAINPROOF AND WEATHER TIGHT. G. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR. USE SOLID CONDUCTOR FOR SIZE #10AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. H. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY INTERIOR DESIGNER. I. ALL RECEPTACLES AND SWITCHES SHALL BE FLUSH MOUNTED UNLESS NOTED OTHERWISE. J. REFER TO ARCHITECTURAL AND INTERIOR DESIGN DRAWING FOR DIMENSIONS, ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE RATED PARTITIONS, CABINET AND CASEWORK DETAILS. K. FINAL DETERMINATION OF FIRE STOPPING REQUIREMENTS SHALL BE BASED ON LOCAL CODE REQUIREMENTS. SEE ARCHITECTURAL COVER SHEET FOR ADDITIONAL INFORMATION. L. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK ON THIS PROJECT. M. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO THE BUILDING LINES. N. SEE E-800 SERIES SHEETS FOR ONE-LINE DIAGRAMS. O. SEE SHEET E-611 FOR ELECTRICAL CONNECTIONS TO KITCHEN EQUIPMENT SCHEDULE. P. VERIFY MOUNTING HEIGHT FOR ALL CLOCK RECEPTACLES WITH INTERIOR DESIGN DRAWINGS PRIOR TO ROUGH-IN. Q. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT. COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. R. FOR ALL FAN COIL UNITS (FCU) INSTALL A THERMAL SWITCH CONNECTION. GENERAL SHEET NOTES DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc EP107 08/27/18 Power Floor Plan Level 7 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 928-1333 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/8" = 1'-0" Power Floor Plan Level 71016'8'4' N SHEET KEYNOTES 1 MOUNT ELECTRICAL PANELBOARD(S) TO UNISTRUT STRUCTURE SUPPORTED FROM THE FLOOR AND CEILING. 2 MOUNT CENTER OF DEVICE +4'-0" AFF. 3 SURFACE MOUNT DEVICE TO BACK OF PARAPET. DEVICE CONTROLED BY LC-N 4 DOMESTIC HOT WATER RECIRCULATION PUMPS. VERIFY FINAL LOCATION WITH PLUMBING CONTRACTOR. 5 LOCKABLE DISCONNECT SWITCH FOR ELEVATOR CAB LIGHTING. 6 POWER SUPPLY FOR OWNER FURNISHED SIGNALE. VERIFY FINAL LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. 7 POWER CONNECTION FOR TEMPERATURE CONTROL PANEL VERIFY FINAL LOCATION IN FIELD WITH TEMPERATURE CONTROL CONTRACTOR PRIOR TO ROUGH-IN. 8 DOMESTIC HOT WATER PUMPS. VERIFY FINAL LOCATION WITH PLUMBING CONTRACTOR. 9 POWER SUPPLY FOR EF-3 AND ASSOCIATED CONTROL PANEL. 10 DISCONNECT SERVING LDPN5. SEE SHEET E-801 FOR MORE DETAILS. 11 WEATHER BUG EQUIPMENT RACK NO. DATE DESCRIPTION 1 08/27/2018 Issued for Construction 6 03/22/2019 Revision 8 7 05/15/2019 Revision 10 7 7