Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ET107-Technology-Floor-Plan-Level-7-Rev.5
T S S S H H H H R R R R R R RR R R R R H R R R R RR H S H H HHS S S 5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 L L 1 1 U U 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE XX SS VV 2 23 3 10 10 22 22 24 24 QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 0.9 0.9 6.7 6.71 1 A A E-406 WP WP 1 2 2 CO CO CO 3 A. REFER TO SHEET E-000 FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS. B. SEE E-500 SERIES DRAWINGS FOR ELECTRICAL DETAILS. C. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR DESIGNER. D. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. E. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO BUILDING LINES. F. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. G. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND RAIN TIGHT. H. EACH TELE/DATA OUTLET SHALL HAVE A MINIMUM OF ONE CAT 6 CABLE. A NUMBER DESIGNATION NEXT TO A TELE/DATA OUTLET INDICATES THE QUANTITY OF CAT 6 CABLES PULLED TO RESPECTIVE OUTLET. I. HOUSINGS FOR ALL FIRE ALARM EQUIPMENT SHALL BE WHITE WITH RED LETTERS. J. SEE LOW VOLTAGE DRAWINGS FOR ADDITIONAL WORK. K. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL MEP ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO DUCTS, PIPES, WIRES, CONDUITS, ANCHORS, HANGERS, AND EQUIPMENT.COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. GENERAL SHEET NOTES DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc ET107 08/27/18 Technology Floor Plan Level 7 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 928-1333 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/8" = 1'-0" Technology Floor Plan Level 71 SHEET KEYNOTES 1 EC SHALL STUB WEATHER HEAD THROUGH WALL FOR DATA CABLE SERVING WEATHER BUG SYSTEM. COORDINATE EXACT LOCATION IN THE FIELD. 2 FIRE ALRM SYSTEM SHALL CONTROLL DAMPER IN SHAFT. 3 ROOFTOP IDF CABINET. PROVIDE TELECOM GROUNDING BUSBAR TO SERVE THIS LOCATION. 2" CONDUIT STUBBED TO ROOF. N 0 16'8'4' REVISIONS NO. DATE DESCRIPTION 1 08/27/2018 Issued for Construction 6 03/22/2019 Revision 8 7 05/15/2019 Revision 10 12 09/06/2019 Revision 18 17 10/28/2019 Revision 19 17 17