HomeMy WebLinkAboutF-101-Fire-Suppression-Plans,-Schedules-and-Details-Rev.3DWUP VITREO U S C H I N A U R I N A L B A R D O N K - 4 9 9 1 - E T V I T R E O U S C H I N A U R INALBARDO N K - 4 9 9 1 - E T V I T R E O U S C H I N A U R I N A L B A R D O N K - 4 9 9 1 -ET V I T R E O U S C H I N A U R I N A L B A R D O N K - 4 9 9 1 - E T V I T R E O U S C H I N AURINALBARDO N K - 4 9 9 1 - E T V I T R E O U S C H I N A U R I N A L B A R D O N K - 4 991-ET V I T R E O U S C H I N A U R I N A L B A R D O N K - 4 9 9 1 - E T V I T R E O U S C HINAURINALBARDO N K - 4 9 9 1 - E T V I T R E O U S C H I N A U R I N A L B A R D O N K-4991-ET K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K-4325KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V ITREO U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 KING S T O N B O W L V I T R E O U S C H I N A K - 4 3 2 5 K I N G S T O N B O W L V I T R E O U S CHINAK-4325KING S T O N B O W L V I T R E O U S C H I N A DN 5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 D D F F J J L L P P T T 1 1 Y Y U U A A 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE G G XX SS VV 2 2 3 3 10 10 22 22 24 24 B B QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 0.9 0.9 6.7 6.7 1 2 3 F F FF F2 4 P-401 3 5 5 5 8 8 11 11 12 12 17 17 21 21 23 23 26 26 28 28 30 30 32 32 D D F F J J L L P P T T 1 1 Y Y U U A A 9 9 4 4 18 18 KK N N 7 7 W W 31 31 RR 20 20 16 16 15 15 29 29 27 2725 25 14 14 6 6 13 13 EE G G XX SS VV 2 2 3 3 10 10 22 22 24 24 B B QQ M M ZZ 19 19 C C HH 9.2 9.2 L.5L.5 A.7 A.7 0.9 0.9 6.7 6.7 1 2 3 F FF 2 4 FIRE PUMP SCHEDULE SPECIFICATION SECTION 213000 MARK LOCATION SYSTEM TYPE DESIGN CAPACITY (GPM) DESIGN CAPACITY (PSI) MIN EFF. (%) PUMP MOTOR DATA MANUFACTURER WITH MODEL NUMBER NOTESSUCT. (IN) DISCH (IN)HP RPM VOLTS PH NOTES 1. FIRE PUMP CONTROLLER, FIRETROL MODEL #FTA1930, SOFT START WITH TRANSFER SWITCH. 2. FIRE PUMP SYSTEM, JOCKEY PUMP CONTROLLER; FIRETROL MODEL #FTA550F. 3. CASING WITH 125 LB SUCTION / 125 LB DISCHARGE FF ANSI FLANGES. BACKFLOW PREVENTER SCHEDULE SPECIFICATION SECTION 221300 MARK LOCATION SYSTEM TYPE DESIGN CAPACITY (GPM) PRESS. DROP (PSIG) SIZE (IN) MANUFACTURER WITH MODEL NUMBER NOTES NOTES: 1. PROVIDE WITH GATE OR UL/FM BUTTERFLY VALVES WITH TAMPER SWITCH. 2. MAXIMUM MOUNTING HEIGHT OF 5'-0" ABOVE FLOOR. 3. LEAD FREE. DCDA-1 FIRE PUMP RM 138 MAIN FIRE SERVICE DOUBLE CHECK DETECTOR ASSEMBLY 750 3 6"AMES COLT SERIES 3000SS 1, 2, 3 FP-1 FIRE PUMP RM 138 FIRE PROTECTION HORIZONTAL SPLIT-CASE 750 41 79 5 4 25 1760 460 3 PEERLESS #4AEF11 1, 3 JP-1 FIRE PUMP RM 138 FIRE PROTECTION MULTISTAGE CENTRIFUGAL 9.69 57.97 79 1 1 3/4 3460 460 3 GRUNDFOS # CR 1-6 A-B-A-E-HQQE 2 TYPICAL OS&Y GATE VALVE WITH SUPERVISORY TAMPER SWITCH INDICATING BUTTERFLY VALVE WITH TYPICAL OS&Y GATE VALVE OR SUPERVISORY TAMPER SWITCH TO FIRST FLOOR AUTOMATIC WET PIPE SPRINKLER SYSTEM FULL LINE SIZED BY-PASS PUMP SUCTION HEAD PRESSURE CONTROL VALVE JOCKEY PUMP ON CONCRETE PAD TYPICAL PRESSURE GAUGE FIRE PUMP ON CONCRETE PAD CHECK VALVE (TYPICAL) FIRE DEPARTMENT CONNECTION, SEE CIVIL UTILITY DRAWINGS FOR LOCATION DOUBLE CHECK DETECTOR ASSEMBLY AUTOMATIC BALL DRIP FIRE PUMP TEST HEAD TO WET STANDPIPES EXTERIOR WALL 6" INCOMING FIRE SERVICE POST INDICATING VALVE WITH TAMPER SWITCH WET PIPE ALARM CHECK VALVE ASSEMBLY AND TRIM 3 SYSTEM RISER CAST IRON FLANGE AND SPIGOT PIECE CAST IRON BELL AND SPIGOT PIPE THRUST BLOCKING RODS FIRE SERVICE MAIN RESTRAINT BUILDING SLAB12"GENERAL FIRE NOTES A. REFER TO SHEET M-000 FOR GENERAL SYMBOLS AND ABBREVIATIONS. B. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE AND SHALL CONFORM WITH ALL FEDERAL, STATE AND LOCAL CODES AND STANDARDS. THE SAME ARE MADE A PART OF THESE CONTRACT DOCUMENTS, THE SAME AS IF REPEATED HEREIN. C. CONTRACT DOCUMENTS CONSIST OF BOTH THE PROJECT MANUAL AND DRAWINGS AND BOTH ARE INTENDED TO BE COMPLIMENTARY - ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. D. THE CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. E. CONSTUCTION DOCUMENTS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE, HOWEVER, SYSTEMS HAVE BEEN SHOWN DIAGRAMATICALLY AND IN SOME CASES, ENLARGED FOR CLARITY. ANY OFFSETS, ADDITIONAL FITTINGS AND/OR APPURTENANCES REQUIRED TO PROVIDE A COMPLETE AND COORDINATED SYSTEM SHALL BE BORNE BY THE CONTRACTOR. F. PROVIDE AND INSTALL AUTOMATIC SPRINKLER SYSTEMS AS REQUIRED IN ALL AREAS UNLESS OTHERWISE NOTED. THE FIRE PROTECTION CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND ADJUST HIS WORK ACCORDING TO ANY VARIATIONS OR DEVIATIONS FROM THOSE SHOWN ON THE PLANS. G. THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION OF THE FIRE PROTECTION SYSTEMS AND SHALL CONFORM TO THE NATIONAL FIRE PROTECTION ASSOCIATION CODES (NFPA) STANDARDS AND RECOMMENDED PRACTICES, LATEST EDITIONS ADOPTED BY THE STATE, ALL APPLICABLE STATE AND LOCAL FIRE PREVENTION BUREAU'S STATUTES, CODES AND REQUIREMENTS OF OWNER'S INSURANCE UNDERWRITER. INCLUDE ALL PIPE AND FITTINGS, APPROVED WATER FLOW DETECTING ALARM DEVICES, PRESSURE GAUGES, SPRINKLER HEADS, INDICATING VALVES, FIRE DEPARTMENT CONNECTIONS AND OTHER MATERIALS NEEDED TO PROVIDE A COMPLETE AND OPERABLE CODE COMPLIANT SYSTEM, BASE ON THE DATE OF THE CONSTRUCTION DESIGN RELEASE. H. SPRINKLER PIPING INSTALLATION SHALL BE COORDINATED WITH OTHER TRADES, EQUIPMENT, DUCTWORK, STRUCTURAL STEEL, ELECTRICAL PANELS, RACEWAYS, ARCHITECTURAL DESIGN INTENT; INCLUDING REFLECTED CEILING PLANS AND CEILING TILE DIMENSIONS PRIOR TO INSTALLATION. PIPING NOT COORDINATED MAY NEED TO BE REMOVED AND/OR REPLACED. ANY REMOVAL REQUIRED DUE TO INCOMPLETE COORDINATION, SHALL BE DONE BY THE SPRINKLER CONTRACTOR, ALL COST SHALL BE BORNE BY THE SPRINKLER CONTRACTOR. I. THE FIRE PROTECTION CONTRACTOR SHALL PROVIDE AND INSTALL CEILING ACCESS PANELS FOR ACCESS TO SHUT-OFF VALVES, CONTROL VALVES, DRAIN VALVES, ETC. LOCATED ABOVE NON-ACCESSIBLE CEILINGS. COORDINATE LOCATION OF ACCESS PANELS WITH ARCHITECT/ENGINEER. J. ALL ELECTRICAL AND MECHANICAL ROOMS SHALL BE SPRINKLED WITH HIGH TEMPERATURE SPRINKLER HEADS. K. NO PIPING SHALL BE ROUTED OVER OR THRU ELECTRICAL OR IT CLOSETS, UNLESS IT IS TO SERVICE EQUIPMENT OR DEVICES IN THE SPACE. L. REFER TO THE ARCHITECTURAL LIFE SAFETY PLANS. M. MAINTAIN EGRESS PATH CLEARANCE IN STAIRS. N. WATER FLOW TEST DATA IS THE FIRE PROTECTION CONTRACTORS RESPONSIBILITY TO ENSURE ADEQUACY OF FLOW AND PRESSURE. O. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF ACOUSTICALLY ISOLATED SPACES AND ADDITIONAL REQUIREMENTS. COORDINATE ALL FIRE PROTECTION ITEMS WITH ACOUSTICAL ISOLATION SYSTEMS, INCLUDING BUT NOT LIMITED TO PIPES, WIRES, CONDUITS, ANCHORS, HANGERS AND EQUIPMENT. COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. P. SPRINKLER HEADS SHOWN ARE FOR ARCHITECTURAL INTENT AND BIDDING PURPOSES ONLY. SUCCESSFUL FIRE PROTECTION CONTRACTOR SHALL HAVE THE SPRINKLER HEAD LAYOUT REVIEWED AND APRROVED BY THE ARCHITECT PRIOR TO INSTALLATION. Q. SPRINKLER PLANS SHALL BE PROVIDED PER MARRIOTT'S MODEL 14 WHICH INCLUDE SHOP DRAWINGS, HYDRAULIC CALCULATIONS AND CUT SHEETS. ALL OTHER INFORMATION SHALL BE PROVIDED AS REQUIRED BY NFPA 13, (ex: CEILING DETAILS, LEGENDS, ETC.) INTERMEDIATE STAIR LANDING 2 1/2" FIRE HOSE VALVE WITH CAP AND CHAIN COMBINED SPRINKLER / STAND PIPE RISER INDICATING TYPE FLOW CONTROL VALVE WITH SUPERVISORY SWITCH PRESSURE GAUGE FLOW SWITCH CHECK VALVE STAIR #2 STAIR #1 INTERMEDIATE STAIR LANDING HARD PIPED DRAIN LINE AUXILIARY DRAIN VALVE UNION 1" SIGHT GLASS REMOTE INSPECTORS TEST VALVE STAND PIPE RISER 2 1/2" FIRE HOSE VALVE WITH CAP AND CHAIN 36"±7'-8"±36"±DRAWING NO. DATE CDG PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc ISSUED FOR CONSTRUCTIONF-101 08/27/18 Fire Suppression Plans, Schedules and Details 17089 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 781-6200 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Newmark Design 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 1/16" = 1'-0" Fire Suppression Floor Plan Level 11 1/16" = 1'-0" Fire Suppression Floor Plan Level 22 0 32'16'8' 0 32'16'8' N N NOT TO SCALE Fire Pump Piping Detail3 NOT TO SCALE Fire Service Connection4 SHEET KEYNOTES 1 COMBINATION CLASS I WET STAND PIPE AND SPRINKLER RISER WITH FLOOR CONTROL ZONE VALVES. 2 CLASS 1 WET PIPE RISER. PROVIDE A STAND PIPE RISER CONTROL VALVE PER NFPA 14 WITH SUPERVISORY TAMPER SWITCH. 3 COMBINATION CLASS 1 WET STAND PIPE INSPECTORS TEST AND DRAIN LINE. PROVIDE A STAND PIPE RISER CONTROL VALVE PER NFPA 14 WITH SUPERVISORY TAMPER SWITCH. 4 FIRE DEPARTMENT 2 1/2" VALVE CABINET. 5 PROVIDE SPRINKLERS UNDER THE GRAND STAIRS. NOT TO SCALE Fire Suppression Floor Control Valve with Remote Inspectors Test and Drain Assembly Detail5 REVISIONS NO. DATE DESCRIPTION 1 08/27/2018 Issued for Construction 3 12/03/2018 General Revisions