HomeMy WebLinkAboutG0-02-GENERAL-NOTES,-LEGENDS,-&-ABBREVIATIONS-Rev.3&AND ANGLE @ AT CENTERLINE CHANNEL Ø DIAMETER OR ROUND #NUMBER OR POUND PLATE SF SQUARE FOOT (FEET) ACOUST ACOUSTICAL AD AREA DRAIN ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR ALUM ALUMINUM APPROX APPROXIMATE ARCH ARCHITECTURAL ATTEN ATTENUATION BD BOARD BLDG BUILDING BLKG BLOCKING CJ CONTROL JOINT CLG CEILING COL COLUMN CONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CTR CENTER DBL DOUBLE DIA DIAMETER DIM DIMENSION DN DOWN DR DOOR E EAST EA EACH E ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EQ EQUAL EQUIP EQUIPMENT EXP EXPANSION EXIST EXISTING EXT EXTERIOR FD FLOOR DRAIN FFD FUNNEL FLOOR DRAIN FIN FINISH FL FLOOR FOF FACE OF FINISH FOS FACE OF STUD FR (FRM) FRAME FS FLOOR SINK FT FOOT OR FEET FURR FURRING GA GAUGE GALV GALVANIZED GL GLASS GYP BD GYPSUM BOARD HDW HARDWARE HDW HARDWOOD HM HOLLOW METAL HORIZ HORIZONTAL HT HEIGHT ID INSIDE DIAMETER / DIMENSION IN INCH INFO INFORMATION INSUL INSULATION INT INTERIOR JAN JANITOR JT JOINT L LONG / LENGTH LT (LTG)LIGHT (LIGHTING) LWC LIGHTWEIGHT CONCRETE MAX MAXIMUM MECH MECHANICAL MFG MANUFACTURING MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MTD MOUNTED MTL METAL N NORTH N / A NOT APPLICABLE NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NPS NATIONAL PIPE STANDARD NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER / DIMENSION OVD OVERFLOW DRAIN OH OPPOSITE HAND OPNG OPENING OVHD OVERHEAD OZ OUNCE PL PLATE PLBG PLUMBING PLYWD PLYWOOD POL POLISHED PPT PRESSURE PRESERVATIVE TREATED PR PAIR PT POINT PTD PAINTED QTY QUANTITY R RISER OR RADIUS RCP REFLECTED CEILING PLAN RD PRIMARY ROOF DRAIN RE REFERENCE REINFORCED REINF REINFORCED REQ'D REQUIRED REV REVISION RM ROOM RO ROUGH OPENING RS ROOF SCUPPER AND DOWNSPOUT SD SCUPPER DRAIN SPHD SPRINKLER HEAD SQ SQUARE SS STAINLESS STEEL STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURE / STRUCTURAL SY (SQ YD)SQUARE YARD(S) SHT SHEET SIM SIMILAR SPEC SPECIFICATION T TREAD TEL TELEPHONE TEMP TEMPERED TOD TOP OF DECK TOS TOP OF SLAB OR TOP OF STEEL TOW TOP OF WALL TV TELEVISION TYP TYPICAL UNO UNLESS OTHERWISE NOTED VERT VERTICAL W WEST OR WIDE OR WIDTH W /WITH W / I WITHIN W / O WITHOUT WD WOOD WND WINDOW WT WEIGHT Ð [ COLUMN AND / OR GRID LINES FLOOR PLAN MATCHLINE SYMBOL CENTERLINE SYBMOL / GRID LINE EXPANSION JOINT LOCATION LINES GRAPHIC SCALE SYMBOL NORTH ARROW SYMBOL MATERIAL KEYNOTE SYMBOL SPOT ELEVATION SYMBOL FLOOR ELEVATION LEVEL SYMBOL DETAIL REFERENCE SYMBOLS EXTERIOR BUILDING SECTION SYMBOL BUILDING/WALL SECTION SYMBOL DETAIL SECTION SYMBOL BUILDING ELEVATION SYMBOL INTERIOR ELEVATION/DETAIL SYMBOL A B 16'0 32'8' NORTH PT- 1 0' -0" Level 1 0' -0" DETAIL SHEET NUMBER R 0' - 4" 4" TYPICAL -FOR STUD PARTITIONS (UNLESS NOTED OTHERWISE) 8" TYPICAL - FOR MASONRY PARTITONS & CONCRETE (UNLESS NOTED OTHERWISE) COLUMN PARTITION WHEN ONE JAMB IS LOCATED BY A COLUMN, THE FOLLOWING DIAGRAM APPLIES: INSECTING PARTITION DOOR AS SCHEDULED 4" TYPICAL (UNLESS NOTED OTHERWISE) 3. FOR OPENINGS IN PARTITIONS OR WALLS: -When one occurs at gridline, no dimensions will be shown and width will be established by either criteria or schedules -When neither jamb occurs at a partition intersection, at a column or at a gridline: one jamb will be located dimensionally by the detail. -When one jamb is located by a partition intersection, the following diagram applies: 1. DIMENSIONS WILL NOT BE SHOWN FOR THE FOLLOWING CONDITIONS: -When partition is centered on grid line. -When partition is shown flush with column face. -When partition is shown flush with grid line. When face of partition is centered on glazing mullion. 2. MASONRY / METAL STUD WALLS ARE DIMENSIONED FROM FINISHED FACE. PARTITION All drawings are intended to be complementary. Notify the architect of any dimensioning discrepancy prior to proceeding. Dimensions are to face of concrete and CMU walls (nominal dimensions). Dimensions are to outside face of gypsum board / stud walls. Dimensions are as identified on the documents or as established by criteria as follows: RAILING SYMBOL Rail Type Designation Rail Type Number REVISIONS SYMBOL Area / Item Revised Revision Number ROOM / SPACE IDENIFICATION SYMBOL Room Name Room Number DOOR NUMBER SYMBOL 3B 120 ABBREVIATIONS GRAPHIC SYMBOLS DIMENSIONING CRITERIA 0' -0" FIN. FLR. HT. OR 120 DANCE FLOOR REFERENCES LEGEND WALL SECTION 1 A101 SECTION NUMBER SHEET NUMBER BUILDING SECTION 1 A101 SECTION NUMBER SHEET NUMBER 1 A101 COLUMN GRID LINE A A DETAIL REFERENCE A101 1 SIM DETAIL NUMBER SHEET NUMBER REFERENCE OR DATUM NAME ELEVATION NORTH ARROW INTERIOR ELEVATION A101 1 1 1 1 CENTERLINE SHEET NUMBER DETAIL NUMBER CL REVISION REFERENCE A101 1 1 1 1 SHEET NUMBER DETAIL NUMBER BUILDING ELEVATION CL REVISION CLOUD REVISION NUMBER EARTH AGGREGATE FILL CONCRETE PRECAST CONCRETE BRICK IN PLAN CONCRETE MASONRY UNITS CUT/ CAST STONE STEEL MORTAR NET DISCONTINUOUS ROUGH LUMBER CONTINUOUS LUMBER RIGID INSULATION BLANKET INSULATION GROUT GYPSUM BOARD MARBLE / GRANITE ACOUSITCAL TILE / BOARD WOOD GRAIN PLYWOOD FINISH LUMBER MATERIAL LEGEND GENERAL NOTES 1. Codes: All work shall conform to local building codes, ordanances, and laws having jurisdiction at project site. Refer to applicable codes listed in the Code Summary on sheet G0-03. 2. Dimensions: A. Interior dimensions are to face of wall substrates or to grids, unless noted otherwise. B. Exterior dimensions are to face of stud, face of CMU, or to grids, unless noted otherwise. C. Edge of slab is located 1 inch inside of face of studs, unless noted otherwise. D. Dimensions for Doors and Cased Openings: Door and cased openings that are not dimensioned in the documents shall be located as follows: • Doors and openings in middle of walls shall be centered in the wall. • Doors and openings adjacent to a wall shall be located 6 inches from face of adjacent wall. E. Verify all dimensions and conditions and notify architect of all discrepancies in writing prior to proceeding with work. 3. Contractor Shall Not Scale Drawings: Use dimensions on drawings and actual field dimensions. 4. Building Insulation / Minimum Values: Provide insulation in thickness to achieve those minimum values as described in the adopted energy conservation code for commercial application in the locality of the project: Average thermal resistance 'R' values for exterior walls to be minimum R-7.5ci (continuous insulation) outside sheathing plus R-13 inside wall. Average thermal resistance 'R' values for roof to be minimum R-25ci above roof deck. Average thermal resistance 'R' values forunheated slabs to be minimum R-10for 24" below grade. 5. Support Blocking: Provide FRT blocking in wall and ceilings to support accessories, light fixtures, signage, and graphics. Blocking in contact with concrete may be PPT, otherwise blocking shall be FRT. 6. Overhead Support of Objects: Support overhead objects that are suspended from or attached to overhead surfaces, or attached to floor-mounted structures as required to insure firm and stable installation. Refer to the project manual for guidelines for the attachment of overhead objects and redundant supports. 7. Documents: Civil, Landscape, Structural, Architectural, Mechanical, Plumbing, Electrical, Fire Protection, Interior Design, and Food Service documents are complimentary. Information shown on Architectural documents and not shown on Civil, Landscape, Structural, Mechanical, Plumbing, Electrical, Fire Protection, Interior Design, or Food Service, or shown on Civil, Landscape, Structural, Mechanical, Plumbing, Electrical, Fire Protection, Interior Design, or Food Service and not shown on Architectural drawings shall be interpreted as being shown on ALL documents. Refer to drawings and specifications for included disciplines. 8. Coordination: A. Review and coordinate requirements of the documents before beginning installation of work. Report discrepancies discovered in writing to Architect. requirements indicated on documents shall be corrected by Contractor at no additional cost to the Owner. B. Verify the utility requirements characteristic of operating equipment are compatible with building utilities. Coordinate work of various construction trades having interdependent responsibilities for installing, connecting to, and placing equuipment in service. C. Coordinate space requirements and installation of mechanical and electrical work indicated on drawings. Verify locations and required opening sizes for mechanical equipment, locations and sizes of equipment for pads and bases, and requirement and location of power and water for drain installation with equipment manufacturers beforeproceeding with work. D. Comply with installation requirements of manufacturers instructions and approved shop drawings. 9. Typical Details: In addition to details reference in the drawings refer to alldrawing chapters for typical details which shall be applied as if specifically noted on the drawings for each instance in which they are applicable. This ioncludes, but is not limited to, typical indicated throughout the drawing set. 10. Protection of Finishes: A. Contractor shall protect all concrete slabs intended to become finished floors from wear, damage, and staining until final finish is applied. Then floors shall be protected again until turnover to the owner. B. Contractor shall protect all installed finishes from damage. All finishes damaged during construction shall be corrected by Contractor at no additional cost to the Owner. 11. Ductwork: Contractor shall provide for all mechanical runs openings in walls above ceiling where duct runs interupt wall framing -provide supplemental stud framing or other support to wall framing aropund opening s. Many demolition / repair locations are indicated on plans. However, contractor shall refer to mechanical electrical, plumbing, fire protection and other discipline drawings showing work of trades showing quantity and size of penetrations required. Fire rated walls are required to be sealed / fire stopped in accordance with a tested assembly based on applicable codes. 12. Above Ceilings: Walls above ceilings (not exposed to view) are required to be sealed tight for air and acoustic purposes in addition to fire stopping where fire rated construction exists -penetrations concealed from public view are not required to be finished otherwise. 13. Project Schedule: Contractor shall prepare for owner and architect review, a contract sequence and construction schedule immediately following contract award. Contractor shall report any contradictory schedule information to architect prior to bidding. Refer to the project manual for project final completion date. 14. Hard Surface Flooring: The coefficient of friction for tile and other hard surface flooring shall comply with AcuTest DCOF. 15. Exterior Concrete Surfaces: Shall have a light broom finish, UNO. 16. Food Service Equipment and Installation: Shall comply with the National Sanitation Foundation requirements. Kitchen exhaust hood installations, where indicated on the drawings, shall comply with NFPA 96 and be equipped with an approved dry chemical fire suppression system. 17. All Glazing Materials and Installation: Shall conform to federal, state, and local regulations. See the drawings and specifications for additional information. 18. Fire Suppression: The building shall be equipped with a fire suppression system designed and installed in accordance with NFPA 13 and the requirements of the authority having jurisdiction at the site. Approval shall be obtained from the AHJ prior to submitting shop drawings and design calculations for review. The initial sprinkler submittal shall bear the approval stamp of the AHJ as well as the system designer credentials. 19. Fire Alarm System: The building shall be equipped with a complete fire alarm system designed and installed in accordance with NFPA 72 and the requirements of the authority having jurisdiction at the site. Approval shall be obtained from the AHJ prior to submitting shop drawings and design calculations for review. The initial fire alarm system submittal shall bear the approval stamp of the AHJ as well as the system designer credentials. 20. Through-Penetration Fire Stopping: Is specified in the project manual as a performance specification for the project. All fire stopping shall be provided by the same manufacturerfor the entire project except in the event that a particular condition is not a part of the selected manufacturer's product line. Where this condition exists, the contractor shall advise of the diviation as part of the submittal process. It is the intent that fire stopping materials be of the same color and manufacturer where possible. 21. For Fire Rated System Designs: Indicated on the drawings, the contractor may propose a substitution having the same performance characteristics as that specified for approval if proprietary primary materials prevent open competition for the applicable systems. 22. Penetrations and Openings: Where the drawings indicate recessed lighting devices, alarms, speakers, and other objects resulting in membrane penetrations into the assembly which exceed the size of the openings allowed by a listed system design, the contractor shall provide UL listed fire rated boxes to enclose the penetrating object and provide a code approved listed fire separation assembly as part of the submittal process. The contractor shall provide confirmation from the manufacturers that the proposed products will provide the specified level of fire protection without exceeding any applicable criteriaaffecting the UL system design indicated. 23. Access Panels: The contractor shall provide both fire rated and non-fire rated access panels and other means of access for maintaining building systems provided and installed in this project. Locations and sizes shall be as required to maintain systems and components. For locations not indicated on the drawings, the contractor shall propose, through the submittal process, access panel materials and locations for approval. ADD #2 ADD #2 ADD #2 VICINITY MAP 3 3 3 3 DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright ©GSB, Inc G0-02 08/27/18 GENERAL NOTES, LEGENDS, & ABBREVIATIONS 171528 CARMEL, INCARMEL, IN 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 ISSUED FOR CONSTRUCTION3 ADD #2 3 ADD #2 REVISIONS NO. DATE DESCRIPTION 1 08/27/2018 Issued for construction Date Addendum #7 3 12/03/2018 General Revisions