M1-01A-MECHANICAL-FLOOR-PLAN-LEVEL-1---AREA-A-Rev.2
UPWOMEN148MONON ENTRY143VESTIBULE144MEN147ELEVATOR LOBBY108MONON LOBBY102COLLECTION141MEETING101JAN.158WOMEN104RAMP105COATS & STORAGE107VESTIBULE106VRF-1-01VRF-1-02VRF-1-04EWH-1EWH-2EWH-3EWH-4EDH-1-01LS10-3250LS10-3270LS10-3230LS10-3230LS10-3235LS10-3235LS10-3230LS10-3230LS10-323018"x10"16"x10"10"LS10-3315LS6-1115LS6-1110LS8-22056"6"6"LS10-3280SD6105SD6105LS6-11056"6"6"558111112172121LLPT11YYUU1818NN7WWRR201515146X223MMZZ19199.29.2L.56.7LR4LR4LR4LR4LR48"10"LS8-29010"10"10"LR3LS10-3250LS10-3250LR416"x12"16"x12"10"10"10"LS8-220510"10"10"10"10"10"x10"10"10"LR3LR3SG1125SG11254"14"x8"14"x12"10"8"8"SD81558"8"EG111010"8"ABOVEBELOW8"10"10"8"8"10"EG1110EG1110EG1110EG1120EG1120EG1110EG1110EG1110EG1110EG1160EG1160EG1160EG17514"x12"14"x12"12"12"20"x12"20"x12"20"x12"14"x12"10"20"x12"8"8"8"8"8"8"8"8"6"6"8"6"8"8"8"RDDR26"x10"26"x10"12"x10"28"x20"22"x16"16"x12"28"x22"RG412M5-012M5-012M5-011111112M5-0111112M5-01111630"x10"R4266624510"3314"x10"RG41LR1LR1LR1LR1FDVRF-1-03888GENERAL NOTES:1. REFER TO M0-01 FOR ADDITIONAL GENERAL NOTES.2. REFER TO PIPING PLANS FOR THERMOSTAT LOCATIONS.3. REFER TO M6-01 FOR VRF PIPE SIZES.4. REFER TO M0-01 FOR INSULATION NOTES.DRAWING NO.DATEGSB PROJECT NO.DRAWING TITLE3555 NW 58TH StreetSuite 700-WOklahoma City, OK 73112T: 405.848.9549F: 405.848.9783www.gsb-inc.comCopyright ©GSB, Inc M1-01A03/22/19MECHANICAL FLOOR PLANLEVEL 1 - AREA A171528CARMEL, INCARMEL, INHOTELCARMICHAELAT CITYCENTER2018ARCHITECTGSB, INC3555 NW 58th Street, Suite 700WOklahoma City, OK 73112405 / 848-9549CIVIL ENGINEERCircle Design Group9229 Delegates Row, Suite 150Indianapolis, IN 46240317 / 706-2075STRUCTURAL ENGINEERStructurePoint7260 Shadeland StationIndianapolis, IN 46256317 / 547-5580MEP ENGINEERDEEM6831 E. 32nd Street, Suite 200Indianapolis, IN 46226317 / 860-2990INTERIOR DESIGNERHBA Hirsch Bedner Associates171 17th Street NW, Suite 600Atlanta, GA 30363404 / 873-4379FOOD SERVICE CONSULTANTRicca Design Studios5325 South Valentia WayGreenwood Village, CO 80111303 / 928-1333NORTH 1/4" = 1'-0"M1-01A1MECHANICAL FLOOR PLAN LEVEL 1 - AREA A# PLAN NOTES:1 SEAL DUCT PENETRATION THROUGH SOUND RATED PARTITION PER DETAIL15/M5-01.2 OPEN END OF FAN COIL UNIT RETURN DUCT TO BE COVERED WITH A 2" MERV 8FILTER. FILTER TO BE FASTENED TO DUCT IN A MANNER THAT FACILITATESREMOVAL AND REPLACEMENT OF FILTER. TYPICAL OF ALL FIRST AND SECONDFLOOR FAN COIL UNITS.3 INTERNALLY MOUNTED CABLE OPERATED DAMPER EQUAL TO "DURODYNECODR08". POSITION ADJUSTMENT CABLE JUST BEHIND FACE OF DAMPER.4 PROVIDE DAMPER AT OUTDOOR AIR CONNECTION TO FAN COIL UNIT RETURNAIR PLENUM, TYPICAL.5 UNDERCUT DOOR 1".6 MANUAL BALANCE DAMPER NOT REQUIRED IN SUPPLY BRANCH DUCT TO SLOTDIFFUSER. AIRFLOW TO BE BALANCED BY A MANUFACTURER SUPPLIED, CABLEOPERATED DAMPER KIT, TYPICAL OF ALL SLOT DIFFUSERS. REFER TO GRILLES,REGISTERS AND DIFFUSERS SCHEDULE.NO. DATE DESCRIPTION4 05/29/2019 VRF REVISIONS8 12/10/2019 MISC. CHANGES