HomeMy WebLinkAboutM1-01B-MECHANICAL-FLOOR-PLAN-LEVEL-1---AREA-B-Rev.1CAN 154 RECYCLING 153 STAIR #1 1ST1 HOTEL KITCHEN 140 RESTAURANT & BAR 145 PRIVATE DINING 152 COLD STOR 151 VESTIBULE 150 DRY STOR 149 COVERED DINING 146 SECURITY 133 EAC-1 EUH-2EUH-1 EPUH-1 EF-1 VRF-1-18 VRF-1-19 VRF-1-20 VRF-1-21 VRF-1-22 EWH-5 EDH-1-22 EDH-1-21 SD8 200 RG3RG3 16"x4" 26"x18" 18"x16"18"x16"LS10-3 365 LS10-3 365 LS10-3 365 26"x18" LS10-4 375LS10-4 375 LS10-4 380 LS10-3 270 LS10-3 270 LS10-3 270 LS10-3 270 LS10-3 270 LS10-32805 11 11 12 21 21 23 23 D D F F J L L 1 1 A A 94 18 187 201615 15 13 E G G 2 2 3 3 10 22 24 B B M 19 19 C H 9.2 L.5 A.7 EG1 75EG1100 6" 8" 6"10"SD10 350 SD10 350 SD10 350 8"x8" 10"14"20"x10" LR5LR5 LS10-3 350 10"10"12"10"16"x12"16"x12"10" 18"x14"10"12"12"12"10" LR3 LR3 10"16"x12"16"x12"10"10"LR3LR3 LR3LR3 LR3LR3 SD10 350 SD10 350 SD8 155 20"x8" 8" 8" 26"x8" LS10-3 350 18"x14"18"x14"10"16"x12"10"10"12"x8"16"x12"12"x8" 18"x14"18"x14" 8" 10"26"x18"SD10 350 SD10 350 SD10 350 SD10 350 SD10 350 16"x28" 10" 18"x10"28"x12"28"x12"10"14"x12"14"x12"16"x28" 18"x16" 16"x12"12"10"16"x28" 10" 10"x8" 30"x14" 28"x12"30"x14"30"x14"28"x12"28"x12"28"x12"28"x12"28"x12"26"x8"28"x12"18"x16"30"x12" 30"x14"30"x14"16"x12"10"x8"10"x8"10"10"14"x10" 22"x12" 26"x18" 10"10"30"x12"22"x12"30"x14" 10"10"10" EG1 110 RR RDD DD 10" 10"10" 10"10"10"8"8"ABOVE BELOW 18"x14" 8" R 8" 24"x16" RG4 RG4 2 M5-01 1 1 1 1 1 1 1 1 1 22"x10" 7 8 7 5 5 6 9 10 11 12 13 22"x10" L-2 18"x14"18"x14" 30"x10"30"x10" RG4 2 2 4 3 3 2 14"x10"10"x8"RG3 GENERAL NOTES: 1. REFER TO M0-01 FOR ADDITIONAL GENERAL NOTES. 2. REFER TO PIPING PLANS FOR THERMOSTAT LOCATIONS. 3. REFER TO M6-01 FOR VRF PIPE SIZES. 4. REFER TO M0-01 FOR INSULATION NOTES. DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M1-01B 03/22/19 MECHANICAL FLOOR PLAN LEVEL 1 - AREA B 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NORTH 1/4" = 1'-0"M1-01B 1 MECHANICAL FLOOR PLAN LEVEL 1 - AREA B # PLAN NOTES: 1 SEAL DUCT PENETRATION THROUGH SOUND RATED PARTITION PER DETAIL 15/M5-01. 2 OPEN END OF FAN COIL UNIT RETURN DUCT TO BE COVERED WITH A 2" MERV 8 FILTER. FILTER TO BE FASTENED TO DUCT IN A MANNER THAT FACILITATES REMOVAL AND REPLACEMENT OF FILTER. TYPICAL OF ALL FIRST AND SECOND FLOOR FAN COIL UNITS. 3 OPEN END OF FAN COIL UNIT RETURN DUCT TO BE COVERED WITH A 2" MERV 8 FILTER. FILTER TO BE FASTENED TO DUCT IN A MANNER THAT FACILITATES REMOVAL AND REPLACEMENT OF FILTER. TYPICAL OF ALL FIRST AND SECOND FLOOR FAN COIL UNITS. 4 INTERNALLY MOUNTED CABLE OPERATED DAMPER EQUAL TO "DURODYNE CODR08". POSITION ADJUSTMENT CABLE JUST BEHIND FACE OF DAMPER. 5 DISHWASHER EXHAUST DUCT DOWN TO EXHAUST CONNECTION AT COMMERCIAL DISHWASHER. PROVIDE BALANCE DAMPER AT DISHWASHER EXHAUST CONNECTION. EXTEND DUCT ABOVE CEILING PRIOR TO TRANSITIONING TO HORIZONTAL. 6 ALUMINUM DISHWASHER EXHAUST DUCT TO EXHAUST FAN. REFER TO SHEET M4-03 FOR CONTINUATION. 7 PROVIDE BALANCE DAMPER AT KITCHEN HOOD MAKE-UP AIR CONNECTION, TYPICAL. 8 INSULATE MAKE-UP AIR DUCT WITH 1-1/2" FIBERGLASS BLANKET WITH FSK FACING, TYPICAL. 9 INSTALL KITCHEN HOOD GREASE EXHAUST DUCTS WITHOUT DIPS OR TRAPS THAT MAY HOLD GREASE. SLOPE EXHAUST DUCT A MINIMUM OF 2 PERCENT TO DRAIN GREASE BACK TO HOOD. 10 INSTALL FIRE RATED ACCESS PANEL ASSEMBLIES IN KITCHEN HOOD EXHAUST DUCT AT EACH CHANGE IN DIRECTION AND AT MAXIMUM INTERVALS IF 12 FEET IN HORIZONTAL DUCTS. LOCATE ACCESS PANEL ON TOP OR SIDE OF DUCT. PANEL SHALL BE A MINIMUM OF 12"x12" AND SHALL BE LOCATED 1-1/2" FROM BOTTOM OF DUCT. 11 CLEANOUTS SHALL BE INSTALLED IN HORIZONTAL GREASE DUCT AND SHALL BE PLACED NOT MORE THAN 20 FEET FROM ANY CHANGE IN DIRECTION GREATER THAN 45 DEGREES. DO NOT LOCATE CLEANOUT ON BOTTOM OF DUCT. 12 GREASE EXHAUST SHALL BE ENCLOSED FROM THE POINT AT WHICH IT PENETRATES THE CEILING TO THE OUTLET AT THE EXHAUST FAN. THE DUCT ENCLOSURE SHALL BE EITHER FIELD APPLIED OR FACTORY BUILT. 13 GREASE EXHAUST SHALL BE WELDED 16 GUAGE BLACK STEEL OR OTHER CODE APPROVED MATERIAL. NO. DATE DESCRIPTION