Loading...
HomeMy WebLinkAboutM1-01C-MECHANICAL-FLOOR-PLAN-LEVEL-1---AREA-C-Rev.1DWSB SB SB PRIVATE DINING 111 RECEPTION 109 JANITOR 137 SERVICE 136 ? ? MEN'S LOCKER 134 FEINSTEIN'S CLUB 110 UNISEX TLT 116 GREEN 115 SERVICE 114 VESTIBULE 113 CORRIDOR 120 MDF 123 BREAK ROOM 125 STAIR #2 1ST2 CORRIDOR 122 CLUB OFFICE 119 OFFICE 117 CHEM 159 CLUB STOR 124 HK STORAGE 160 HOUSEKEEPING 118 BAR 112 ELEC 156 EMER POWER 155 FIRE PUMP 138 HR 126 CORRIDOR 121 CLEAN 127 SOILED 128 WORK 131 HOLDING 132 SECURITY 133 SALES 130 SALES 129 CORRIDOR 139 DS-3 DS-2 DS-1 EAC-1 VRF-1-04 VRF-1-08 VRF-1-05 VRF-1-06 VRF-1-07 VRF-1-09 VRF-1-10 VRF-1-11 VRF-1-12 VRF-1-13 VRF-1-14 VRF-1-15 VRF-1-16 VRF-1-17 EWH-6 EWH-14 EWH-7 EWH-8 SD8 120 SD8 120 RG3 RG3 SD6 100 SD8 165 SD8 150 SD6 80 SD6 50 RG3 SD6 90 EG3 100 LS10-3 280 LS10-3 280 SD8 155 SD8 155 RG3 SD10 315 RG3 SD10 315 SD6 50 SD8 200 SD6 100 SD6 100 RG3RG3 RG3 SD8 135 SD6 50SD650 RG3 RG3 SD6 95 SD6 120 SD8 135 LS8-2 150 LS8-2 150 LS8-2 150 LS8-2 170 LS8-2 170 LS8-2 170 LS8-2 170 LS8-2 160 LS8-2 165 SG1 185 SG1 185 LS8-2 180 LS8-2 180 LS8-2 180 LS8-2 180 LS8-2 165 LS6-1 125 SD6 20 21 21 23 23 26 26 28 28 30 30 32 32 L L Y Y U U K N N W W 31 31 RR 29 29 27 2725 25 X S V 22 24 Q M ZZ H RG3 EG3 120 6" 6" 8" 8" 6" 8"10"12"6" 8" 10" 8" 8" 12"x12"10"SD8 155 20"x8" 8" 8"12"12"8" 8"8"12"8"12"x10"6" 6" 6" 6"6"8" 12"x10"12"x10" 10" 8" 8" 10" 4" 10" 8" 8" 8"8"12"x12"16"x12"12"12"8"8"10"10"8"8"10"10" 10"12"8" 8" 8" 8" 8" 8" 8"12"6" 6" 6" 6" 8" 8" 30"x20" 20"x14" 30"x20" 8" 26"x18" 6"30"x18"8" 6" 6" 30"x18"14"x8"26"x18" 4" 28"x16"14"x8"6" 30"x18" 6" 28"x16"28"x16"24"x14"24"x14" 8"4"24"x14"18"x14"18"x14" 14"x12" 14"x12" 4" SD8 155 10" 8" 8" EG3 200EG3200 EG3 75 EG3 150 8" 24"x16" 24"x16" 24"x16" 8" 8" 24"x16" 22"x12"20"x12"12"x12"22"x12"R 6"x6" 8"x6" 14"x12" 12"x10" 1 2 M5-01 2 M5-01 2 M5-01 1 1 1 1 1 1 1 1 1 2 M5-01 1 1 1 1 1 1 1 1 1 1 2 310"EG3 110 6 4 RG3 RG4 8 24"x20" RG4 LR4 LR4 LR4 7 RG4 5 5 8"8"7 12"6 44 RG3 6 RG1 50SG250 RG4 1 11 4 8 6" RG4 24"x20"22"x10"LR1 LR1 LR1 LR1 7 10"FD FD 2 M4-03 GENERAL NOTES: 1. REFER TO M0-01 FOR ADDITIONAL GENERAL NOTES. 2. REFER TO PIPING PLANS FOR THERMOSTAT LOCATIONS. 3. REFER TO M6-01 FOR VRF PIPE SIZES. 4. REFER TO M0-01 FOR INSULATION NOTES. DRAWING NO. DATE GSB PROJECT NO. DRAWING TITLE 3555 NW 58TH Street Suite 700-W Oklahoma City, OK 73112 T: 405.848.9549 F: 405.848.9783 www.gsb-inc.com Copyright © GSB, Inc M1-01C 03/22/19 MECHANICAL FLOOR PLAN LEVEL 1 - AREA C 171528 CARMEL, INCARMEL, IN HOTEL CARMICHAEL AT CITY CENTER 2018 ARCHITECT GSB, INC 3555 NW 58th Street, Suite 700W Oklahoma City, OK 73112 405 / 848-9549 CIVIL ENGINEER Circle Design Group 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317 / 706-2075 STRUCTURAL ENGINEER StructurePoint 7260 Shadeland Station Indianapolis, IN 46256 317 / 547-5580 MEP ENGINEER DEEM 6831 E. 32nd Street, Suite 200 Indianapolis, IN 46226 317 / 860-2990 INTERIOR DESIGNER HBA Hirsch Bedner Associates 171 17th Street NW, Suite 600 Atlanta, GA 30363 404 / 873-4379 FOOD SERVICE CONSULTANT Ricca Design Studios 5325 South Valentia Way Greenwood Village, CO 80111 303 / 928-1333 NORTH 1/4" = 1'-0"M1-01C 1 MECHANICAL FLOOR PLAN LEVEL 1 - AREA C # PLAN NOTES: 1 SEAL DUCT PENETRATION THROUGH SOUND RATED PARTITION PER DETAIL 15/M5-01. 2 PROVIDE FIRE DAMPER AND DUCT ACCESS PANEL WHERE DUCT PENETRATES BOTTOM OF CHASE. 3 VRF CONTROL AND ADAPTER PANELS. 4 OPEN END OF FAN COIL UNIT RETURN DUCT TO BE COVERED WITH A 2" MERV 8 FILTER. FILTER TO BE FASTENED TO DUCT IN A MANNER THAT FACILITATES REMOVAL AND REPLACEMENT OF FILTER. TYPICAL OF ALL FIRST AND SECOND FLOOR FAN COIL UNITS. 5 INTERNALLY MOUNTED CABLE OPERATED DAMPER EQUAL TO "DURODYNE CODR08". POSITION ADJUSTMENT CABLE JUST BEHIND FACE OF DAMPER. 6 PROVIDE DAMPER AT OUTDOOR AIR CONNECTION TO FAN COIL UNIT RETURN AIR PLENUM, TYPICAL. 7 MANUAL BALANCE DAMPER NOT REQUIRED IN SUPPLY BRANCH DUCT TO SLOT DIFFUSER. AIRFLOW TO BE BALANCED BY A MANUFACTURER SUPPLIED, CABLE OPERATED DAMPER KIT, TYPICAL OF ALL SLOT DIFFUSERS. REFER TO GRILLES, REGISTERS AND DIFFUSERS SCHEDULE. 8 BALANCE EXHAUST DUCT TO 750 CFM TO BE PULLED FROM CEILING PLENUM. COVER DUCT OPENING WITH HEAVY DUTY WIRE MESH. NO. DATE DESCRIPTION